17
E. TROUBLESHOOTING
SITUATION
POSSIBLE CAUSE
CORRECTIVE ACTION
Power light is flashing and
service light is on.
Pool water needs salt.
Test salt level of water. Add salt if necessary.
(see chart on page
11)
Cell is clogged or dirty.
Check and clean cell (see page
14
)
Water temperature is low.
Check water temp, if below 60 degrees,
turn system off. See page
14
for details
Insufficient water flow.
• Make sure pump is running.
• Check and correct all valve alignments.
• Dirty filter: follow filter cleaning
procedures
Sensor tab (top of cell) issues.
• Clean off any calcium on sensor tab.
• Make sure there is not an air bubble at
point of sensor tab in cell housing – if
there is, contact your pool professional
or CMP Tech Support.
System does not have green
power light on.
Problem with power to Control Center.
• Check to make sure On/OFF Switch is
on.
• Make sure pump is on.
• Check Circuit Breaker on bottom of
Control Center; if tripped, press rubber
cover to reset.
No AC power to Control Center.
Verify time clock is providing 220 VAC to
Control Center when active (TO BE DONE
BY CERTIFIED POOL PROFESSIONAL, OR
ELECTRICIAN)
Power light is flashing OR
service light is on while
operating on low output
percentage.
Low salt level, dirty cell, damaged cell
blade coatings.
Set the output to “Boost” and then hold
down the upward arrow button until the
polarity lights begin to flash back and forth.
Check to see if power light has stopped
flashing or the service light has turned off.