39
B
2
1
4
3
C
A
English
English
Installation example, Fig. A
Walled in whirlpool installation
Ventilation and service are ensured by an
opening in the neighbouring room (1) or in the
tub enclosure (2).
Note:
Do not connect the thermostat with fl exible
pressure hoses!
Installation example, Fig. B
Laid on whirlpool installation
Ventilation ensured by ventilation hatch (3).
Service possible by lifting out the complete
whirlpool.
Note:
-
Make sure during the installation that the
connections (electricity, water, drain) can
be connected and disconnected through
the ventilation hatch (3)!
-
It must be possible to disconnect the
attachment points through the ventilation
hatch (3).
-
It must be possible to lift out the complete
whirlpool upward out of the embedding
for service purposes! Caution when
installing the whirlpool under a pitched
roof!
-
The tub must be sealed at the edge (4)
with silicone (free from acetic acid).
Note:
If the tub is walled in or otherwise enclosed, a
safety hatch must be present in the lower area
of the enclosure according to the EN 60335-1
regulations so that, when a leak occurs under
the tub, the water can be seen to fl ow away.
The bottom edge of the safety opening must be
20 mm below the electrical assemblies of the
whirlpool tub (Fig. C)!
Whirpool installation / Examples
Содержание Luxusline Duo Imaza 750
Страница 2: ...2...
Страница 35: ...35 5 16 17 18 1 2 3 8 4 6 7 9 10 11 12 15 14 13 English English Equipment...
Страница 75: ...75 97308000 English Service Replacement of rechargeable battery in the Poolkontrol...
Страница 77: ...77 English Declaration of performance...
Страница 78: ...78 Declaration of performance...
Страница 79: ...79 English English Declaration of conformity...