Time Setting
Supervision Timer
: The Control Panel monitors accessory devices according to the
supervision signal transmitted regularly from the device. User this option to set a time
period for receiving supervision signals. If the Control Panel fails to receive supervision
signal from a device within this duration, it will consider the device out of order and
report the event accordingly.
Entry Delay 1 for Full Arm
: Set Entry Delay Timer 1 for full arm mode. When a sensor
set to Start Entry Delay 1 is triggered under Full Arm mode, the control panel will begin
Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Entry Delay 2 for Full Arm
:
Set Entry Delay Timer 2 for full arm mode. When a sensor
set to Start Entry Delay 2 is triggered under Full Arm mode, the control panel will begin
Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Exit Delay for Full Arm
: Set the Exit Delay Timer when entering Full Arm mode. When
the user changes system mode to Full Arm, the panel will begin Exit Delay Timer
Countdown and enter Full Arm mode when the timer expires. The user must leave area
protected by sensors before the timer expires, otherwise an alarm will be activated with
the sensor is triggered.
Entry Delay 1 for Home Arm
: Set Entry Delay Timer 1 for Home Arm mode. When a
sensor set to Start Entry Delay 1 is triggered under Home Arm mode, the control panel
will begin Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Entry Delay 2 for Home Arm
:
Set Entry Delay Timer 2 for Home Arm mode. When a
sensor set to Start Entry Delay 2 is triggered under Home Arm mode, the control panel
will begin Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Exit Delay for Home Arm
: Set Exit Delay Timer for Home Arm mode. When the user
changes system mode to Home Arm, the panel will begin Exit Delay Timer Countdown
and enter Home Arm mode when the timer expires. The user must leave area protected
by sensors before the timer expires, otherwise an alarm will be activated with the
sensor is triggered (Default as 10 seconds
)
.
Alarm Length
: Set the duration the external siren should sound when an alarm is
activated.
Cross Zone Timer
: Please refer to
10.3 Cross Zone Timer
for details
Fire Verification Time
: Please refer to
10.4 Fire Verification Timer
below for details.