Click RF PiLOT Скачать руководство пользователя страница 4

5

4

RF Pilot Characteristics

  The RF Pilot Remote Controller of the RF Control wireless system enables 
  intelligent control of RF units.

  - 

Sending commands to switching, dimming and blind/shutter actuators/receivers

    - RF Pilot measures and displays the local surroundings temperature
    - The RF Pilot controller can be programmed with up to 40 actuators/receivers
    - You can create your own menus and name the RF Pilot controlled devices as required
    - The “Scene” mode enables control of multiple actuators - multiple devices controlled with a single 
          press (up to 10 scenes each controlling 10 actuators)
    - You can include the most frequently used devices/scenes in your “Favourite” menu and control them 
          immediately after switching on the RF Pilot
    - Range up to 200m
    - Operates on the frequency 868.5 Mhz

    - Colour: anthracite
    - Battery supply 2 x AAA with life cycle up to 3 years

Other data

Operating 
temperature:

0 .. +55 °C

Storage 
temperature:

-20 ..+70 °C

Protection:

IP20

Working position:

Any

Dimensions:

130 x 41 x 18 mm

Weight:

61 g

Related 
standards:

EN 60730, EN 300 220, EN 301 489

RTTE Directive, Gov. Reg. No. 

426/2000Sb (Directive1999/EC)

Display

Type:

Colour OLED

Resolution:

128 x 128 pixels / 262,144 colours

Side ratio:

1:1

Visible surface:

26 x 26 mm

Backlight:

self-illuminating text

Diagonal:

1.5“

Control:

direction button, control buttons

Power supply

Power supply:

2 x batteries 1.5V AAA *

Service life:

approx. 3 years, according to the 

frequency of use and battery type

Control

Range in open 
area:

 to 200 m

Frequency:

868.5 MHz

Technical parameters

* batteries are included.

Characteristics

Technical Parameters

Содержание RF PiLOT

Страница 1: ...4 0 C h a n n e l R e m o t e C o n t r o l W i t h O L E D D i s p l a y Installation Manual 26 03 2014 16 29 23...

Страница 2: ...junction with other RF Control devices the RF Pilot offers you Comfortable handheld control Activation of household appliances and devices Light dimming and creation of light scenes Control of blinds...

Страница 3: ...d you become aware of any signs of damage deformation malfunction or of any missing parts do not install this product and return it to the vendor After the expiry of its service life the product and a...

Страница 4: ...immediately after switching on the RF Pilot Range up to 200m Operates on the frequency 868 5 Mhz Colour anthracite Battery supply 2 x AAA with life cycle up to 3 years Other data Operating temperatur...

Страница 5: ...ntrol devices with 0 1 10V dimmable input Analogue Actuator Dim Pack DIM 6 2000Va dimming pack with 0 1 10V input and momentary switch input de rate for LED loads Becomes wireless when used in conjunc...

Страница 6: ...ll remain After inserting the batteries the RF Pilot name and the firmware version will appear on the initial screen as shown above To set the Date and Time elements see page 14 Current Temperature Di...

Страница 7: ...cenes The 10 most commonly used actuators and scenes can be selected in to the favourites quick control menu The favourites appear on the initial screen and activated with just a couple of clicks Step...

Страница 8: ...hilst in the Control Menu The programming menu can only be accessed from the control menu with pressing the left side of the dial and T1 together Programming Menu Language setting With language highli...

Страница 9: ...ourites Device reset EXIT SELECT Fig 1 T1 T2 T1 T2 T1 T2 The RF Pilot automatically arranges the names of Rooms 1 10 in order Within the programming menu you can rename or reset the name to factory co...

Страница 10: ...1 12 54 Name Room 1 Rename Reset EXIT SELECT Fig 5 T1 T2 T1 T2 T1 T2 T1 T2 In the Programming Menu select Actuators Fig 6 Press the T1 button to enter the menu Add To add an actuator to the RF Pilot C...

Страница 11: ...oom 7 EXIT Allocate Fig 3 Programming Actuators Rename Fig 6 Used to change the name of the actuator the name will then be displayed in the menu list under the Room Control function Using up down on t...

Страница 12: ...Range test Control Remove EXIT SELECT Fig 4 T1 T2 T1 T2 T1 T2 tu 01 03 11 12 54 EXIT START Fig 3 Memory 1 40 Type address RFSA6x 012345 Room Lounge Name Lamp EXIT SELECT Fig 2 tu 01 03 11 12 54 Add A...

Страница 13: ...g Actuator Functions Description Turn On Actuator switched On Turn Off Actuator switched Off Brightness 0 Brightness setting within the range 0 100 10 steps using left right buttons Slowly On Graduall...

Страница 14: ...11 12 54 Turn On Turn Off Brightness 0 White RGB BACK PROCEED Fig 1 T1 T2 tu 01 03 11 12 54 Turn On Turn Off Brightness 0 White RGB BACK PROCEED Fig 2 T1 T2 T1 T2 Select the required function highlig...

Страница 15: ...ene 3 Scene 4 Scene 5 Scene 6 Scene 7 EXIT SELECT Fig 2 tu 01 03 11 12 54 Name Scene 1 Rename Commands Reset BACK PROCEED Fig 3 Programming Scenes Rename Fig 4 Used to change the name of the scene the...

Страница 16: ...T Fig 3 Programming Scenes Scenes Commands Scenes Commands continued T1 T2 Command 1 10 Room Unassigned Actuator Unassigned Action Unassigned BACK ASSIGN Fig 2 T1 T2 tu 01 03 11 12 54 Turn On Turn Off...

Страница 17: ...igned Action Unassigned BACK ASSIGN Fig 1 Commands LED RGB controller After each actuator and function has been added to a command the screen will move to the next command 3 10 etc automatically Fig 1...

Страница 18: ...nguage Date and time Actuators Rooms Scenes Favourite Device reset EXIT SELECT Fig 1 T1 T2 tu 01 03 11 12 54 Name Favourite 1 Assign Cancel BACK SELECT Fig 3 Programming Favourite T1 T2 Assign Used to...

Страница 19: ...1 12 54 Reading Scene 2 Scene 3 Scene 4 Scene 5 Scene 6 Scene 7 EXIT SELECT Fig 7 T1 T2 tu 01 03 11 12 54 Turn On Turn Off EXIT ASSIGN Fig 4 T1 T2 tu 01 03 11 12 54 Centre Light F Favourite 2 Favourit...

Страница 20: ...avourite 5 Favourite 6 Favourite 7 Temp 23C MENU Fig 3 tu 01 03 11 12 54 Favourite 1 Favourite 2 Favourite 3 Lamps Favourite 5 Favourite 6 Favourite 7 Temp 23C MENU Fig 4 Initial Screen Quick Control...

Страница 21: ...actuator s has have not confirmed executing the command please repeat the command If the error persists The actuator has accepted and executed the command RF Pilot has not detected any execution feed...

Страница 22: ...posed of in accordance with local environmental regulations Batteries accumulators Batteries must never be disposed within household waste They may contain poisonous substances harmful to the environm...

Страница 23: ...35 36 37 38 39 40 Number Location Identification 12 Chars Name of Controlled Load 12 Chars Actuator Part No Actuator Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 A4 version can be downl...

Страница 24: ...Notes Notes...

Страница 25: ...fordshire B79 7XB Tel 01827 63454 Fax 01827 63362 sales scolmore com www scolmore com V10 0 18 Corrig Road Sandyford Industrial Estate Dublin 18 Ireland Tel 353 1 2811 122 Fax 353 1 2811 224 sales cli...

Отзывы: