www.climacoolcorp.com
42
Automatic CS Series Strainer Package
Field installed,
high quality, low maintenance stainless steel
filtration systems with 60 or 80 mesh stainless steel screens
will reduce operating costs and prevent nuisance condenser
issues. Strainer package can be equipped with optional
pressure differential alarm and automatic time flush.
Heat Pump
Factory installed reverse cycle heating and cooling operation
compatible with boiler/tower or geothermal systems .
Heat Recovery
Factory installed option providing hot water, as high as
140°F, while simultaneously producing chilled water for the
chiller system .
Hot Gas Bypass
Factory installed on both circuits allowing unit operation
below the minimum step of unloading .
Manual Strainers
Field installed strainers
utilize Y-style and Basket strainers
of cast iron 200 psi or carbon 275 psi with 60 mesh stainless
steel screens to increase efficiency and ensure long
equipment life. All strainers are field installed external to the
chiller bank for ease of service.
Motorized or Manual Water Isolation Valves
and Flush Ports
Factory installed water isolation valves and flush ports
shall provide isolation to the module for maintenance and
cleaning of evaporator and condenser heat exchangers
while adjacent modules continue normal operation . Both
motorized and manual valves include standard ¾” fill and
flush valves.
Note: All Heat Pump configurations require
motorized valves.
Motorized condenser water valves provide head pressure
regulation for low entering condenser water temperature
applications (less than 60°F).
Available choices include:
• One each motorized valve for evaporator and
condenser with one each manual valves for the
evaporator and condenser .
• One each motorized valve for the evaporator and one
each manual valve for the evaporator and two each
manual valves for the condenser .
• Two each manual valves for the evaporator and
the condenser .
Pressure Differential Flow Sensor
Field installed to prevent operation of chiller without
sufficient water flow to the evaporator and/or condenser.
Seismic Certification
Factory installed seismic tested in accordance with OSHPD
standars for cooling only chillers .
Water Header Bypass
Field installed water header bypass may be utilized to
prevent deadheading the pump. A bypass is mandatory with
all motorized valve applications.
Options available for following:
Direct Return:
• Motorized evaporator/condenser water
isolation valves
• Motorized evaporator/manual condenser water
isolation valves
Reverse Return:
• Motorized evaporator/condenser water
isolation valves
• Motorized evaporator/manual condenser water
isolation valves
Options and Accessories
Содержание UCH 30
Страница 16: ... www climacoolcorp com 14 Voltage Phase Monitor Wiring ...
Страница 21: ...19 www climacoolcorp com Figure 23 Part Load Performance Advantage ...
Страница 57: ...55 www climacoolcorp com Wiring Diagrams 030 050 070 Cooling Only ...
Страница 58: ... www climacoolcorp com 56 Wiring Diagrams 030 050 070 Cooling Only ...
Страница 59: ...57 www climacoolcorp com Wiring Diagrams 030 050 070 Heat Pump ...
Страница 60: ... www climacoolcorp com 58 Wiring Diagrams 030 050 070 Heat Pump ...
Страница 61: ...59 www climacoolcorp com Wiring Diagrams 085 Cooling Only ...
Страница 62: ... www climacoolcorp com 60 Wiring Diagrams 085 Cooling Only ...
Страница 63: ...61 www climacoolcorp com Wiring Diagrams 085 Heat Pump ...
Страница 64: ... www climacoolcorp com 62 Wiring Diagrams 085 Heat Pump ...
Страница 65: ...63 www climacoolcorp com Wiring Diagrams Master Panel ...
Страница 66: ... www climacoolcorp com 64 Wiring Diagrams Master Panel ...
Страница 70: ... www climacoolcorp com 68 Notes ...
Страница 71: ...69 www climacoolcorp com Notes ...