CONDIZIONATORI
Modelli COMPACT e SPLIT - QUAT T R O
pag. 19
www.climma.it
5 ELECTRICAL CIRCUIT
AVOID THE RISK OF THE ELECTROCUTION !!!
Only the qualified staff can execute the troubleshooting and the repair.
Keep isolated from the ground during the execution of the electrical operations, wearing dry clothes, rubber
shoes, rubber carpets, etc.... Don’t check wires under voltage if none can bring help.
IMPORTANT NOTE
To avoid possible electrical shocks, that can cause harm or death to people, execute the grounding of the air-
conditioning system, as indicated:
1- Use a suitable electrical cable with ground wire section and isolation to give the charge from the switch on
the control board of the boat to the electrical box of the system. The ground wire must be correctly connect-
ed to the ground terminal of the panel.
2- Check that the ground connection between the electrical box and the air-conditioner hasn’t suffer any da-
mage during the transport.
3- Check that the connection of the water pump to the suitable terminal of the electrical box includes also the
ground connection.
4- Check the ground continuity before switching off the air-conditioner.
WARNING