Since during the operating the air-conditioner sucks
up and causes a light vacuum in the room, the con-
densation outlet pipe can suck up from the pilge or
the special tank unpleasant smells that can spread in
the cabin. To avoid this possibility, it is possible to
create a siphon (A) as you can see in the picture 1.9
to stop the air.
To check the actual effi-
ciency of the condensa-
tion outlet, pour some
water in the basin.
3.8 - AIR FILTER
The air-conditioner sucks up the ambient air through an air-refrigerating gas exchanger endowed with many
aluminium tongues. They would soon become obstructed because of powder and filth. That’s why you can
mount the air filter directly on the exchanger (as you can see in the picture). The filter must be easily taken off
to clean or replace it.
3.7 - CONDENSATION OUTLET
3 INSTALLATION OF THE COMPONENTS
A
A