C. INSTALLATION PROCEDURE
Return to Pool
Pump
From Pool
Filter
Heater
Image is not to scale
Powerclean Salt
Econ Cell
Place salt at least 2ft after ozone injection.
Ozone or AOP can also be installed on a
dedicated return line
Check Valve
Check
Valve
DEL Ozone
or AOP
OZONE
INJECTED
IMAGE 1 - INSTALLATION LOCATION
3. CONTROL CENTER INSTALLATION
a. Using the end of the cell cord as a guide, locate a suitable location for the mounting of the Control Center. The Control
Center must be mounted on a noncombustible surface.
b. The wall mounting bracket should be fastened to the wall at a height comfortable for operation. Screws or anchors are
not included. Make sure that the bracket is fastened directly onto concrete with the proper anchoring device or into a
stud in a noncombustible wall surface. Mount the bracket by installing the one screw, and then leveling the bracket, and
installing the other screw, making sure that the mounting bracket is level and horizontal.
c. IMPORTANT: Do not enclose the Control Center in any box.
d. The Powerclean Salt Econ Control Center has two mounting bolts installed at the top back of the unit: simply place the
head of the pins in the keyhole slots on the wall bracket, and allow the unit to hang freely.
4. ELECTRICAL INSTALLATION
a. The Powerclean Salt Econ Control Center is shipped wired for 220V. The control center can be converted to 120V in the
field by a pool professional or certified electrician; a wiring diagram for making the conversion in included with each
system printed on the box.
b. The system is designed to power on ONLY when the primary pump is operating and should be wired to the load side of
the time clock.
c. Ground with an 8AWG bonding wire from the lug (Image 2) on the bottom of the Control Center to a grounding rod (this
is necessary to protect the integrity of the electronic systems).
d. A complete wiring diagram is included on the next page (Image 3)
e. NOTE: If installed with VS Pump, run chlorinator on secondary timer and sync the second timer with run time on VS
Pump. This ensures the system powers on in sync with the pump in low flow situations.