25
© 2008 Directed Electronics. All rights reserved.
5
BLUE/WHITE
(-) 200 mA 2ND STATUS/REAR DEFOGGER
This wire supplies a 200mA output as soon as the module begins the remote
start process. The Blue/White wire can also be used to activate the defogger
trigger (latched/pulsed) 10-seconds after the remote start engages. (See the
Feature Descriptions, Menu#3, feature #11 for details about programming this
output).
➢
Remote start auxiliary output, 5-pin
These signals are provided to drive additional optional relays.
1
PINK/WHITE
(-) 200mA FLEX RELAY CONTROL OUTPUT
This wire is programmed as (-) 2nd ignition output from factory and can be pro-
grammed (to drive a relay) as a (-) starter or an accessory output.
2
ORANGE
(-) 200mA ACCESSORY OUTPUT
This wire works like the main accessory wire and can be used (with a relay) to
drive any additional accessory circuits in the vehicle.
3
VIOLET
(-) 200mA STARTER OUTPUT
This wire works like the starter wire and can be used (with a relay) to drive any
additional starter circuits in the vehicle.
4
PINK
(-) 200mA IGNITION 1 OUTPUT
This wire works like the ignition 1 wire and can be used (with a relay) to drive
any additional ignition circuits in the vehicle.
Note:
Wires 1 - 4 on the remote start auxiliary outputs are wired to the (-) triggers
for the onboard remote start relays and are not diode isolated. If connecting
these wires directly to the vehicle you must place a 1-amp diode in line to pre-
vent feedback from the vehicle.
Содержание CLIFFORD 50.7X
Страница 63: ......
Страница 64: ...N5702X 2008 08 Vista CA 92081 www directed com 2008 Directed Electronics All rights reserved ...