background image

 

16 

Zone Wiring (Zone 1 -16) 

 

 

The  16  zones  can  be  wired  to  supervise  NC  (normally  close)  or  NO  (normally  open) 
devices. Connect hardwired devices into any Zone terminal. 

 

Wire gauge: Minimum 20 AWG, maximum 18 AWG. Do not use shielded wire. 

 

The  hardwired  zones  support  Single-End-of-Line  (SEOL)  or  Double-End-of-Line  (DEOL) 
loop configuration, with a value from 1K, 2.2K, 3.74K, 4.7K, 5.6K, 6.8K, 8.2K, 10K ohms. 
Please install the resistor(s) at the end of each zone loop far away from the Control Panel. 
The Panel will detect if the circuit is secure, open, or short. 

 

For an NC loop, please have an EOL resistor in series with the loop.   

 

For an NO loop, please have an EOL resister in parallel (across) the loop. Please refer to 
the following diagrams for wiring examples. 

 

There is no EOL resistor in loop 1 and loop 2. 

 

NO/NC Wiring 

1. 

2. 

 

 

 
Single-End-of-Line Resistor Wiring 

3. 

4. 

 

 

Содержание Hybrid-Panel Series

Страница 1: ...Hybrid Security Alarm System User Manual Dec 16 2020...

Страница 2: ...__________________________________________________________________ 39 5 5 EXCLUSION ______________________________________________________________________ 40 5 6 SHUTTER CONTROL TOOL _________________...

Страница 3: ...______________________________________________ 90 8 15 IO MCU FIRMWARE UPGRADE _______________________________________________________ 91 8 16 FACTORY RESET ___________________________________________...

Страница 4: ...s built in RF Z Wave and or ZigBee modules The Hybrid Panel Series include the following models Name Reporting Path Modules Hybrid Panel 1 LA IP GPRS Reporting IP Gateway supporting Sealed Lead Acid S...

Страница 5: ...esistors are included in shipment Ethernet interface RJ 45 connection Electrical External AC DC adaptor 12VDC 2A Power supply2 1 16 18VAC 40VA 50 60Hz 2 100 230VAC 50 60Hz 3 12VDC 2A Total current con...

Страница 6: ...MHz B3 1800 MHz B5 850 MHz B7 2600 MHz B8 900 MHz B20 800 MHz US B2 1900 MHz B4 1700 MHz B12 700 MHz 3G Frequency EU B1 2100 MHz B5 850 MHz B8 900 MHz US B2 1900 MHz B4 1700 MHz B5 850 MHz RF Frequenc...

Страница 7: ...4 2 Panel Information 2 1 Identifying the parts Top Cover front view Top View...

Страница 8: ...5 Top Cover internal view...

Страница 9: ...6 Back Cover internal view...

Страница 10: ...H rechargeable battery pack depending on capacity purchased 7 U shaped Grommet x 4 To be used to replace the Removable Protective Cover to enhance wiring and cord management flexibility Ensure to save...

Страница 11: ...Connect to 12VDC 2A power supply Don t use Built in Power Unit and DC Jack together 27 Zone Terminal 12V Auxiliary Voltage Output Terminal GND Terminal Zone 1 16 Hardwired Input Zones supporting up to...

Страница 12: ...to Using the built in Power Unit in 3 3 Hardware Installation for more details Please note Don t use the adaptor and the Built in Power Unit at the same time Ensure to turn off all power supplies incl...

Страница 13: ...d devices A central location between all the devices is often the best place making wiring to expanders or devices easier and preferably a place that is hidden from outside view Avoid mounting the Con...

Страница 14: ...ep 2 Use the 4 mounting holes as a template to mark and drill holes appropriately Step 3 Use the provided wall plugs for plaster brick installation Make sure the wall plugs are flush with the wall Ste...

Страница 15: ...term attachment For Hybrid Panel 1 NH Hybrid Panel 1B NH ensure the battery connector plug is on the top LEFT HAND side of the battery pack when the Velcro tape s is applied for battery connection fl...

Страница 16: ...3 Hardware Installation Step 8 Arrange all wires along the wire clips and then route the wires to the two cable holes on top Use cable ties not included to thread through the wire clips and secure the...

Страница 17: ...14 Step 9 Close the cover and tighten the cover fixing screw...

Страница 18: ...fter the SIM card is re inserted To reset GSM please refer to 7 1 GSM Step 3 Complete wiring for Zone 1 16 terminals GND terminals AUX power terminals PGM terminals Bell terminals Keypad terminals and...

