21
You can select the length of the interval between auto check-in reports.
There will be no auto check-
in report if you select “Disable.”
Whenever VCP-LTE is programmed, the auto check-in timer will be reset.
Auto Check-In Offset:
After VCP-LTE is rebooted, reset or programmed, the system will start
counting down the time for the first Auto check-in report.
VCP-LTE will send the first check-in report according to the setting of Auto
Check-In Offset time. Afterwards, VCP-LTE will send reports according to the
setting of Auto Check-in Interval
Supervision Timer:
The VCP-LTE monitors accessory devices according to the supervision signal
transmitted regularly from the device. Use this option to select a time period
for receiving supervision signals. If the VCP-LTE fails to receive supervision
signal from a device within this duration, it will consider the device out of order
and report the event accordingly.
Supervision Timer Repeated:
Set the interval that the supervision failure report will be repeated after the
first Supervisory Failure event is reported.
Guard Time Sound:
S
elect “on” to enable beeps during guard time or “off” to disable the beeping
sound during guard time.
Confirmation Sound:
Select “on” to enable confirmation beeps during reporting or “off” to disable
confirmation beeps during reporting.
Mobile Silent
When this function is set to
“On”, silent mode is turned on where all sounds
are silent.
When this function is set to
“Off”, silent mode is turned off.
When Mobile Silent is enabled, a Listen-in only communication will be
established initially for Speech Reporting. The call recipient can enter DTMF
keys to change communication types (please refer to
5.2. Alarm Activation
for more details).
Two way volume level
Adjust the speaker volume of VCP-LTE from a scale of 1-5, where
1 = minimum speaker volume
5 = maximum speaker volume
Microphone Sensitivity Level