2.
NOTE: All the necessary mounting hardware
(screws, mounting brackets, power supply strip) are included.
All you will need is standard screwdriver, for basic installation.
*There are 3 additional universal power plugs included, so as
the system can be installed worldwide.
Installation Steps
1. Choose a suitable location near a wall outlet to install the SEU.
2. To install the SEU (Sensor Unit) start by making a mark about 18
inches off the floor.
(CO2 is heavier than air and will settle at the
floor, first.)
3. Screw the mounting bracket into the wall where you placed your
mark. If you are using the wall adapter, mount the sensor unit close
to a wall outlet.
(Make sure it is mounted an area that it will not
accidently get hit by boxes or heavy machinery).
4. Attach one end of the ethernet cable to the SEU (Sensor Unit), then
slide the Sensor Unit onto the mounted bracket on the wall.
5. Plug in the wall adapter – the SEU (Sensor Unit) should
automatically turn on and perform a self-check.
6. Securely attach the safety strap over the power supply, to ensure it
does not become accidently unplugged.
7. The Green light should appear and show that the SEU (Sensor
Unit) has power.
8. Over the next few minutes, all lights will flash, and resort back to
green. This means the CO2 level is matching the ambient CO2 level
in the room and provide you with a precise, accurate ppm (parts per
million) reading.