Страница 19: ...ation with a value from 1K 2 2K 3 74K 4 7K 5 6K 6 8K 8 2K 10K ohms Please install the resistor s at the end of each zone loop far away from the Control Panel The Panel will detect if the circuit is se...

Страница 20: ...Panel can provide a maximum of 12V 400mA current for hardwired zones auxiliary output and KP 35 COMBO Min Max operating voltages for devices detectors is 11 4VDC 13VDC Please note that the total curre...

Страница 21: ...as a dry contact relay output When the J24 jumper link is inserted connecting the 1st and 2nd pins the PGM port will provide 12V output When the J24 jumper link is inserted connecting the 2nd and 3rd...

Страница 22: ...erve polarity when connecting polarized sirens or bells Keypad Wiring The Keypad terminals can connect to a maximum of 4 wired keypads KP 35 COMBO Connect the Control Panel s GND to the G terminal on...

Страница 23: ...correctly as it is within 500 152m of the panel in wire distance Since it has the furthest distance from the Control Panel ensure its jumper switch is set to ON to serve as a terminating resistor bef...

Страница 24: ...ttery pack 4 7 2V 2300mAh NiMH battery pack NOTE When there is a need of two SLA batteries make sure to use two batteries with the same battery capacity in Ah For example both batteries must be 12V 7A...

Страница 25: ...Open Frame connect BROWN wire of the power cord to Terminal L of the built in Power Unit and connect BLUE wire to Terminal N Please refer to two figures below Note DO NOT use Built in Power Unit and...

Страница 26: ...23 Open Frame built in Power Unit...

Страница 27: ...til all wiring is complete The control panel enclosure must be secured to the wall before operation Internal wiring must be routed in a manner that prevents Wiring over circuit boards Excessive strain...

Страница 28: ...tp www climax com tw climax download finder html Step 2 After download install the software and follow on screen instructions to complete installation Step 3 Follow on screen instruction to complete i...

Страница 29: ...not displayed check panel power and Ethernet connection and click on Search to update the panel information Step 7 Optional You can choose to edit the panel s network setting by clicking on the panel...

Страница 30: ...g enter the user name default admin and password default cX HsA 7F1 then click OK to confirm The user name and password can be changed later in panel configuration webpage Step 8 Click the panel infor...

Страница 31: ...the Control Panel IP address displayed in Finder into your browser s address section and proceed Step 2 Enter the User name Password to proceed User name admin Password cX HsA 7F1 If wrong user name a...

Страница 32: ...f you wish to include more than 40 ZigBee devices into the Control Panel you must add extra ZigBee Routers into the Control Panel s ZigBee network to increase the network s maximum device capacity IP...

Страница 33: ...section NOTE For VST 862 F1 devices press and hold the learn button for 3 seconds for the Control Panel to receive a learn code and then click Add within 30 seconds Step 6 If the device is successful...

Страница 34: ...l Panel will emit 2 short beeps to indicate it has returned to normal operation mode LED 1 2 will dim If the user does not press the button within 5 6 minutes the system will automatically return to n...

Страница 35: ...evice belongs to Zone Select the Device zone number Attribute List The attribute list determines panel behaviour when the panel receives trigger signal from the device There are General Attribute Perm...

Страница 36: ...not respond Start Entry Delay 1 Start Entry Delay 2 When the system is under Full Arm or Home Arm mode if a sensor with Start Entry Delay 1 2 attribute is triggered Control Panel will start an entry c...

Страница 37: ...for Remote Keypad and Remote Control Select a Home Automation Scene number for a Remote Keypad or Remote Control button When the button is pressed the Control Panel will execute the actions programmi...

Страница 38: ...ZigBee devices after learning For battery powered ZigBee devices the identify fuction should be used within 1 minute after pressing device button or 3 minute after learning in the device Otherwise due...

Страница 39: ...ce Step 2 Select Area and Zone number for the device you wish to add into system Step 3 Enter the device RF code and preferred device name up to 31 characters Step 4 Press OK to save Step 5 If the RF...

Страница 40: ...rn Rule Step 2 You will see the Add Learn Rule menu Step 3 Select Area and Zone number for this device Step 4 Select RF or ZigBee Step 5 Key in the RF code or ZigBee MAC info Step 6 For ZigBee device...

