Operating instructions
T-Rex N-Serie (Stepper)
CNC-STEP GmbH & Co. KG ▪ Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 54
Support: +49 (0)2831/91021-50
07.03.2022
adjustable needle valve on the nozzle unit. The supply of the cooling medium is also adjusted with a
needle valve on the nozzle unit. With the correct setting, the system works absolutely fog-free.
1.
Pressure Control Valve (Operating pressure 1-2bar)
2.
Solenoid valves for spray air and lubricant
3.
Storage tank for lubricant (1.5l)
4.
Main switch
Fig. 16: Minimum quantity lubrication MDE
The pressure on the container must not exceed 2.0 bar. If necessary, adjust up or down via the
adjusting screw of the pressure display.
The lubrication system can be switched on and off separately via the green main switch.
1.
Air / Lube mixture head
2.
Regulating valve for Air
3.
Regulating Valve Lubrication
4.
Spray nozzle
Fig. 16.1: Nozzle unit and nozzle
The amount of air and lubricant can be adjusted via the regulating valves.
The nozzle is flexible and should be brought as close to the tool as possible.
!!! Please refer to the separate user manual for this system!!!
1
3
2
4
4
2
1
3