14
AIR PRESSURE
1.
Adjust air regulator or line pressure so that air pressure
gauge reads 90 - 100 psi when unit is running on
continuous cycle (stroke selector switch is set on
"constant pumping").
2.
Drip Adjustment -
Þ
Observe the sight bulb on the top of the oiler. One
drop of oil into the lines for every ten to fifteen cycles of
the product piston.
Þ
If adjustment is necessary turn the sight bulb
clockwise for more oil, counter clockwise for less oil.
3.
Adding Oil -
Use only mineral oil in th oiler.
Þ
Remove air supply from unit.
Þ
Remove oiler bowl (as per instructions on the bowl).
Fill to line and replace.
AIR FILTER REPLACEMENT
PROCEDURE
The air filter is designed to
separate a small amount of dirt
and water from the supply air.
This filter is NOT designed to
clean air straight from the
compressor. You must install a
separate filter and drier in the
supply line to deliver air with a
dew point of less than 65° F.
1.
Check for water accumulation daily. If water is present,
push small button at the bottom of bowl and allow the
water to spray out.
NOTE:
If the bowl has to be drained regularly (more than
once a week) then the supply air has not been sufficiently
dried.
2.
If the air filter cartridge is dirty then it should be
replaced.
Þ
Turn off air to the unit.
Þ
Remove bowl.
Þ
Separated deflector and baffle
Þ
Install new filter.
Þ
Reassemble.
STROKE ADJUSTMENT
The amount of delay between the time the product piston
reaches the end of a half stroke and the reversing of
direction can be adjusted.
1.
The two flow controls (LV1 & LV2) are located to the left
of the product piston.
2.
Loosen locking nut.
3.
Set selector switch to continuous and have someone
hold the nozzle trigger as you adjust the delay.
4.
Retighten the locking knob.
The product piston stroke can be adjusted by loosening the
knob and moving the limit switch LV1. Move to left to shorten
the stroke or the right to increase.
Deflector
Filter
Element
Baffle
Lever
Bowl/Guard
Assembly
Oil Sight Bulb
and Adjuster
Oil
Bowl
Cleanout Button
Air Regulator Dial
Pressure
Gauge
Water
& Dirt
Cleanout