Страница 41: ...eed to follow the instruction in 5 1 1 Add Sensor to complete the learning process Backup Device List to Learn Rule You can choose to import learn rule from current learnt in ZigBee devices Step 1 Cli...

Страница 42: ...Time time informaiton Area operation area Zone device zone Type device type Name device name RSSI the RF signal strength between Control Panel and sensor The RSSI value here must be higher than the R...

Страница 43: ...trol device only Step 1 Click on Exclusion and click on Start to start the procedure Then the Panel will enter the removing mode Step 2 Refer to the Shutter Control device manual to transmit signal St...

Страница 44: ...o factory default and all Shutter Control devices will be removed automatically The Control Panel Home ID will also be changed automatically for a newly added Shutter Control device to recognize Step...

Страница 45: ...nel Click Edit to edit attributes of power switches Click Delete to remove power switch from panel Click Switch On Switch Off to turn on off power switches Or click Switch Toggle to toggle between on...

Страница 46: ...f the 5 surrounding LEDs can be selected to activate upon IR signal transmission to increase the IR signal coverage Step 1 Refer to the diagram on the webpage and UPIC5 manual to determine which LED s...

Страница 47: ...ength setting Please refer to IP Camera manual for detail For PIR Camera Video Camera you can choose to take the picture video without activating the camera s flash Picture and video captured by PIR C...

Страница 48: ...to turn on or off one group of power switches 5 10 2 Device Edit Delete Step 1 Check on the groups you wish to assign the Power Switch This is a multiple choice field and you can assign one Power Swi...

Страница 49: ...etting page includes setting Siren configuration function 5 11 1 Device Edit Delete Click Edit to edit the Siren s attribute volume and voice settings or Delete to delete the Siren After clicking Edit...

Страница 50: ...o Zone Select the Siren zone number Attribute Permanently Bypass If checked the Control Panel will completely ignore all signal received from the Siren A bypassed Siren will not be able to trigger any...

Страница 51: ...lume of the voice played when system is force armed under fault conditions Pre alarm outdoor IR warning beeps set the volume of the voice played when an outdoor burglar sensor Door Contact IR is trigg...

Страница 52: ...e disable all RF Sirens tamper protection with this function Select to turn on or off the sirens tamper function NOTE When turned off if siren tamper will be enabled again automatically after one hour...

Страница 53: ...he wired sensor zone wiring and the EOL resistance for each zone Type Select the type of the wired sensor for each zone from the drop down menu Loop Select the number to correspond to the zone wiring...

Страница 54: ...k OK to save changes when finished Alternatively click Reset to re enter all the information Step 4 If the process is successful the screen will display Updated Successfully The sensor will be assigne...

Страница 55: ...tion allows user to permanently deactivate bypass the selected device If bypassed then the Control Panel will not respond at all when the sensor is triggered If bypassed the system can be armed direct...

Страница 56: ...the Control Panel is in the Full Arm mode if a sensor with Start Entry Delay 1 2 attribute is triggered the Entry Delay 1 2 timer starts counting down If no correct pin code is entered during the entr...

Страница 57: ...l Restore Response When the device transmits restore signal after trigger the Control Panel will activate selected Home Automation Scene number Other Attributes Permanent Bypass When checked the panel...

Страница 58: ...The Control Panel will update the panel status periodically However in order to show the current status you must reload the screen to refresh the display Battery When battery is running low a low batt...

Страница 59: ...information on the webpage If you still want to arm the system perform the arming action again to force arm You can check the Clear box in the setting column then click OK to ignore the fault event C...

Страница 60: ...values will be kept without any change Note The function is designed for installer to make a note for each control panel The note you make here can be delivered to a server over XMPP or polling protoc...

Страница 61: ...port to the Central Monitoring Station according to the duration set under AC Fail Report If 5 minutes is set the event will be automatically reported to the CMS after 5 minutes Your Control Panel wil...

Страница 62: ...select the resolution and number of pictures taken by PIR Camera when the camera detects a movement in armed mode Options available are 320x240x3 images Default 320x240x6 images and 640x320x3 images...

Страница 63: ...er changes system mode to Full Arm the panel will begin Exit Delay Timer Countdown and enter Full Arm mode when the timer expires The user must leave area protected by sensors before the timer expires...

Страница 64: ...me Arm this is for you to decide whether the Control Panel sounds count down beeps and volume of beep during the exit delay timer in the home arm mode Confirm Sound this is for you to decide whether t...

