86b_1_5 en bedingt.fm, 24.07.2008
P1886E/EN 2008-07
9
Before initial operation
4
4
Before initial operation
4.1
Ambient conditions
4.2
Air supply
➔
The inside of the air hose must be free of residue; clean it if necessary.
➔
Spray a few drops of light oil into the air inlet tube.
Oils according to DIN 51524 / ISO 3498
4.3
Changing air inlet: top / buttom (120PTHDA only)
At delivery the air inlet at the buttom is sealed with a screwed plug. If a change is required,
change following:
➔
Remove air strainer from the top (and store it). See demand 8.2 Pistol grip 120PTHDA…,
page 28, see detail X.
➔
Remove screwed plug from the buttom, thereby holding fast A/F 17.
➔
Screw screwed plug into air inlet at the top.
Ambient temperature
41 °F (5 °C) to a maximum of +104 °F (+40 °C)
Permissible relative humidity
25 to 90 %, non-condensing
Parameter
Data
Air hose
Inner diameter 1/2" (ø 12,5 mm),
maximum length 16.4 ft (5 m)
Working pressure range
58 to 101.5 psi (400 to 700 kPa)
Recommended: 90 psi (620 kPa)
Compressed air
Air quality according to ISO 8573-1, quality class 2.4.3
The compressed air must be clean and dry.
NOTE
To attain consistent results, maintain a constant working pressure using a 1/2" service unit con-
sisting of filter, pressure regulator and lubricator.
Order no. Packaging
unit
liter
Designation ARAL
BP
elf
ESSO
INA
Mobil
Klüber
SHELL
933090
2
HL32
Aralub
EE 100
Energol
HL 32
Polyelis 32
Olna 32
Nuto
H 32
Hydraol
A 32
D.T.E.Oil Light
Vactra Oil Light
Crukolan 32
Molina 32
Molina 22