background image

Product Care 

To insure you receive the maximum benefit from using this product, observe 
these guidelines: 

Repair 

- Do not attempt to repair the product or modify the circuitry

by yourself. Please contact CO2Meter directly if the product needs
servicing, including the replacement or calibration of the sensor.
Contact 

[email protected]

 for further information.

Cleaning 

- Disconnect the power before cleaning. Use a damp

cloth. Do not use liquid cleaning agents such as benzene, thinner or
aerosols, as these will damage the device.

Maintenance 

– We recommend testing the communication between

the SEU and RDU under ‘DIAG” function. If these five LEDs blink
and the buzzer of SEU and RDU sound simultaneously, it indicates
that SEU and RDU work normally.

d. 

Safety Notes 

Warning: Your safety is very important to us. To ensure to use the product 
correctly and safety, please read these warnings and the entire User 
Manual before using the product. Otherwise, the protection provided by 
the equipment may be impaired. These warnings provide important safety 
information and should always be observed. 

1.

Please handle the device carefully; do not subject the product
to impact or shock. Otherwise, this may cause the accuracy
drift.

2.

Do not place the unit near a heat source. Heat can cause distortion of
the unit, which may result in an explosion or fire.

3.

Do not touch the exposed electronic circuitry of the device under any
circumstances, as there is the dangerous of electric shocks.

4.

Please take care of cable connection between SEU and RDU. Make
sure the cable from SEU is connected into the INPUT port of RDU.

5.

Please ensure the external power supply is normally supplied to
ventilation fan while  the relay is working. If there has no normally
power supply to the fan, the relay will not work, which may result in
potential danger with lower O2 concentration in confined space

Содержание RAD-0102-6

Страница 1: ...nd monitors enclosed areas for higher than normal levels of carbon dioxide gas If a CO2 leak occurs visible and audible alarms will sound on the sensor unit and on the remote display to warn you and your employees The RAD 0102 6 Remote Storage Safety 3 Alarm is cost effective and has many features Separate SEU Main Sensor Unit and RDU Remote Display Unit allow you to see warning before entering an...

Страница 2: ...the wall adapter mount the sensor unit close to a wall outlet Make sure it is mounted an area that it will not accidently get hit by boxes or heavy machinery 4 Attach one end of the ethernet cable to the SEU Sensor Unit then slide the Sensor Unit onto the mounted bracket on the wall 5 Plug in the wall adapter the SEU Sensor Unit should automatically turn on and perform a self check 6 Securely atta...

Страница 3: ...that came with the device on the wall directly next to the RDU The signs should be visible Perform a Test 1 To test if the monitor is operating correctly you can do a simple test Normal Indoor Air Quality Levels are between 400 1200ppm 2 To test the device simply blow huff on the hole located on the left top corner of the SEU Your exhaled breath is about 3 CO2 which is more than enough to set off ...

Страница 4: ...ed for offsite CO2 monitoring 3 In the case of a power outage the 6VDC Battery Backup can be installed to retain the alarm settings 4 If you have more than one door in the CO2 Storage Area you can also purchase additional display units up to three RDU s can be displayed to a main SEU unit up to a maximum of 300 ft Installation Example ...

Страница 5: ...ve 0 5 5000 ppm for 8 hours Relay 2 is activated by Alarm 2 Alarm 2 can be configured to alarm when CO2 Concentration reaches Alarm 2 Set Point Alarm 2 Set Point can be configured for 0 5 5000 ppm 1 0 1 5 2 0 2 5 3 0 Relay 3 is activated by Alarm 3 Alarm 3 can be configured to alarm when CO2 Concentration reaches Alarm 3 Set Point Alarm 3 Set Point can be configured for 2 0 2 5 3 0 3 5 4 0 The Pea...

Страница 6: ... Relay 1 Normally Closed Contact Output Relay1_COM Relay 1 Common Input Relay1_NO Relay 1 Normally Open Contact Output Alarm 2 controls Relay2 Relay2_NC Relay 2 Normally Closed Contact Output Relay2_COM Relay 2 Common Input Relay2_NO Relay 2 Normally Open Contact Output Alarm 3 controls Relay3 Relay3_NC Relay 3 Normally Closed Contact Output Relay3_COM Relay 3 Common Input Relay3_NO Relay 3 Normal...

Страница 7: ...t correctly and safety please read these warnings and the entire User Manual before using the product Otherwise the protection provided by the equipment may be impaired These warnings provide important safety information and should always be observed 1 Please handle the device carefully do not subject the product to impact or shock Otherwise this may cause the accuracy drift 2 Do not place the uni...

Страница 8: ...anty starting from the date the monitor was shipped to the buyer For more information visit our website www co2meter com pages terms conditions Support CO2Meter com 386 256 4910 or 386 256 4910 Technical Support www CO2Meter com CO2Meter Inc 131 Business Center Drive Ormond Beach FL 32174 ...

Отзывы: