24
CLIMIA
The unit runs but condensate
is not formed:
•
Check the room temperature.
The operating range of the unit
is between 6 °C and 32°C
•
Check the air humidity
min.
40% RH required
•
Check the intake grill and air
filter for contamination
Clean or replace if required!
•
Have the heat exchanger fins
checked for contamination
This work requires the unit to
be opened and must therefore
only be carried out by an
authorised specialist company!
•
Check that the compressor is
functioning correctly. If it is
not operational while the fan
is running, then the leakage
control device has disabled
the compressor. Check the
refrigerant system for leaks.
The unit is loud or condensate
runs out:
•
Check whether the unit is on a
stable and even base
•
Check whether the unit is
standing upright and stably
•
Have the condensate trap or
the connection nozzles checked
to see whether there are dirt
deposits on them
This work requires the unit to
be opened and must therefore
only be carried out by an
authorised specialist company!
NOTE
The units work with
environmentally-friendly and
ozone-neutral R290 refrigerant.
The mixture of refrigerant and oil
within the unit must be disposed
of properly in accordance
with the statutory or locally-
applicable regulations.
NOTE
If the unit fails to function
correctly after the checks have
been carried out, contact an
authorised specialist.
CAUTION!
Work on the refrigerant system
and on the electrical equipment
must only be conducted by a
specially authorised specialist!
Содержание CTK 190
Страница 2: ......
Страница 25: ...25 CTK 190 mobile air dehumidifier ...
Страница 31: ...31 CTK 190 mobile air dehumidifier ...
Страница 32: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...