WDAT-iL3 250.2-580.2
M04Z40C18-02
12 General technical data - Performance
Acoustic configuration: compressor soundproofing (SC)
Size
250.2
280.2
320.2
360.2
400.2
420.2
440.2
480.2
540.2
580.2
Cooling
Cooling capacity
1
[kW]
558
618
715
804
904
957
1000
1080
1173
1286
Compressor power input
1
[kW]
185
209
232
261
288
327
331
369
390
431
Total power input
2
[kW]
197
223
248
280
310
350
353
396
417
458
Partial recovery heating
capacity
3
[kW]
112
124
142
160
179
193
200
217
234
258
EER
1
-
2,84
2,77
2,88
2,87
2,92
2,74
2,83
2,73
2,81
2,81
Water flow-rate (User Side)
1
[l/s]
26,7
29,5
34,2
38,4
43,2
45,7
47,8
51,6
56,0
61,5
Internal exchanger pressure
drops
1
[kPa]
55
47
43
34
48
54
49
37
45
55
Cooling capacity
(EN14511:2013)
4
[kW]
556
616
712
802
902
954
997
1077
1169
1282
Total power input
(EN14511:2013)
4
[kW]
199
225
251
282
311
353
357
398
421
463
EER (EN 14511:2013)
4
-
2,80
2,74
2,84
2,84
2,90
2,71
2,79
2,71
2,78
2,77
SEER
6
-
4,63
4,57
4,59
4,61
4,68
4,68
4,67
4,72
4,77
4,79
SEPR
7
-
5,24
5,27
5,04
5,20
5,25
5,30
5,30
5,32
5,25
5,23
Cooling capacity (AHRI
550/590)
5
[kW]
555
615
710
799
898
950
986
1077
1159
1270
Total power input (AHRI
550/590)
5
[kW]
196
220
247
279
319
348
350
392
414
454
COPR
5
-
2,84
2,80
2,87
2,87
2,82
2,73
2,81
2,75
2,80
2,80
IPLV
5
-
5,04
5,03
5,01
5,01
5,06
5,12
5,08
5,18
5,20
5,20
1. Data referred to the following conditions: internal exchanger water = 12/7 °C. Entering external exchanger air temperature 35°C. Evaporator fouling factor = 0.44 x 10^(-4) m2 K/W.
2. The Total Power Input value does not take into account the part related to the pumps and required to overcome the pressure drops for the circulation of the solution inside the exchangers.
3. Recovery exchanger water=40/45°C
4. Data compliant to Standard EN 14511:2013 referred to the following conditions: internal exchanger water temperature = 12/7°C. Entering external exchanger air temperature = 35°C
5. Data compliant to Standard AHRI 550/590 referred to the following conditions: internal exchanger water temperature = 6,7 °C. Water flow-rate 0,043 l/s per kW. Entering external exchanger air temperature 35°C. Evaporator
fouling factor = 0.18 x 10^(-4) m
2
K/W
6. Data compliant to Standard EN 14825:2016
7. Data compliant according to EU regulation 2016/2281
Содержание WDAT-iL3 250.2
Страница 9: ...M04Z40C18 02 WDAT iL3 250 2 580 2 9 3 5 AxiTop...
Страница 39: ...M04Z40C18 02 WDAT iL3 250 2 580 2 39 8 16 Compressor replacement...
Страница 41: ...M04Z40C18 02 WDAT iL3 250 2 580 2 41...
Страница 42: ...42 WDAT iL3 250 2 580 2 M04Z40C18 02...
Страница 43: ...M04Z40C18 02 WDAT iL3 250 2 580 2 43...
Страница 57: ...57 Page intentionally left blank...