8.0 Set-up
For the best economic and safe use
of the units, the following notes
must be followed in full:
•
The units must be set up in an
upright and level position, to
ensure that the condensate can
drain freely
•
To ensure optimum air
circulation, the units should be
set up in the centre of the room,
where possible
•
Ensure that the room air can
be sucked in and discharged
without hindrances
•
Observe a minimum clearance of
50 cm from walls at all times
•
Units must never be set up in the
immediate vicinity of heaters or
other sources of heat
•
Air circulation is improved if the
unit is set up approx. 1 m above
the ground
•
The room being dried or
dehumidified must be closed to
the surrounding atmosphere
•
Avoid having opened windows
and doors etc., and avoid
frequent entry to or exit from the
room as much as possible
•
The units may not be used in
environments containing a
great deal of dust or chlorine,
or in places with atmospheres
containing ammonia
•
The output of the unit is
entirely dependent on the
conditions inside the room, room
temperature, relative humidity
and observance of the set-up
instructions
Min. 0.5 m
distance to wall
Maintain adequate clearance from
heaters or other sources of heat.
Keep windows and doors closed!
Fig. 2
Schematic depiction of how to set up the air dehumidifier