13
Alarm activated by pressing a button
cannot be cancelled after the Guard Time is
elapsed.
<NOTE>
The Guard Time Delay time from
pressing the Active Button on a Fall
sensor is determined by Command #42
instead of Command #66.
The Guard Time Delay from a fall
detection (of a Fall Sensor) is set by
Command #66
.
Command 43
Periodic Test Call
CTC-1052-QT can be programmed to make
test calls periodically from (00) (no test call)
to every (1) - (7) or 30 days:
Function Selection
Result
(0)
OFF
(1) - (7)
1 - 7 DAYS
(8)
30 DAYS
Factory Default is set as (
0
),
OFF
.
<NOTE>
Whenever programming mode is
accessed, CTC-1052-QT will reset the
Periodic Test Call timer.
Periodic Test Call will only function with
telephone numbers assigned to
SMS
reporting method in
Command 20-24.
Command 44
Mobility Timer
This function monitors user movement around
the premises and sends an inactivity report to
the Monitoring Center if the user fails to reset
the inactivity timer.
This will disable or enable the Inactivity Timer
with selectable count down periods. Options
are:
Function Selection
Result
(00)
DISABLE
(01)
1HR
(02)
2HR
...
....
...
...
....
..
(36)
36HR
Factory Default is set as (
00
),
DISABLE
.
<NOTE>
The Mobility Timer counting down can
be reset by:
1.
Pressing the
Test/Reset Button
on
CTC-1052-QT, or,
2.
Movement
detected
by
PIR
Detector
3.
Only workable by entering 2 digits.
When Mobility Timer expires and no
reset signal is received, CTC-1052-QT
will start to emit one long beep every 5
minutes to alert the user. After 30
minutes, if reset signal is not received,
a mobility alarm reporting will be made.
The reporting method for mobility alarm
is the same as the emergency alarm.
The report will be sent based on your
reporting methods without guard time
waiting.
When (
00
) is selected, no code is sent
to Monitoring Center.
When CTC-1052-QT is in idle mode,
press and hold the Multi-function
Button for 15 seconds, until you hear a
long beep. Release the button and the
Mobility timer will be stopped.
Command 45
Follow-On Mode Choice
This Command is only available when
Command #38 is set as (
0
) or (
2
).
It is used to select the Follow-On Choice for
CTC-1052-QT after it has made a report to
the Monitoring Center.
After reporting, CTC-1052-QT can wait for
further commands, or enter a Two-Way Full