General safety notes

Carefully read the operating manual 
before placing the unit in service 
for the first time. It contains useful 
tips and notes as well as hazard 
warnings to prevent injury or 
material damage. Failure to follow 
the directions in this Manual can 
endanger persons, the environment 
and the equipment itself and will 
void any claims for liability.

 

The product is not a toy. Keep it 
away from children and pets.

 

Do not leave the packaging 
material carelessly lying around. 
This could become hazardous to 
children.

 

Protect the product from extreme 
temperatures, direct sunlight, 
strong vibrations, excessive 
humidity, moisture, flammable 
gases, vapours and solvents. 

 

Do not expose the product to 
mechanical stress.

 

If safe use is no longer possible, 
take the product out of service 
and secure it against accidental 
use. Safe use is no longer 
guaranteed if the product: 
- exhibits visible damage, 
- no longer functions properly, 
- has been stored for a 
longer period of time under 
unfavourable environmental 
conditions or 
- has been subjected to 
considerable transport stresses.

 

Handle the product with care. It is 
damaged by bumps, impacts or 
falling from even a low height.

 

Consult a professional if you have 
any doubts about the operation, 
safety or connection of the 
product.

 

Have maintenance, adaptation 
and repair work carried out 
exclusively by a specialist or a 
specialist workshop.

 

If you still have questions that are 
not answered in this operating 
manual, please contact our 
technical customer service or 
other professionals.

1.0 Safety information

Battery/rechargeable battery

 

When inserting the battery / 
rechargeable battery, ensure 
that the polarity is correct.

 

Remove the battery / 
rechargeable battery if you are 
not going to use the unit for a 
long time to avoid damage due 
to discharge. Discharging or 
damaged rechargeable batteries 
can cause acid burns if they 
come into contact with the 
skin. You should therefore wear 
protective gloves when handling 
damaged batteries/rechargeable 
batteries.

 

Keep rechargeable batteries out 
of the reach of children. Do not 
leave rechargeable batteries 
lying around as they could be 
swallowed by children or pets.

 

Do not disassemble, short circuit 
or dispose of rechargeable 
batteries in fire. Never attempt 
to charge non-rechargeable 
batteries. There is a risk of 
explosion!

The following notes must be 

observed in full:

People and product

 

If the unit is brought from a 
cold to a warm environment, 
condensate water may form 
inside the unit. This can lead to 
incorrect measurement results. 
Before using the unit, let it rest 
for a while until it has adapted to 
the new ambient air.

 

The user is responsible for 
the measurement results 
of this unit. We do not 
guarantee the accuracy of 
the measurement results, nor 
do we accept responsibility for 
them. Under no circumstances 
do we accept responsibility 
for damage caused by the 
application of the measurement 
results.

Содержание CMG 100

Страница 1: ...CLIMIA Humidity measuring unit CMG 100 Operating manual Edition 1 0 English ...

Страница 2: ......

Страница 3: ...ept in the vicinity of the installation location or on the unit itself Subject to modifications No liability accepted for errors or misprints 1 0 Safety information 4 2 0 Guarantee 5 3 0 Intended use 5 4 0 Environmental protection and recycling 5 5 0 Transportation and packaging 5 6 0 Operation 6 7 0 Commissioning 7 8 0 Use 7 9 9 0 Care cleaning and maintenance 9 10 0 Scope of delivery 9 11 0 Tech...

Страница 4: ...specialist or a specialist workshop If you still have questions that are not answered in this operating manual please contact our technical customer service or other professionals 1 0 Safety information Battery rechargeable battery When inserting the battery rechargeable battery ensure that the polarity is correct Remove the battery rechargeable battery if you are not going to use the unit for a l...

Страница 5: ...e can cause hazards such as short circuits fire etc Read the operating manual carefully and keep it in a safe place Only pass the product on to third parties together with the operating manual The product complies with the legal national and European requirements All company names and product designations contained herein are trademarks of their respective owners All rights reserved 2 0 Guarantee ...

Страница 6: ...6 On Off key 7 UP key 8 Battery compartment on the back 6 0 Operation Fig 2 LC Display 9 10 11 12 13 14 15 18 17 16 Legend 9 Low battery indicator 10 HOLD data storage symbol 11 DRY status symbol 12 RISK status symbol 13 WET status symbol 14 MIN symbol 15 Min humidity level 16 Max humidity level 17 MAX symbol 18 Current humidity level ...

Страница 7: ...ng field of the sensor the measured value increases abruptly due to strong reflections If the spherical head is held in corners e g tile joints or window niches the measured value is generally higher because there is more substance in the scattering field of the measuring head There must be a distance of more than 8 to 10 cm from the corner Hold the measuring unit at its outermost end as far away ...

Страница 8: ... on the display in addition to the last measured value If the HOLD mode is not terminated by pressing the MEAS key 5 the measured values are shown on the LC display for another 30 seconds before the measuring unit switches off automatically Before this time has elapsed press the MEAS key 5 in HOLD mode to exit HOLD mode and perform further measuring procedures After finishing your measurements swi...

Страница 9: ...aintenance WET The value can be set from 50 to 100 The factory default setting is 60 Press the SET key 4 to confirm your selection The LC display switches back to the initial mode HOLD The limit value is stored permanently until it is next changed Backlight If no backlight is switched on press and hold the UP key 7 for some time to switch on the backlight The LC display is illuminated by white LED...

Страница 10: ...on 1 unit Accuracy 1 unit Measuring range 0 100 units Measuring depth mm 20 40 Screw connection tripod mm Inches 6 3 1 4 Operating conditions C r H 0 to 50 C 70 Storage conditions C r H 10 to 60 C 80 relative humidity non condensing Dimensions H x W x D mm 194 x 54 x 34 Weight g 143 without battery We reserve the right to modify the dimensions and design as part of the ongoing technical developmen...

Страница 11: ...ill capable of penetrating thick concrete walls The water required for setting in the production of concrete mortar and plaster etc may only be diffused after 1 2 months Even moisture trapped in the masonry after high water or a flood is released very slowly The same is also true of moisture contained in stored materials for example The moisture water vapour released from parts of a building or ma...

Страница 12: ... content becomes greater as the temperature rises Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m The drying of moist materials such as masonry is effected as follows The moisture moves from the inside of the material to its surface Evaporation occurs on the surface Transfer of wa...

Страница 13: ...sation heat The energy transferred to the air from the condenser consists of 1 The amount of heat derived beforehand in the evaporator 2 The electrical drive energy 3 The condensation heat released by liquefying the water vapour Energy must be supplied when liquid is converted into a gas This energy is designated as evaporation heat It does not cause any increase in temperature but is required to ...

Страница 14: ...14 CLIMIA Notes ...

Страница 15: ...15 Humidity measuring unit CMG 100 ...

Страница 16: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...

Отзывы: