Models 24-CGA-10, and 24-CEA-10
SteamCraft 10 Service Manual, Chapter 6
Page 137
CT:13 Mechanical Timer
CT:14 & CT:15 3-Second Timer and Buzzer
(mechanical timer units only)
Cleveland Range, Inc.
Prin ted 3/93
Figure 6-30. Mechanical Dial Timer
1. Set the voltmeter to the 250 VAC scale.
2. Set the ON/OFF switch to the ON position.
3. Set the TIMED/MANUAL switch to the MANUAL position. Operate the
SteamCraft 10 for about 10 minutes, or until it is steaming continuously.
4. Set the TIMED/MANUAL switch to the TIMED position, and zero the timer.
5. Check for 115/120 VAC across timer terminals L1-T1, and 0 VAC across timer
terminal L1 -T3.
• If the meter reads 115/120 VAC across L1-T1 and 0
VAC
across L1-T3,
continue this procedure with step 7.
• If the meter reads 0 VAC across L1-T1, the contacts L1-T1 are shorted within
the timer. Replace the dial timer.
• If the meter reads 115/120 VAC across L1-T3, the contacts L1-T3 are open
within the timer. Replace the dial timer.
6. Set the timer dial to 10 minutes. Refer to Figure 6-30. Check for 0 VAC across
timer terminals L1-T1, and 115/120 VAC across timer terminals L1-T3.
• If the meter reads 0 VAC across L1-T1 and 115/120
VAC
across L1-T3, the
dial timer is good. End this procedure here.
• If the meter reads 115/120 VAC across L1-T1, replace the dial timer.
• If the meter reads 0 VAC across L1-T3, replace the dial timer.
1. Set the voltmeter to the 250 VAC scale.
2. Set the ON/OFF switch to the ON position.
3. Set the TIMED/MANUAL switch to the MANUAL position.
4. Refer to Figures 6-31, 6-32, 6-33, and 6-44 and connect the voltmeter leads
across timer terminals 1-3 (LOAD).
5. Set the TIMED/MANUAL switch to TIMED, and check for 115/120 VAC
across timer terminals 1-3 (LOAD).
• If the meter reads 115/120 VAC across the test points, continue this
procedure with step 7.
• If the meter
does not read 115/120 VAC across the test points, continue this
procedure with step 6.
6. Refer to Figures 6-31, 6-32, 6-33, and 6-44 and connect the voltmeter leads
across timer terminals 2-3 (INPUT). Check for 115/120
VAC
across the test
points.
• If the meter reads 115/120 VAC across the test points, replace the 3-second
timer.
Figure 6-31. 3-Second Timer and Buzzer
Upper Compartment - 24-CEA-10