CMC EZTest Скачать руководство пользователя страница 9

 

mDT001 HazMon System Tester Technical Manual /8 

 

CMC INDUSTRIAL ELECTRONICS LTD 
Phone:  (604) 421-4425 Toll Free:  (888) 421-4425  
Fax:  (604) 421-7734 

www.cmciel.com   [email protected]

 

 

The Industry Leader  

 

in HazMon Technology

 

 

The “

UP

” and “

DOWN

” keys can be used to display further information about the sensor’s 

performance. 

If the display indicates “

Sensor Good

”, use the “

DOWN

 key to verify the value being 

returned by the sensor. The tester display

s the sensor’s value in real world units for verification. 

The following table describes the available display starting from the status display described above: 

 

************************************************ Caution ************************************************* 

Only sensors that display the “

Sensor Good

” message and that are displaying the correct reading 

using the real-time display should be used. 

************************************************************************************************************ 

If a sensor is connected that does not provide a valid CMC family code, the sensor may be read, but 
in the real-

time display will show the sensor type “

Unknown

” and the units as “

raw

”. This sensor is 

not a valid sensor for use on a CMC network. 

Key 

Function 

Description 

Down 1 

Real-time display 

The sensor type and real-time value for the sensor are 
displayed in the units suitable for the sensor. Verify the 
sensor’s output using this function. 

Down 2 

Serial number 
display 

The sensor’s serial number is displayed. The serial 
number should agree with the serial number printed on the 
sensor’s label. 

Up 1 

Sensor Power 

The sensor power voltage level is displayed. If this voltage 
is too low it indicates the sensor is drawing excessive 
power. 

Up 2 

Sensor Data Low 

The data low voltage level on the network is displayed. If 
this voltage is too high, the sensor has resistance between 
the green data wire and the red power wire. 

Up 3 

Sensor Data High 

The data high voltage level on the network is displayed. If 
this voltage is too low the sensor has resistance between 
the green data wire and the white common wire. 

Up 4 

Ground Flt Data 

The ground fault leakage voltage on the network is 
displayed. If this voltage is too high the sensor has 
resistance between the metal case and the green wire. 

Up 5 

Ground Flt Power 

The ground fault leakage voltage on the 

power wire

 is 

displayed. If this voltage is too high the sensor has 
resistance between the metal case and the red wire. 

Up 6 

Ground Flt Common 

The ground fault leakage voltage on the 

common wires

 is 

displayed. If this voltage is too high the sensor has 
resistance between the metal case and the white or black 
wires. 

Содержание EZTest

Страница 1: ...HazMon System Tester CMC Intrinsically Safe Sensor Bus mDT001 EZTest HazMon System Tester Document No 11584 Revision A02 January 2013...

Страница 2: ...azMon Technology Table of Contents 1 Overview 3 2 Description of Indicators 4 3 Operation 5 3 1 Using the Menu Control Pushbuttons 6 3 2 Sensor Test 6 3 3 Bus Test 10 3 4 Sensor Emulator 11 3 5 Sensor...

Страница 3: ...l Free 888 421 4425 Fax 604 421 7734 www cmciel com sales cmciel com The Industry Leader in HazMon Technology Revision Notes First Release October 18 2012 Revision A01 January 16 2013 Update to includ...

Страница 4: ...ce and real time output can be verified All information is presented in scaled units to simplify the test results In addition to testing individual sensors the EZTest can be connected to an active CMC...

Страница 5: ...www cmciel com sales cmciel com The Industry Leader in HazMon Technology 2 Description of Indicators Figure 1 Illustration of Indicators There are five control pushbuttons Power Press to turn power on...

Страница 6: ...tester must be powered in Bus Test mode or it will cause the network to fault when connected The system will display two opening messages when power is turned on The tester may display a status messa...

Страница 7: ...network Sensor Emulator Emulate a sensor Sensor Config Configure a sensor Battery Gauge Check remaining battery level Once the function is displayed it is executed by pressing the SELECT pushbutton 3...

Страница 8: ...displayed Message Description Sensor Good The sensor passed all of the tests and is operational This test confirms the electrical interface of the sensor is working properly Use the DOWN key to verif...

Страница 9: ...units suitable for the sensor Verify the sensor s output using this function Down 2 Serial number display The sensor s serial number is displayed The serial number should agree with the serial number...

Страница 10: ...Fault Data Maximum Ground Fault Power Maximum Ground Fault Common Maximum Power Supply Minimum Data Low Maxi mum Data High Maximum mTS01X 40 0 25 0 25 0 25 4 75 0 25 3 85 mRS001 160 0 25 0 25 0 25 4...

Страница 11: ...resent on the network or responding to the poll request only that they are present in the bus converters polling list Individual sensors should be verified using the Sensor Test If Bus Test is selecte...

Страница 12: ...ure starting at the first field interconnect box to isolate portions of the network If the error is corrected when a branch is isolated the problem will be in that branch Continue to the next field in...

Страница 13: ...now indicate the type of sensor being emulated and the value being sent to the host system 7 The UP and DOWN keys can be used to change the value The range of values that can be emulated are dependen...

Страница 14: ...r the display will indicate 6 Once the current configuration of the sensor has been read the display will show the values for the sensors configuration parameters Use the UP and DOWN keys to select th...

Страница 15: ...2 AA batteries that are located in a battery compartment in the rear of the tester The tester will remain active even if the battery indicator drops to 0 The sensor reading may not be accurate if the...

Страница 16: ...cases you do not need to use the tester to locate a bad sensor or wiring on the network The basic branch isolation technique is the easiest and fastest way to locate the fault The sensor test Bus Test...

Страница 17: ...this FIB See chart above for error codes YES Unplug and clean the sensor connector with 99 isopropyl alcohol on both the plug and jack Is the sensor now working correctly Replace sensor and assign the...

Страница 18: ...nd assign the new serial number in WS1 or EZ128 NO YES Does the red LED in the bus converter flash code 2 Is this the last sensor in this FIB YES NO Check CAT5 cable between this FIB and the last for...

Страница 19: ...ut instead of observing the LED s observe the voltage on the blue white and green white pairs Both pairs should have 4 5VDC present with the negative lead on the white wire and the positive lead on th...

Страница 20: ...iel com The Industry Leader in HazMon Technology 6 Specifications Description Characteristic Sensor bus Voltage Current Communications 5 VDC 5 0 mA max CMC Intrinsically Safe Bus Power Supply Battery...

Отзывы: