CE-400 Series Label Shrinking Machines
Page
13
9.
In order to prolong the life of heating pipes, do the right operation according
to following step:
a)
While start machine, put on the heating device and hot fan together at the
same time.
b)
While stop machine, put off the heating device first and let fan run for a while
to cool down.
10.
Check the carbon brush of fan motor when the speed of motor is getting
slower; carbon brush wears off gradually during usage, so check up the carbon brush
often, which is found under a small cap; Replace it if carbon brush uses up, and clean
up brush powder inside of motor.
IX. COMMON MALFUNCTION
Case
Cause
Method
No heat in the tunnel
No power
Put on the power
Heating switch broken
Replace
Heating pipe or circuitry broken
Replace or repair
AC contactor, Solid-booster or temp. meter
broken
Replace
Heating adjustment is in the lowest position
Adjust
The temp. of the tunnel
is too low
Some heating pipes broken
Replace
Heat adjustment is too low
Increase
The temp. is set too low
reset
One of the 3 fire wires loose
Re-connect
Conveyor motor stop
running
Switch or Adjuster broken
Replace
The motor burned
Replace
Conveyor adjustment is in the lowest position
Adjust
Block on the driving unit
Adjust or mend
The fan motor does not
work
The switch of the fan broken
Replace
The motor of the fan broken
Replace
Circuitry broken
Mend
Stop suddenly
Power loose or fuse pipe broken
Replace
Содержание CE-400 Series
Страница 1: ...400 Series Label Shrinking Machine Operation Manual...
Страница 5: ...CE 400 Series Label Shrinking Machines Page 4 IV STRUCTURE DIAGRAM 1 CE 435...
Страница 6: ...CE 400 Series Label Shrinking Machines Page 5 2 CE 455...
Страница 7: ...CE 400 Series Label Shrinking Machines Page 6 3 CE 415...
Страница 8: ...CE 400 Series Label Shrinking Machines Page 7 4 CE 425...