Configuration for 2-pipe system
Acoustic configuration: compressor soundproofing (SC)
General technical data - Performance
Size
90.4
100.4
110.4
120.4
140.4
160.4
180.4
200.4
220.4
240.4
Cooling
Cooling capacity
1
[kW]
259
275
298
340
385
434
503
545
602
650
Compressor power input
1
[kW]
78,3
85,6
94,6
108
123
137
158
172
188
208
Total power input
2
[kW]
87,9
95,2
104
118
135
150
173
188
204
224
EER
1
-
2,95
2,89
2,86
2,88
2,84
2,90
2,90
2,91
2,95
2,90
Water flow-rate
1
[l/s]
12,4
13,1
14,3
16,3
18,4
20,7
24,0
26,0
28,8
31,1
User side exchanger pressure drops
1
[kPa]
39,8
44,5
44,4
43,4
46,1
45,6
40,0
46,7
43,8
50,9
Cooling capacity (EN14511:2013)
3
[kW]
258
274
297
339
383
433
502
543
600
648
Total power input (EN14511:2013)
3
[kW]
88,8
96,1
105
119
137
151
175
189
206
227
EER (EN 14511:2013)
3
-
2,91
2,85
2,82
2,84
2,80
2,86
2,87
2,87
2,91
2,86
ESEER (EN 14511:2013)
3
-
4,26
4,30
4,32
4,30
4,28
4,42
4,40
4,45
4,44
4,34
Cooling capacity (AHRI 550/590)
7
[kW]
258
273
297
339
382
432
502
544
600
648
Compressor power input (AHRI 550/590)
7
[kW]
78,2
85,6
94,5
108
122
136
157
171
188
208
Total power input (AHRI 550/590)
7
[kW]
87,8
95,2
104
118
134
149
172
187
204
224
COPr
7
-
2,94
2,87
2,86
2,87
2,85
2,90
2,92
2,91
2,94
2,89
IPLV
7
-
4,79
4,82
4,84
4,80
4,78
4,97
4,92
4,97
4,96
4,87
Heating
Heating capacity
4
[kW]
282
311
338
376
424
469
541
598
643
693
Compressor power input
4
[kW]
77,8
86,0
94,0
104
116
130
151
166
184
198
Total power input
2
[kW]
87,3
95,6
104
114
129
143
167
182
199
214
COP
4
-
3,23
3,25
3,26
3,31
3,30
3,28
3,24
3,29
3,23
3,23
Heating capacity (EN14511:2013)
5
[kW]
283
312
340
378
426
471
543
600
646
696
Total power input (EN14511:2013)
5
[kW]
88,5
97,1
105
115
131
145
169
184
202
217
COP (EN 14511:2013)
5
[kW]
3,20
3,22
3,22
3,28
3,26
3,25
3,22
3,25
3,20
3,20
Cooling 100% - Recovery 100%
Cooling capacity
6
[kW]
255
275
305
344
397
442
509
556
612
670
Total recovery heating capacity
6
[kW]
331
357
396
447
513
573
658
720
794
866
Total power input
6
[kW]
76,6
82,6
91,2
103
117
132
150
164
183
197
Global efficiency
8
[kW]
7,65
7,64
7,69
7,66
7,76
7,68
7,80
7,76
7,70
7,79
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission
delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW at specified reference conditions)
1. Data referred to the following conditions: internal exchanger water = 12/7 °C. Entering external exchanger air temperature 35°C. Internal exchanger fouling factor = 0.44 x 10^(-4) m² K/W.
2. The Total Power Input value does not take into account the part related to the pumps and required to overcome the pressure drops for the circulation of the solution inside the exchangers
3. Data compliant to Standard EN 14511:2013 referred to the following conditions: - Internal exchanger water temperature = 12/7°C - Entering external exchanger air temperature = 35°C.
4. Data referred to the following conditions: internal exchanger water = 40/45 °C. Entering external exchanger air temperature = 7°C D.B./6°C W.B. Internal exchanger fouling factor = 0.44 x 10^(-4) m² K/W
5. Data compliant to Standard EN 14511:2013 referred to the following conditions: - Internal exchanger water temperature = 40/45 °C. Entering external exchanger air temperature = 7°C D.B./6°C W.B.
6. Data referred to the following conditions: exchanger water cooling side = 12/7 °C. exchanger water heating side = 40/45°C. Exchanger fouling factor = 0.44 x 10^(-4) m² K/W
7. Data compliant to Standard AHRI 550/590 referred to the following conditions: internal exchanger water temperature = 6,7 °C. Water flow-rate 0,043 l/s per kW. Entering external exchanger air temperature 35°C. Internal exchanger
fouling factor = 0.18 x 10^(-4) m2 K/W
8. Global Efficiency = (Cooling ca Heating capacity) / Total power input
Содержание WSAN-XSC3 MF 200.4
Страница 20: ...20 WSAN XSC3 MF 90 4 240 4 M02M40N15 01 6 4 Configuration for 2 pipe system ...
Страница 45: ...M02M40N15 01 WSAN XSC3 MF 90 4 240 4 45 8 17 Compressor replacement ...
Страница 46: ...46 WSAN XSC3 MF 90 4 240 4 M02M40N15 01 8 18 Exchanger replacement ...
Страница 47: ...M02M40N15 01 WSAN XSC3 MF 90 4 240 4 47 9 Accessories 9 1 Anti vibration mount support ...
Страница 48: ...48 WSAN XSC3 MF 90 4 240 4 M02M40N15 01 ...