9 . 2
T a b o f e r r o r s
Description
Cause
Remedy
Personal
Softwareproblems:
Emergency Stop
Emergency Stop
pressed
Check and unlock the
emergency stop
button
Operator
RF Spindle
Error message
converter / RF spindle
Check RF spindle /
inverter
Professionals
Oil Stand
No oil available
Check and fill storage
tank central
lubrication
Operator
Safety Doors
Doors from the safety
fence are open
Close doors
Operator
Malfunctions and problems with the machine:
Loss of Steps
Travel speed too high
Check the setting in
the software
Operator
Stepper motor no
longer moves
Timing belt torn on
the Z-motor
Replace the timing
belt on the Z-axis
motor
Professionals
Insufficient
lubrication
Check hoses of the
central lubrication,
leakage?
Incorrect lubrication
intervals
Checking the hoses
and distributors of the
central lubrication for
leakage
Adjust lubrication
interval
Professionals
Too much oil
(dripping down
everywhere)
Lubrication intervals
set incorrectly
Adjust lubrication
interval
Professionals
Machine does not
detect reference
switch
Advance of the
reference trip too fast
Setting the guideline
value 50mm/sec in
software
Professionals