Страница 65: ...t the area for setting User PIN Code User Code Setting User Code Enter the 4 digit code in the field User Name Enter a user name for easy recognition of system events Up to 17 alphanumerical character...

Страница 66: ...ntend to use the GSM funciton please tick NO to ensure the system will not check if the SIM card is inserted or not and it will not display the GSM fault by LED flashing GPRS In order to allow GPRS to...

Страница 67: ...your telecom service provider Password Enter the password for accessing the MMS feature provided by your telecom service provider URL Enter the MMS APN URL provided by your telecom service provider P...

Страница 68: ...on this web configuration page Step 1 Click Send SMS Step 2 Enter a desired phone number and text message Reset GSM This feature is designed for you to reset GSM module Step 1 Click GSM Reset Step 2...

Страница 69: ...also enter the Network information manually for IP Address Subnet Mask Default Gateway Default DNS 1 and Default DNS 2 Please make sure that you have obtained all required values according to your Net...

Страница 70: ...network 1 Search for WiFi AP Click Scan WiFi AP to search for available wireless network Select the available Wireless APs from the list by clicking Set after AP info column and enter the required in...

Страница 71: ...t Redirect The device will try to find an UPnP supported router and set up the port to redirect to the router Port Forwarding Port forwarding function allows you to configure specific communication po...

Страница 72: ...new Administrator Log in Name and Password Please note both User Name and Password are case sensitive Step 1 Enter the preferred User Name Step 2 Enter the preferred Password in the New Password field...

Страница 73: ...termines under which circumstances the rule should be activated Empty When set as Empty the system will follow the schedule time and execution rule to respond accordingly Trigger Alarm When set as Tri...

Страница 74: ...r exceeds set threshold the rule will be activated according to rule schedule and execution setting Temperature Between When set as Temperature Between if the temperature detected by specified tempera...

Страница 75: ...me Once When set as Once the system will follow the rule condition and execute rule according to the exact date and time specifed Every Month When set as Every Month the system will follow the rule co...

Страница 76: ...Switch On Turn on all Power Switches assigned to specified group Group Switch On For Turn on all Power Switches assigned to specified group for a set duration Group Switch Level Change the power outpu...

Страница 77: ...d IP Cameras in the system will record a video Setup UPIC The UPIC and specified zone will transmit Off Heat Cool command to the air conditioner as programmed Hue Control Adjust the hue and saturation...

Страница 78: ...2 Home Automation For example you can set a scene to control multiple lightings then set your Remote Controller to activate the scene when the button is pressed or set a Home Automation Rule to activ...

Страница 79: ...76 included in one scene Step 6 Click Done Step 7 Click OK at bottom of webpage to confirm the new scene setting...

Страница 80: ...ber server ip port SIA Example ip 1234 54 183 182 247 8080 SIA 3 SIA DC 09 protocol via IP with AES encryption Format ip Account Number server ip port SIA KEY 128 196 or 256 bits Key Example ip 1234 5...

Страница 81: ...ll consider reporting to this group successful and stop reporting to rest of the destinations in the group It will then move on to report to the next group If reporting to all destinations in a group...

Страница 82: ...RL1 will be filled in with Home Portal Server report information Do not change the information once registration is complete or reporting to Home Portal Server may encounter error After registering th...

Страница 83: ...Off for Temporary Code by tick the Latch Option box and press OK to confirm the settings Installer Code The Installer Code is used for SMS Remote Programming when sending a remote programming message...

Страница 84: ...orary Code is ONLY valid for one access per arming and disarming Afterwards the Temporary Code will be automatically erased and needs to be reset for a new Temporary user The Temporary Code consists o...

Страница 85: ...bets User set the mail account name max 30 digits alphabets Password set the password corresponding to the mail account name max 30 digits alphabets From set the email address according to your mail s...

Страница 86: ...r transmitting an alarm image over Ethernet Manitou manitou user server port MMS via Telephone mms telephone number MMS via GPRS mms user mail server transmitting an alarm image over MMS NOTE If Delet...

Страница 87: ...ling The polling function enables the Control Panel to query the destiation you set URL1 or URL2 in turn as to whether it has any data to transmit URL URL2 ip server port path Interval interval time o...

Страница 88: ...nected from the server it will retry connection every 3 minutes Server server address dependent upon default firmware US server us vestasmarthome com EU server eu vestasmarthome com Taiwan server tw v...

