19
TIME-OF-DAY
BE SURE TO SET THE TIME-OF-DAY
Setting the time-of-day is important for determining filtration times and
other background features. “Set Time” will appear on the display if no
time-of-day is set in the memory. On the Settings Screen, select the
Time-of-Day line. On the Time-of-Day screen, simply select the Hour,
Minutes, and 12/24 Hour segments. Use the Up and Down Buttons to
make changes.
NOTE:
This only applies to some systems: If power is interrupted to the system,
Time-of-Day will be maintained for several days.
ADJUSTING FILTRATION
MAIN FILTRATION
Using the same adjustment as Setting the Time, Filter Cycles are set
using a start time and a duration. Each setting can be adjusted in 15-
minute increments. The panel calculates the end time and displays it
automatically.
FILTER CYCLE 2 - OPTIONAL FILTRATION
Filter Cycle 2 is OFF by default. This displays as “No”. When Filter Cycle
2 is ON it displays as “Yes”. Press “Yes” or “No” to toggle Filter Cycle 2
ON or OFF. When Filter Cycle 2 is ON, it can be adjusted in the same
manner as Filter Cycle 1. It is possible to overlap Filter Cycle 1 and Filter
Cycle 2, which will shorten overall filtration by the overlap amount.
OWNER’S MANUAL
2017
CIRCULATION PUMP MODES
Some spas may be manufactured with Circ Pump settings that allow
programming filtration cycle duration. Some circ Modes are pre-
programmed to operate 24 hours a day and are not programmable. Refer
to the spa manufacturer’s documentation for any Circ Mode details.
PURGE CYCLES
In order to maintain sanitary conditions, as well as protect against freez-
ing, secondary water devices will purge water from their respective
plumbing by running briefly at the beginning of each filter cycle. If the
Filter Cycle 1 duration is set for 24 hours, enabling Filter Cycle 2 will
initiate a purge when Filter Cycle 2 is programmed to begin.
THE MEANING OF FILTER CYCLES
1. The heating pump always runs during the filter cycle*
2. In Rest Mode, heating only occurs during the filter cycle
3. Purges happen at the start of each filter cycle
For example, if your spa is set up for 24/hour circulation except for shut-
ting off when the water temperature is 3˚F/1.3˚C above the set
temperature, that shutoff does not occur during filter cycles.
ADDITIONAL SETTINGS
LIGHT CYCLE OPTION
If Light Cycle does not appear in the Settings Menu, the Light Timer fea-
ture is not enabled by the manufacturer. When available, the Light Timer
is OFF by default. The settings can be edited the same way that Filter
Cycles are edited.
INVERT PANEL
Selecting Invert Panel will flip the display and the buttons so the panel
can be easily operated from inside or outside the hot tub.