19
R e s i d e n t i a l H & V - 6 0 H z H F C - 4 1 0 A
R e v. : 9 M a r c h , 2 0 1 1 B
c l i m a t e m a s t e r. c o m
Electrical - Line Voltage
WARNING!
CAUTION!
WARNING!
To avoid possible injury or death due to
electrical shock, open the power supply disconnect switch
and secure it in an open position during installation.
CAUTION!
Use only copper conductors for fi eld installed
electrical wiring. Unit terminals are not designed to accept
other types of conductors.
Standard TS Unit
TS Unit with ClimaDry
Model
Compressor
HWG
Pump
FLA
Ext
Loop
Pump
FLA
Fan
Motor
FLA
Total
Unit
FLA
Min
Circuit
Amps
Max
Fuse/
HACR
(2)
ClimaDry
Pump
FLA
Total
Unit
FLA
Min
Circuit
Amps
Max Fuse/
HACR (2)
RLA
LRA
Qty
PSC Electrical Data
018
9.0
48.0
1
0.40
4.0
1.0
14.4
16.7
25
0.8
15.2
17.5
25
024
12.8
60.0
1
0.40
4.0
1.1
18.3
21.5
30
0.8
19.1
22.3
35
030
13.5
61.0
1
0.40
4.0
1.4
19.3
22.7
35
0.8
20.1
23.5
35
036
14.7
72.5
1
0.40
4.0
2.1
21.2
24.9
35
0.8
22.0
25.7
40
042
15.4
83.0
1
0.40
4.0
2.1
21.9
25.8
40
0.8
22.7
26.6
40
048
20.5
109.0
1
0.40
4.0
3.0
27.9
33.0
50
1.07
29.0
34.1
50
060
26.9
145.0
1
0.40
4.0
4.9
36.2
42.9
60
1.07
37.3
44.0
70
ECM Electrical Data
018
9.0
48.0
1
0.40
4.0
3.9
17.3
19.6
25
0.8
18.1
20.4
25
024
12.8
60.0
1
0.40
4.0
3.9
21.1
24.3
35
0.8
21.9
25.1
35
030
13.5
61.0
1
0.40
4.0
3.9
21.8
25.2
35
0.8
22.6
26.0
35
036
14.7
72.5
1
0.40
4.0
3.9
23.0
26.7
40
0.8
23.8
27.5
40
042
15.4
83.0
1
0.40
4.0
3.9
23.7
27.6
40
0.8
24.5
28.4
40
048
20.5
109.0
1
0.40
4.0
6.9
31.8
36.9
50
1.07
32.9
38.0
50
060
26.9
145.0
1
0.40
4.0
6.9
38.2
44.9
70
1.07
39.3
46.0
70
070
30.1
158.0
1
0.40
4.0
6.9
41.4
48.9
70
1.07
42.5
50.0
80
Table 4a: Tranquility
®
27 (TT) Series Electrical Data
Table 4b: Tranquility
®
20 (TS) Series Electrical Data
Rated Voltage of 208-230/60/1
Min/Max Voltage of 197/254
HACR circuit breaker in USA only
All fuses Class RK-5
All TT Units with Emerson ECM Fan Motor
TT Units (ECM) Standard
TT Units (ECM) with ClimaDry
Model
Compressor
HWG
Pump
FLA
Ext
Loop
Pump
FLA
Fan
Motor
FLA
Total
Unit
FLA
Min
Circuit
Amps
Max
Fuse/
HACR
(2)
ClimaDry
Pump
FLA
Total
Unit
FLA
Min
Circuit
Amps
Max/
Fuse
HACR
(2)
RLA
LRA
Qty
026
10.3
52.0
1
0.40
4.0
3.9
18.6
21.2
30
0.8
19.4
22.0
30
038
16.7
82.0
1
0.40
4.0
3.9
25.0
29.2
45
0.8
25.8
30.0
45
049
21.2
96.0
1
0.40
4.0
6.9
32.5
37.8
50
1.07
33.6
38.9
60
064
25.6
118.0
1
0.40
4.0
6.9
36.9
43.3
60
1.07
38.0
44.4
60
072
27.2
150.0
1
0.40
4.0
6.9
38.5
45.3
70
1.07
39.6
46.4
70
Rated Voltage of 208-230/60/1
Min/Max Voltage of 197/254
HACR circuit breaker in USA only
All fuses Class RK-5