Troubleshooting
Error
Possible causes
Measures and remedies
Tool too strong
Torque set too high
Reduce the torque setting, see
4.4.2 Changing Torque, page 10
Tool too weak
Working pressure too low
Check the cross section of the
hose and coupling: Inner
diameter 3/8" (ø 9.5 mm), maxi-
mum length 5 m
Increase the working pressure.
Reverse button is
not at the detent
Turn the reverse button
to the detent
Excessive transmission damping due
to extension and worn socket.
Increase the speed, see 4.4.1 Set-
ting the torque, page 10.
Use a shorter or more rigid exten-
sion.
Replace the socket
Insufficient oil in the pulse unit (no
pulse build-up)
See 5.2 Fill reserve oil, page 14
Screen in the air inlet tube /
muffler is dirty
Clean or replace parts
Accuracy insufficient
Adapter parts
Replace adapter parts
Use extension and socket with
guide diameter
Pressure fluctuations in the air network
Use a pressure regulator
Premature release of the start button
Keep start button pressed until nut-
setter has stopped rotating
Fastening time too
long: > 4 seconds
Joint too soft; crush nuts, self-tapping
screws
Increase the speed
Use a pulse nutsetter with a higher
capacity.
Содержание 7PHH
Страница 12: ...12 P1990BA EN 2014 06 1994b_1_5_en bedingt fm 12 06 2014 Before initial operation 4...
Страница 18: ...18 P1990BA EN 2014 06 1994c_Wartung_en bedingt fm 12 06 2014 Maintenance 5 Empty side...
Страница 24: ...24 P1990BA EN 2014 06 1994d_Reparatur_en bedingt fm 12 06 2014 Assembly instructions 7...
Страница 34: ...34 P1990BA EN 2014 06 1990e_Ersatzteile_en fm 12 06 2014 Spare parts 8 8 5 Equipment order list 1 Order no...
Страница 36: ...36 P1990BA EN 2014 06 1990f_TechnDaten_en fm 12 06 2014 Technical data 9 9 2 Dimensions 7PHHA in mm Abb 9 2...
Страница 38: ...38 P1990BA EN 2014 06 1990f_TechnDaten_en fm 12 06 2014 Disposal 11...