background image

11

C. INSTALLATION PROCEDURE

MEASUREMENT

RECOMMENDED LEVEL

DETAILS

FREE CHLORINE

1.0 - 3.0 PPM

Recommended level for residential pools to keep chlorine at a proper 

range for sanitization

pH

7.2 - 7.6

High pH reduces sanitizer efficiency. Low pH damages pool surfaces and 

irritates skin and eyes

TOTAL ALKALINITY (TA)

80 - 100 PPM

Protects pH and prevents rapid pH "bounce"

CYANURIC ACID / STABILIZER

30 - 50 PPM

Protects chlorine from destruction by sunlight. Must be added manually 

with salt chlorine systems

CALCIUM HARDNESS

 200 - 400 PPM

Excess calcium can increase scaling problems. Low calcium (soft water) 

can damage surfaces

PHOSPHATES

ZERO

Can deplete free available chlorine 

SALT RESIDUAL

4,000 - 4,500 PPM

Ideal level for chlorine production. Powerclean Salt systems will operate 

at 3,000 - 35,000 PPM

TABLE 3 - WATER BALANCE

POUNDS OF SALT PER GALLON  REQUIRED TO REACH 4,000 - 4,500 PPM

POOL SIZE (GALLONS)

8000 10000 12000 14000 16000 18000 20000 22000 24000 26000 28000 30000 32000 34000 36000 38000 40000

CURRENT POOL SAL

T C

ONCENTRA

TION (PPM)

0

266

334

400

466

533

600

637

733

800

867

933

1000

1067

1113

1200

1267

1335

200

253

315

380

443

507

570

633

697

760

823

887

950

1013

1076

1140

1203

1267

400

240

300

360

420

480

540

600

660

720

780

840

900

960

1020

1080

1140

1200

600

227

283

340

397

453

510

567

623

680

737

793

850

907

964

1020

1077

1135

800

213

266

320

374

427

480

533

587

640

693

747

800

853

907

960

1013

1067

1000

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

950

1000

1200

185

232

280

328

373

420

467

513

560

607

653

700

747

793

840

887

933

1400

171

215

260

305

347

390

433

477

520

563

607

650

693

737

780

823

867

1600

160

198

240

282

320

360

400

440

480

520

560

600

640

680

720

760

800

1800

147

182

220

258

293

330

367

403

440

477

513

550

587

523

660

697

733

2000

133

166

200

234

267

300

333

367

400

433

467

500

533

567

600

633

667

2200

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

2400

107

132

160

188

213

240

267

293

320

347

373

400

427

453

480

507

533

2600

93

116

140

164

187

210

233

257

280

303

327

350

373

397

420

443

466

2800

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

3000

67

84

100

116

133

150

167

183

200

217

233

250

267

283

300

317

333

3200

53

68

80

93

107

120

133

147

160

173

187

200

213

227

240

253

266

3400

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

3600

27

33

40

46

53

60

66

73

80

86

93

100

106

113

120

127

133

3800

13

16

20

23

26

30

33

36

40

43

47

50

53

57

60

63

67

4000

ok

ok

ok

ok

ok

ok

ok

ok

ok

ok

ok

ok

ok

ok

ok

ok

ok

TABLE 4 - SALT ADDITION CHART

Содержание PowerClean Salt Econ

Страница 1: ... POWERCLEAN SALT ECON INSTALLATION INSTRUCTIONS PRODUCT MANUAL ...

Страница 2: ... 5 Generator Cell Installation 10 6 System Start up Balancing 10 D System Operation 12 1 How the Chlorinator Works 12 2 Salt Requirements 12 3 Control Center Operation 13 4 Cold Weather Operation Winterization 14 5 Cell Maintenance How and When to Clean Your Cell 14 E Troubleshooting 16 F Water Care General Guidelines 19 G Parts List 20 IMAGES TABLES IN THESE INSTRUCTIONS page 6 SIZING CHART page ...

Страница 3: ...ed for storage and reassembled to its original integrity NOTICE SAVE THESE INSTRUCTIONS ELECTRICAL HAZARD All Powerclean Salt systems are shipped from the factory wired for 220 Volts To reduce risk of electrical shock make sure all power to pool equipment area is off prior to any installation or removal of Powerclean Salt System components Immediately replace damaged Control Center cord Do not bur...

Страница 4: ...mply with UL1081 Section 53 5 and UL1795 Hydro massage bathtubs Sections 21 1 59 5 and 63 1 and some local electrical codes connect only to a circuit that is protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power sho...

Страница 5: ...be kept clean in order to make a strong seal High water temperatures above 104 degrees 40 degrees C or direct sunlight can cause the cell housing exterior plastic to discolor This is not a warranty claim Follow installation instructions on page 7 for location and mounting of the Control Center Visibly inspect the cell frequently to check and prevent the accumulation of pool debris that for any rea...

Страница 6: ...tes humidity high bather load water features and other environmental factors the maximum pool size should be reduced by at least 30 When modifying any plumbing system it is important to evaluate the total head loss and any impact that head loss may have on the design of an existing plumbing system The following chart will give specific head loss for the Powerclean Salt Cell If you have any questio...

Страница 7: ... install the salt cell installed as the last piece of pool equipment in line on the return to the pool after the heater See illustration 1 on next page b Installing horizontally will ensure the flow sensor remains submerged c If installed vertically the cell cap must be on top d Always use a check valve before the cell to prevent chlorine backflow e All fittings are 2 inch Socket f NONE Do not ins...

