triggered.
If bypassed, the system can be armed directly regardless the device’s fault
situation. However, its fault situation will still be monitored, logged and displayed
in the webpage.
Latch report
This function
ONLY
applies to Remote Control or Door Contact with Set/Unset attribute
enabled.
Latch Report
ON:
When the device is used to change systm arm mode, the
Control Panel will report the arm/disarm action by the particular device.
Latch Report
OFF:
When the device is used to change systm arm mode, the
Control Panel will not report the arm/disarm action by the particular device.
Set/Unset
This function is for Door Contact only. This function allows Door Contact to control
system mode.
Normal Close:
The system will be armed when the Door Contact is opened, and
disarmed when Door Contact is closed.
Normal Open
: The system will be armed when the Door Contact is closed, and
disarmed when Door Contact is open.
24HR
This function enables the device to activated selected alarm event whenever it is
triggered regardless of system mode. System mode response will be disabled if 24HR
attribute is enabled.
System Mode Attributes:
The System Mode Attributes determines system behavior under particular arming mode
when the sensor is triggered.
No Response
When a sensor with
No Response
is triggered, the Control Panel will not
respond.
Start Entry Delay 1/ Start Entry Delay 2
When the system is under Full Arm or Home Arm mode, if a sensor with
Start
Entry Delay 1/2
attribute is triggered, Control Panel will start an entry countdown
period to give enough time to disarm the system.
When the Control Panel is in the Disarm mode, if a sensor with
Start Entry Delay
1/2
attribute is triggered, the Control Panel will immediately report a burglar
interior alarm (
CID code: 132
).
When the Control Panel is in the Full Arm mode, if a sensor with
Start Entry
Delay 1/2
attribute is triggered, the Entry Delay 1/2 timer starts counting down.
If no correct pin code is entered during the entry delay timer to disarm the system,
the Control Panel will report a burglar perimeter alarm (
CID code:131
)
immediately after entry delay timer 1/2 expires.
When the Control Panel is in the Home Arm 1/2/3 mode, if a sensor with
Start
Entry Delay 1/2
attribute is triggered, the Entry Delay 1/2 timer starts counting
down. If no correct pin code is entered during the entry delay period to disam
the system, the Control Panel will report a burglar interior alarm (
CID code: 132
)
immediately after entry delay timer 1/2 expires.
19