Models 24-CGA-10, 24-CGP-10, 24-CEA-10, 24-CEP-10
SteamCraft 10 Service Manual, Chapter 3
Page 51
All seconds method: Change the 1.5 minutes to 90 seconds and press
9 0. The display reads 00:90 when set for 1.5 minutes. When the timer
starts, the display automatically changes to minutes and seconds
(01:30).
6. Press the START/STOP key to start the timer. When the START/STOP
key is pressed, the steam generator begins heating the water to steam.
Shortly, steam fills the cooking compartment.
a. The timer displa y reads PAUS until the cooking compartment
reaches proper cooking temperature.
b. When the cooking compartment reaches proper cooking
temperature, the timer display shows the count down.
NOTE:
A timer setting of 10 minutes in fact take 11 or 12 minutes for
the timer to count down and the alarm to sound. This is
normal. Heating the compartment and food to cooking
temperature uses the additional time.
c. To stop or reset the timer, press and hold the START/STOP key.
The cooking time display returns to the last time setting.
• To restart the same time, press the START/STOP key.
• To set a new time, press and hold the CLEAR key and set the new
time.
7. When the timer counts down to zero, the alarm sounds continuously, the
generator stops steaming, and steam flow to the cooking compartment
gradually stops.
8. Press the START/STOP key to silence the alarm. The cooking time
display returns to the last time set. Either run this same setting again or
clear and reset the timer.
Example
3. Cook two 14 minutes cycles.
a. Press and hold the CLEAR key to clear the timer.
b. Press the following number keys in sequence: 1400. The display
shows 14:00.
c. Press the START/STOP key to start the timer. When the display
counts down to zero, the alarm sounds.
d. Press the START/STOP key to stop the buzzer and the display
returns to 14:00.
e. Press the START/STOP key to start the second 14 minute cycle.
Manual Cooking Procedure
CAUTION
Steam leaks around the door, cooking compartment
flooding, reduced cooking performance, and
compartment implosion can be caused by a blocked
drain or drain screen. Inspect and clean the drain and
drain screen before each use.