Страница 8: ...nd horizontal c IMPORTANT Do not enclose the Control Center in any box d The Powerclean Salt Econ Control Center has two mounting bolts installed at the top back of the unit simply place the head of the pins in the keyhole slots on the wall bracket and allow the unit to hang freely 4 ELECTRICAL INSTALLATION a The Powerclean Salt Econ Control Center is shipped wired for 220V The control center can ...

Страница 9: ...OCEDURE IMAGE 2 BOTTOM OF CONTROL CENTER TIMER CLOCK GROUND 1 2 3 4 PUMP SUB PANEL LINE GROUND 120V AC CONFIGURATION TIMER CLOCK GROUND 1 2 3 4 PUMP SUB PANEL LINE GROUND 220V AC CONFIGURATION IMAGE 3 WIRING BLOCK DIAGRAM ...

Страница 10: ...n Salt Econ Cell Check Valve FLOW FLOW IMAGE 4A HORIZONTAL CELL IMAGE 4B VERTICAL CELL 6 SYSTEM START UP BALANCING a Balance your water chemistry according to the Water Chemistry Parameters Table 3 Add the proper amount of salt and circulate 24 hours before starting the Powerclean Salt Econ b Start system at the 75 Chlorine Output level and operate normally For the first two weeks test the water e...

Страница 11: ...3 1267 400 240 300 360 420 480 540 600 660 720 780 840 900 960 1020 1080 1140 1200 600 227 283 340 397 453 510 567 623 680 737 793 850 907 964 1020 1077 1135 800 213 266 320 374 427 480 533 587 640 693 747 800 853 907 960 1013 1067 1000 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1200 185 232 280 328 373 420 467 513 560 607 653 700 747 793 840 887 933 1400 171 215 260 305 ...

Страница 12: ...ardware outlets NEVER use salt that contains iodine or anti caking agents like YPS which can cause some discoloration of fittings and pool surface finishes d NOTE Do not use rock salt due to its high levels of impurities WHEN TO ADD SALT e Salt level should be checked monthly The salt level should never be allowed to fall below 3 000 PPM f Salt level is lowered through dilution adding fresh water ...

Страница 13: ...in power to system IMAGE 5 OPERATION PANEL SYSTEM POWER UP g Engage Power switch by pressing to On position As the system boots up the lights will flash for about ten seconds The Power light will then remain solid the Chlorine Output lights will display the selected chlorine output level One of the Polarity lights will also illuminate indicating the direction of current h Every six hours of system...

Страница 14: ... system is operating for buildup on the electrodes and the legs attaching the electrodes to the cell base b If there is no buildup there is no need to clean the cell c How often cleaning is required depends on the chemistry of the pool water including the hardness of the water and pH HOW TO CLEAN THE CELL d IMPORTANT Always turn off the pump prior to cleaning the cell The pump and filter system is...

Страница 15: ...15 IMAGE 6 CELL CLEANING WITH TOOL D SYSTEM OPERATION ...

Страница 16: ...ource Take pool water sample to pool professional Loss of salt due to rain or added water Test salt level Add salt using the chart on page 11 Low salt level less than 3 000 PPM System Power light is flashing service light is yellow solid Increase salt level by adding salt according to chart on page 11 Unable to increase chlorine production Cold water low salt level or cell is over calcified Check ...

Страница 17: ...or tab in cell housing if there is contact your pool professional or CMP Tech Support System does not have green power light on Problem with power to Control Center Check to make sure On OFF Switch is on Make sure pump is on Check Circuit Breaker on bottom of Control Center if tripped press rubber cover to reset No AC power to Control Center Verify time clock is providing 220 VAC to Control Center...

Страница 18: ... A 6 Amp resettable circuit breaker is located on the bottom right of the control panel In the event that the circuit breaker trips push on the rubber cover and you will feel it click as it resets Circuit boards may be damaged Contact Tech Support The titanium legs that hold up the cell blades have broken apart from the blades The legs have been eaten away due to corrosive water Contact Tech Suppo...

Страница 19: ...roxides and other alkaline substances found in pool water Alkalinity is defined as the ability of the water to resist changes in pH also known as the buffering capacity of the water Alkalinity keeps the pH from bouncing all over the place TA is often confused with pH which it affects If TA is too low the pH will be difficult to maintain and may cause staining of pool surfaces Total alkalinity shou...

Страница 20: ...CEMENT CELL 1 52000 220 160 20 000 GALLON POWERCLEAN SALT EXTENDED LIFE REPLACEMENT CELL 1 52000 240 160 40 000 GALLON POWERCLEAN SALT EXTENDED LIFE REPLACEMENT CELL 2 52000 200 103 POWERCLEAN SALT ECON CELL HOUSING 52000 200 101 O RING FOR POWERCLEAN SALT MODELS 1 2 Parts not listed in product table are only available as part of a complete assembly ...

Страница 21: ...________________________________ Installation Date _____________________________ Serial Number _______________________________ Model Number ______________________________ Pool Size in Gallons __________________________ CMP Customer Service Tech Support Toll Free 1 800 733 9060 FAX 770 632 7115 support c m p com Warranty Questions RMA c m p com Support Resource Videos Online c m p com resourcecente...

Страница 22: ...22 NOTES ...

Страница 23: ...23 NOTES ...

Страница 24: ...RRING ROAD NEWNAN GA 30265 WWW C M P COM 1118ab CMP Customer Service Tech Support Toll Free 1 800 733 9060 FAX 770 632 7115 support c m p com Warranty Questions RMA c m p com Support Resource Videos Online c m p com resourcecenter ...

Отзывы: