20
CLIMIA
Continuous operation with
external condensate outlet
The units are equipped with a
special connection nozzle on the
left side.
A standard 1/2” water hose can
be connected to this.
1. To do this, use a suitable tool to
release the cover [F] from the
unit wall.
Only
required for the first
connection!
2. Connect a sufficiently long
and suitable drain hose to the
connection nozzle that is now
exposed.
In unattended permanent
operating mode, the condensate
should preferably be drained into a
lower-level drain.
If using an external collection
container (pan, bucket, etc.), the
unit must be placed at a correct
height.
F
Emptying the condensate
container
The integrated condensate
container must be emptied from
time to time.
Dehumidification mode is switched
off if the condensate container is
full.
The “Container full” indicator light
indicates that the unit has switched
off.
1. Pull the full container forwards
and out carefully.
2. Pour the water into a drain.
3. Re-insert the emptied container
carefully into the unit.
The “Container full” indicator
light extinguishes and the unit
continues to run automatically.
Leakage control device
The unit is equipped with a
leakage control device to prevent
damage in the event of refrigerant
loss.
If the unit detects a leak, the
compressor is switched off. The
fan continues to operate without
interruption in order to prevent an
accumulation of refrigerant.
NOTE
After being emptied, the
condensate container incl. float
must be checked for damage,
contamination etc.
NOTE
The unit can only be started once
the condensate container has
been inserted correctly.
CAUTION!
There is no unit overflow
protection in this variant.
CAUTION!
Ensure that the drainage hose
is placed at an incline to the
drain to allow the condensate
to drain without hindrance!
CAUTION!
A lack of refrigerant can cause
damage to the unit. If a lack
of refrigerant is detected
(continuous fan operation
when the compressor is
not running), the unit must
be taken out of operation
immediately!
Work on the refrigerant
system and on the electrical
equipment must only be
conducted by a specially
authorised specialist!
The leakage control device
must not be viewed as a
replacement for maintenance
work and damage checks!
NOTE
By switching the compressor
off and on again, the unit
initially continues to run
in normal operation until
the leakage control device
switches the compressor off
again
.