Humidity measuring unit CMG 100

The diagram opposite illustrates 
the corrosion rate, e.g. for metal, 
at different humidity levels. It can 
be seen that the corrosion rate is 
insignificant below 50 % relative 
humidity (RH) and negligible below 
40 % RH. 
 
The corrosion rate increases 
significantly above 60% RH. This 
threshold for damage as the 
result of humidity also applies to 
other materials, such as powdery 
substances, packaging, wood and 
electronic units.

Buildings may be dried in a variety 
of ways:

The correlations occurring when 
air is dehumidified are based on 
physical laws.  
These are depicted here in graphical 
form in order to provide you with a 
brief overview of the principles of 
air dehumidification.

Using 

Climia air dehumidifiers

   Even if windows and doors 

are well insulated, water and 
moisture are still capable of 
penetrating thick concrete walls.

   The water required for setting 

in the production of concrete, 
mortar and plaster etc. may only 
be diffused after 1-2 months.

   Even moisture trapped in the 

masonry after high-water or a 
flood is released very slowly.

   The same is also true of moisture 

contained in stored materials for 
example.

The moisture (water vapour) 
released from parts of a building 
or materials is absorbed by the 
surrounding air. As a result, the 
moisture content increases, which 
ultimately gives rise to corrosion, 
mould, rot, peeling of paint and 
other unwanted damage.

12.0 Air dehumidification

Corrosion rate

Rel. humidity %

1.  

By heating and 

air exchange:

   The air in the room is heated 

in order for moisture to be 
removed and then this air is fed 
outside. All of the energy that 
is involved is lost together with 
the moist air that is released.

2.  

By air dehumidification:

   The moist air that is present 

within an enclosed space is 
continuously dehumidified 
according to the condensation 
principle.

Содержание CMG 100

Страница 1: ...CLIMIA Humidity measuring unit CMG 100 Operating manual Edition 1 0 English ...

Страница 2: ......

Страница 3: ...ept in the vicinity of the installation location or on the unit itself Subject to modifications No liability accepted for errors or misprints 1 0 Safety information 4 2 0 Guarantee 5 3 0 Intended use 5 4 0 Environmental protection and recycling 5 5 0 Transportation and packaging 5 6 0 Operation 6 7 0 Commissioning 7 8 0 Use 7 9 9 0 Care cleaning and maintenance 9 10 0 Scope of delivery 9 11 0 Tech...

Страница 4: ...specialist or a specialist workshop If you still have questions that are not answered in this operating manual please contact our technical customer service or other professionals 1 0 Safety information Battery rechargeable battery When inserting the battery rechargeable battery ensure that the polarity is correct Remove the battery rechargeable battery if you are not going to use the unit for a l...

Страница 5: ...e can cause hazards such as short circuits fire etc Read the operating manual carefully and keep it in a safe place Only pass the product on to third parties together with the operating manual The product complies with the legal national and European requirements All company names and product designations contained herein are trademarks of their respective owners All rights reserved 2 0 Guarantee ...

Страница 6: ...6 On Off key 7 UP key 8 Battery compartment on the back 6 0 Operation Fig 2 LC Display 9 10 11 12 13 14 15 18 17 16 Legend 9 Low battery indicator 10 HOLD data storage symbol 11 DRY status symbol 12 RISK status symbol 13 WET status symbol 14 MIN symbol 15 Min humidity level 16 Max humidity level 17 MAX symbol 18 Current humidity level ...

Страница 7: ...ng field of the sensor the measured value increases abruptly due to strong reflections If the spherical head is held in corners e g tile joints or window niches the measured value is generally higher because there is more substance in the scattering field of the measuring head There must be a distance of more than 8 to 10 cm from the corner Hold the measuring unit at its outermost end as far away ...

Страница 8: ... on the display in addition to the last measured value If the HOLD mode is not terminated by pressing the MEAS key 5 the measured values are shown on the LC display for another 30 seconds before the measuring unit switches off automatically Before this time has elapsed press the MEAS key 5 in HOLD mode to exit HOLD mode and perform further measuring procedures After finishing your measurements swi...

Страница 9: ...aintenance WET The value can be set from 50 to 100 The factory default setting is 60 Press the SET key 4 to confirm your selection The LC display switches back to the initial mode HOLD The limit value is stored permanently until it is next changed Backlight If no backlight is switched on press and hold the UP key 7 for some time to switch on the backlight The LC display is illuminated by white LED...

Страница 10: ...on 1 unit Accuracy 1 unit Measuring range 0 100 units Measuring depth mm 20 40 Screw connection tripod mm Inches 6 3 1 4 Operating conditions C r H 0 to 50 C 70 Storage conditions C r H 10 to 60 C 80 relative humidity non condensing Dimensions H x W x D mm 194 x 54 x 34 Weight g 143 without battery We reserve the right to modify the dimensions and design as part of the ongoing technical developmen...

Страница 11: ...ill capable of penetrating thick concrete walls The water required for setting in the production of concrete mortar and plaster etc may only be diffused after 1 2 months Even moisture trapped in the masonry after high water or a flood is released very slowly The same is also true of moisture contained in stored materials for example The moisture water vapour released from parts of a building or ma...

Страница 12: ... content becomes greater as the temperature rises Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m The drying of moist materials such as masonry is effected as follows The moisture moves from the inside of the material to its surface Evaporation occurs on the surface Transfer of wa...

Страница 13: ...sation heat The energy transferred to the air from the condenser consists of 1 The amount of heat derived beforehand in the evaporator 2 The electrical drive energy 3 The condensation heat released by liquefying the water vapour Energy must be supplied when liquid is converted into a gas This energy is designated as evaporation heat It does not cause any increase in temperature but is required to ...

Страница 14: ...14 CLIMIA Notes ...

Страница 15: ...15 Humidity measuring unit CMG 100 ...

Страница 16: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...

Отзывы: