![ClimExel DH-120 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/climexel/dh-120/dh-120_installation-and-operating-instructions-manual_2625149006.webp)
20/28
2015/12 - Indice de révision : B - Code : 33491
The machine is fitted with HP and LP safety mechanisms controlled by a pressure switch.
The LP pressure switch stops the compressor if the pressure drops below 0.05 MPa and automatically
resets when the pressure rises above 0.15 MPa.
OFF : 0.05 MPa
ON : 0.15 MPa
The HP pressure switch stops the compressor when the pressure rises above 4.2 MPa, and automatically
resets when the pressure drops below 3.6 MPa.
OFF : 4.2 MPa
ON : 3.6 MPa
The machine is fitted with a n air circulation defrosting function.
Installation
Take into account the minimum distance limitations between the dehumidifier and the water body,
specified in the regulations in effect, when selecting the installation site.
If the machine is free-standing, it must be set on solid, stable and horizontal surface.
The dehumidifier is delivered with 4 height adjustable, vibration damping pads to be
screwed into place beneath the machine.
A flexible, translucent condensate drainage tube (length 2 m) is
also supplied. This should be connected to the machine under the
power cable connection.
The dehumidifier may also be mounted on
a wall using the two slots located on the
rear panel. Before mounting the device on
a wall, verify that the wall, and the means
of anchoring it to the wall, will support the
weight of the machine.
The remote installed control pad is fitted with a 10 m cable attached by a
quick disconnect fitting. The control pad is not watertight so it should be
protected from the elements
.
Control pad cable
Power cable
Condensate drainage tube (to be
installed)