Страница 89: ...and time Time Zone choose your time zone and then the system will calculate the daylight saving time automatically if necessary Internet Time the system will automatically synchronize with an internet...

Страница 90: ...87 8 11 Dynamic DNS This page is used to provide you the Control Panel s current public IP address Dynamic DNS Server http checkip dyndns org...

Страница 91: ...is for you to test the Control Panel internet connection Step 1 Enter the URL destination you want to test connection to Step 2 Enter the test interval Step 3 Click OK You can check the test connect...

Страница 92: ...lick on Choose File and locate the latest firmware file in your PC Step 2 Press Apply to upload the latest firmware to Control Panel Step 3 Wait for 1 min and do NOT power off during this time Step 4...

Страница 93: ...ick on Choose File and locate the latest firmware file unzipped image bin file in your PC Step 2 Press Apply to upload the latest firmware to Control Panel Step 3 Wait for 1 min and do NOT power off d...

Страница 94: ...Step 2 Click on Choose File and locate the latest firmware file in your PC Step 3 Press Apply to upload the latest firmware to Control Panel Step 4 Wait for 1 min and DO NOT power off during this time...

Страница 95: ...ult Tick the Kept current device list box to keep the current learnt in devices Otherwise the system will reset its value back to factory default Step 2 Press Yes to continue the Reset procedure Step...

Страница 96: ...esides you also can restore pre programmed settings 8 17 1 Backup Data Click Download and you can back up all programmed data and save these programmed values into a file 8 17 2 Restore Settings Step...

Страница 97: ...94 8 18 System Log The sytem log webpage logs the control panel s detail system operation history System Log File Download Click to download a detail log files into your computer for more information...

Страница 98: ...it will take a 10 second video clip You can also request the PIR Camera to take a picture and PIR Video Camera to take a 10 second video clip manually Caputred events will be displayed in this page w...

Страница 99: ...iggered events by the control panel by recording the events CID event code and report status Reload Click to refresh the page content Limit of Items Click the drop down menu on the pageto select the n...

Страница 100: ...ge records specific actions performed by the Control Panel and accessory devices Reload Click to refresh the page content Limit of Items Click the drop down menu on the pageto select the numbers of ca...

Страница 101: ...emperature Sensor the update history power consumption or temperature ireading will be displayed under this page the current info is also displayed under Panel and PSS Control Reload Click to refresh...

Страница 102: ...event is generated Panel Tamper The tamper switch on back of the panel is not compressed against the back cover This means the panel s cover is opened and not properly sealed Battery Dead Missing The...

Страница 103: ...Alarm No Response Door Chime Burglar Follow Instant Burglar Alarm Instant Burglar Alarm Instant Burglar Alarm Instant Burglar Alarm No Response Delayed Burglar Alarm Burglar Instant Instant Burglar Al...

Страница 104: ...nstant Silent Panic Alarm 24H Panic Instant Panic Alarm Instant Panic Alarm Instant Panic Alarm Instant Panic Alarm Instant Panic Alarm Instant Panic Alarm 24H Emergency Instant Emergency Alarm Instan...

Страница 105: ...anel begins to sound alarm counts down Cross Zone Timer and reports a Cross Zone First Trip event CID 693 If the Cross Zone Timer expires without any other sensor trigger the panel reports Cross Zone...

Страница 106: ...is triggered the panel begins to sound alarm counts down Fire Verification Timer and reports a Near Alarm event CID 118 Triggering any Smoke Detector with Fire Verification attribute including the or...

Страница 107: ...vent code 3 Hex digits 0 9 B F GG Group Partition number 00H or Area Number 00 panel 01 area 1 xx area xx C1C2C3 1 For devices zone C1C2C3 Zone number 001 Zone 1 002 Zone 2 XXX Zone XXX 2 For Panel co...

Страница 108: ...device set as Burglar Instant is triggered under Disarm Full Arm or Home Arm mode 131 Burglar Perimeter When a device set as Entry is triggered in Full Arm mode When a device set as Burglar Follow is...

Страница 109: ...Panel is low When the panel battery restores voltage 311 Battery Disconnection Battery Reconnected 344 Interference Interference problem solved 358 Network Cable Unplugged When the Ethernet cable is...

Страница 110: ...ay time is reached When arm fault type is set as Direct Arm Door Contact is not closed after the preset exit delay time is reached 602 Periodic test report When the control panel makes periodic Check...

Отзывы: