1994c_Wartung_en-bedingt.fm, 12.06.2014
P1990BA/EN 2014-06
17
Maintenance
5
5
Uncouple the pulse unit and unscrew the
adapter.
To avoid air pockets, fill the filling hole full of oil.
6
Position the injector so that it has a sealing
effect and add reserve oil until distance
X
for
spacer
<B2>
is achieved.
Maintain distance
X
and secure with
<B2>
.
Refit set bolt and ball.
Remove
<B2>
.
NOTE
Small air bubbles that become visible due to the high pressure during filling do not mean that the pulse unit
is leaking. This will not negatively affect the filling result.
<B1>
<B2>
Approx. 5 ml
X
approx. 2.5 mm