5 ELECTRICAL CIRCUIT
5.7 - MULTIPLE INSTALLATION
The CABIN air-conditioner fits perfectly in multiple installations. These are the features of a multiple installa-
tion:
- more systems are supplied by the same sea water electrical pump;
- the compressor of each system must start with a certain delay.
5.8 - CONNECTION TO THE PUMP FOR MULTIPLE INSTALLATIONS
It is available the relay box for the pump as optional. Each air-conditioner is connected to the relay box. The
supply of the pump and of the air-conditioners must not be the same. The first one must be protected by an