AIR-CONDITIONERS
COMPACT and SPLIT QUATTRO models
page 16
www.climma.it
4 SEA WATER CIRCUIT
4.1 - SEA WATER ELECTRICAL PUMP
Thanks to the sea water electrical pump the water volume indicated in the exchanger can circulate. The elec-
trical pump must be noiseless. It must work continually and it must be pro-
duced with marine building materials.
4.2 - PLACING
4.2 - A
4.2 - B
4.2 - C
4.2 - D
Install the electrical pump horizontally. Its vertical outlet
opening must be upwards and at least 50 cm below the
water line.
Sea water blade intake towards the bow.
The filter and the connection to the electrical pump must
be linked without any siphon (vertically from the sea water
intake to the electrical pump intake).
The section of the intake pump must be as short as possi-
ble
(less than 1 m for an efficient circuit).
4.3 - FASTENING
Fasten the electrical pump by means of the suitable
screws using the holes provided in the base. The
flexible installation (with anti-vibrating system)
makes the electrical pump even more noiseless.
STERN
BOW
MAX 1 mt