Page 144
SteamCraft 10 Service Manual, Chapter 6
Models 24-CGA-10 and 24-CEA-10
CT:22 High Temperature Limit Switch
Model 24-CEA-10
1. Refer to Figure 6-42. Set the voltmeter to the 250 VAC scale.
2. Set the ON/OFF switch to the ON position.
3. Before proceeding to step 4, wait until water fills the float cylinder to
normal operating level.
4. Set TIMED/MANUAL switch to MANUAL. Check that the heater
contactor energizes: 120
VAC
from the heater contactor brown wire
connection to the heater contactor white/brown wire connection on the
top compartment and 120 VAC from the heater contactor yellow wire
connection to the heater contactor white/yellow wire connection on the
bottom compartment.
• If the meter reads 120 VAC, the high temperature limit switch is good.
End this procedure here.
• If the meter does not read 120 VAC, continue this procedure with step 5.
5. Check for 120 VAC across the high temperature limit switch terminals.
• If the meter reads 120 VAC, replace the high temperature limit switch.
• If the meter reads 0 VAC continue this procedure with step 6.
6. Check for 120 VAC from the TIMED/MANUAL switch orange wire
connection to the ON/OFF switch red wire connection.
• If the meter does not read 120 VAC between these test points, test the
TIMED/MANUAL switch.
• If the meter reads 120 VAC between these test points, the fault is not in
the high temperature limit switch.
a. On the top compartment check the black and brown wires to the high
temperature limit switch, float assembly, and the contactor for
Figure 6-42. High Limit Switch Assembly
24-CEA-10
Printed
3/93
Cleveland Range,
Inc.