Humidity measuring unit CMG 100

Setting the signal function

   The measuring unit also displays 

three non-numeric measurement 
formats: “DRY” [13] “RISK” [12] and 
“WET” [13] 

   When the humidity status 

reaches “RISK” or “WET”, the 
measuring unit will beep.

   -- In the “RISK” range, the 

measuring unit beeps 
approximately once every 2 
seconds.

   -- In the “WET” range, the 

measuring unit beeps about four 
times per second. 

   By default, a humidity reading 

of <30 will display “DRY”; 30 - 60 
will display “RISK”; and a reading 
above 60 will display “WET”.

   Different materials have different 

moisture tolerance. Please refer 
to the chapter “Technical data” 
in section b) Humidity limit 
ranges for further information. 
Programme your limit range as 
follows:

 
   -- When the “HOLD” symbol [10] is 

displayed, press the SET key [4] to 
enter the signal mode

   -- The “RISK” symbol [12] flashes. 

Press the UP key [7] or the DOWN 
key [3] to adjust the lower limit 
for “RISK”.  
 The value can be set from 0 to 50. 
The factory default setting is 30. 
Press the SET key [4] to confirm 
your selection

   -- The “WET” symbol [13] flashes. 

Press the UP key [7] or DOWN key 
[3] to adjust the lower limit for 

9.0 Care, cleaning 

and maintenance

“WET” The value can be set from 
50 to 100. The factory default 
setting is 60.  
 Press the SET key [4] to confirm 
your selection

   -- The LC display switches back to 

the initial mode (“HOLD”)

   -- The limit value is stored 

permanently until it is next 
changed

Backlight

   If no backlight is switched on, 

press and hold the UP key (7) 
for some time to switch on 
the backlight. The LC display is 
illuminated by white LEDs.] 

   If the backlight is switched on, 

press and hold the UP key (7) 
for a few seconds to switch off 
the backlight. The LC display is no 
longer illuminated

Care and cleaning

   Disconnect the product from 

the power supply before any 
cleaning 

   Never use aggressive cleaning 

agents, cleaning alcohol or other 
chemical solutions, as this may 
attack the housing or even impair 
its function 

   Use a soft, dampened, lint-free 

cloth to clean the product 

   Use only clean water to moisten 

the cloth 

Maintenance

The housing of the humidity 
measuring unit can be opened for 
maintenance by a specialist.

   To open the housing, remove the 

housing screws and the plastic 
knurled nut on the lower shaft 
in an anticlockwise direction. It 
is now possible to separate the 
two halves of the housing. To 
reassemble the housing, carry 
out the process in reverse 

10.0 Scope of delivery

  Humidity measuring unit 

  1 x 9 V block battery 

  Operating manual

Содержание CMG 100

Страница 1: ...CLIMIA Humidity measuring unit CMG 100 Operating manual Edition 1 0 English ...

Страница 2: ......

Страница 3: ...ept in the vicinity of the installation location or on the unit itself Subject to modifications No liability accepted for errors or misprints 1 0 Safety information 4 2 0 Guarantee 5 3 0 Intended use 5 4 0 Environmental protection and recycling 5 5 0 Transportation and packaging 5 6 0 Operation 6 7 0 Commissioning 7 8 0 Use 7 9 9 0 Care cleaning and maintenance 9 10 0 Scope of delivery 9 11 0 Tech...

Страница 4: ...specialist or a specialist workshop If you still have questions that are not answered in this operating manual please contact our technical customer service or other professionals 1 0 Safety information Battery rechargeable battery When inserting the battery rechargeable battery ensure that the polarity is correct Remove the battery rechargeable battery if you are not going to use the unit for a l...

Страница 5: ...e can cause hazards such as short circuits fire etc Read the operating manual carefully and keep it in a safe place Only pass the product on to third parties together with the operating manual The product complies with the legal national and European requirements All company names and product designations contained herein are trademarks of their respective owners All rights reserved 2 0 Guarantee ...

Страница 6: ...6 On Off key 7 UP key 8 Battery compartment on the back 6 0 Operation Fig 2 LC Display 9 10 11 12 13 14 15 18 17 16 Legend 9 Low battery indicator 10 HOLD data storage symbol 11 DRY status symbol 12 RISK status symbol 13 WET status symbol 14 MIN symbol 15 Min humidity level 16 Max humidity level 17 MAX symbol 18 Current humidity level ...

Страница 7: ...ng field of the sensor the measured value increases abruptly due to strong reflections If the spherical head is held in corners e g tile joints or window niches the measured value is generally higher because there is more substance in the scattering field of the measuring head There must be a distance of more than 8 to 10 cm from the corner Hold the measuring unit at its outermost end as far away ...

Страница 8: ... on the display in addition to the last measured value If the HOLD mode is not terminated by pressing the MEAS key 5 the measured values are shown on the LC display for another 30 seconds before the measuring unit switches off automatically Before this time has elapsed press the MEAS key 5 in HOLD mode to exit HOLD mode and perform further measuring procedures After finishing your measurements swi...

Страница 9: ...aintenance WET The value can be set from 50 to 100 The factory default setting is 60 Press the SET key 4 to confirm your selection The LC display switches back to the initial mode HOLD The limit value is stored permanently until it is next changed Backlight If no backlight is switched on press and hold the UP key 7 for some time to switch on the backlight The LC display is illuminated by white LED...

Страница 10: ...on 1 unit Accuracy 1 unit Measuring range 0 100 units Measuring depth mm 20 40 Screw connection tripod mm Inches 6 3 1 4 Operating conditions C r H 0 to 50 C 70 Storage conditions C r H 10 to 60 C 80 relative humidity non condensing Dimensions H x W x D mm 194 x 54 x 34 Weight g 143 without battery We reserve the right to modify the dimensions and design as part of the ongoing technical developmen...

Страница 11: ...ill capable of penetrating thick concrete walls The water required for setting in the production of concrete mortar and plaster etc may only be diffused after 1 2 months Even moisture trapped in the masonry after high water or a flood is released very slowly The same is also true of moisture contained in stored materials for example The moisture water vapour released from parts of a building or ma...

Страница 12: ... content becomes greater as the temperature rises Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m The drying of moist materials such as masonry is effected as follows The moisture moves from the inside of the material to its surface Evaporation occurs on the surface Transfer of wa...

Страница 13: ...sation heat The energy transferred to the air from the condenser consists of 1 The amount of heat derived beforehand in the evaporator 2 The electrical drive energy 3 The condensation heat released by liquefying the water vapour Energy must be supplied when liquid is converted into a gas This energy is designated as evaporation heat It does not cause any increase in temperature but is required to ...

Страница 14: ...14 CLIMIA Notes ...

Страница 15: ...15 Humidity measuring unit CMG 100 ...

Страница 16: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...

Отзывы: