Troubleshooting 

Many operating problems may be solved by carefully reading and following 
the instructions in this manual accordingly. Some suggestions for 
troubleshooting are given below. Should these suggestions not resolve the 
problem, please contact our SERVICE DEPARTMENT or a distributor in your 
region for assistance. If troubleshooting service is required, please include a 
full description of the problem. Contact 

[email protected]

  

Problem 

Solution 

Screen does

n’t light on

 

Check if main power switch is switched on 
There is an LED on the upper right side. Please check if the light is on. If 

not, press “Screen power switch”

 

No Signal from Camera

 

Please check if the camera is turned on. 
Check if power wire to camera is properly connected.  
Check if HDMI cable to camera is properly connected. 

Light  lamp 

doesn’t

  light 

on

 

Check if white light lamp switch is switched on. 

 

 

Содержание CSL-MDOCBASIC

Страница 1: ...MICRODOC ...

Страница 2: ......

Страница 3: ... CSL MDOCUV2541D CSL MDOCUV3651D CSL MDOCUV254 3121D CSL MDOCUV254 3651D CSL MDOCUV312 3651D CSL MDOCBASIC CSL MDOCBASIC1D Record the following for your records Model _____________________ Catalogue No _____________________ Date of Delivery _____________________ Warranty Period _____________________ Serial No _____________________ Invoice No _____________________ Purchase Order No ________________...

Страница 4: ...voiding electrical shock 5 Avoiding Damage to the Instrument 6 UV Tubes Disposal 6 Symbols 6 Packing List 7 Specifications 9 Operating Instructions 10 Installation 10 Connecting to UV transilluminator 11 Camera set up 12 Operation 13 Front Panel 13 Turning on the system 13 Agarose gel Imaging 13 Troubleshooting 15 Ordering information 16 Warranty 17 ...

Страница 5: ...d the following information carefully before operating this equipment 1 Read and follow the manual instructions carefully 2 Do not alter the equipment Failure to follow these directions could result in personal and or laboratory hazards as well as invalidate equipment warranty 3 Use a properly grounded electrical outlet with correct voltage and current handling capacity 4 Disconnect from power sup...

Страница 6: ... as medical device no representation promises express warranty or implied warranty will be made concerning the suitability of these instruments for any medical use Cleaver Scientific will not provide customers any notice or certification concerning its products being compliant as a medical device Installation Safety Use a high level of precaution against any electrical device Before connecting the...

Страница 7: ...thus minimizing any potential shock hazard to the user Cleaver Scientific recommends against the use of unshielded wires To avoid electrical shock 11 In the event of solution spilling on the instrument it must be dried out for at least 2 hours and restored to NORMAL CONDITION before each operation NEVER connect or disconnect wire leads from the power jacks when the power is on 12 WAIT at least 5 s...

Страница 8: ...acturer s instruction to see if the proposed method will damage the equipment UV Tubes Disposal The UV tubes contain mercury Please dispose of the tubes in accordance with local regulations It is important to handle the waste tubes with care to protect public health and the environment Symbols Indicates an area where a potential hazard may exist Indicates a warning of UV radiation UV radiation can...

Страница 9: ...CSL MDOCUV365 Included CSLUVTS65 None Included CSL MDOCUV254 312 Included CSLUVTSDUO312 None Included CSL MDOCUV254 365 Included CSLUVTSDUO None Included CSL MDOCUV312 365 Included CSLUVTSDUO365 None Included CSL MICRODOC1D Included None CLIQS Included CSL MDOCUV3121D Included CSLUVTS312 CLIQS Included CSL MDOCUV2541D Included CSLUVTS254 CLIQS Included CSL MDOCUV3651D Included CSLUVTS65 CLIQS Incl...

Страница 10: ...ceived Cleaver Scientific is liable for all missing or damaged parts accessories within 7 days after customer received this instrument package Please contact Cleaver Scientific immediately regarding this issue If no response within such period from consignee party that will be consignee party s whole responsibility Please contact your supplier if there are any problems or missing items ...

Страница 11: ...Length Maximum Aperture 18 55mm f 3 5 5 6 Lens Canon EF mount Filter Ordered Separately Ethidium Bromide or Blue light 58mm Multi power Source For camera inner light lamp screen Monitor Adjustable Tilt Inner White Light 2 white light LED Safety Door Switch Automatically shut down UV transilluminator while opening the chamber door during operation Dimension with camera 300 x 350 x 510 mm Rated Volt...

Страница 12: ...d on an existing transilluminator microDOC systems are delivered pre assembled and do not require any complex assembly Installation can be achieved in these simple steps 1 Connect the camera to the screen by plugging in the HDMI cable to the screen and camera 2 Connect the power supply to the screen by plugging in the power cable ...

Страница 13: ...ff the UV lights when the microDOC door is opened To connect the microDOC to a UV transilluminator place the microDOC on the UV or blue transilluminator and follow these steps 1 Plug the supplied 3 pin connector into the back of the microDOC as shown 2 Plug the other end of the 3 pin cable into the transilluminator power inlet The microDOC system is now ready to be used with the transilluminator ...

Страница 14: ...n installation If at any point the camera settings are altered use to following instructions to return the camera to the optimum settings for gel documentation 1 Set the camera mode to M on the rotary dial 2 Set the image to monochrome mode a Press the menu button b Navigate to camera options 2 c Under picture style select Monochrome d Return to shooting mode ...

Страница 15: ...o the on position Agarose gel Imaging To Image a fluorescently stained agarose gel follow the steps below 1 Turn on the system camera and transilluminator 2 Ensure the camera mode is set to M as shown previously 3 Press the Live view button to display the camera image on the screen 4 Open the microDOC door if a UV transilluminator is connected this will automatically shut off when the door is open...

Страница 16: ... the focus confirmed noise is heard 11 At high zoom levels the autofocus may struggle to focus in this case change the lens to manual focus by operating the switch on the side of the lens and rotating the focus wheel manually 12 Press button and key to view the pictures on the memory card full frame in the monitor Press button again to return image shooting mode 13 When finished capturing image pl...

Страница 17: ...bleshooting service is required please include a full description of the problem Contact support cleaverscientific com Problem Solution Screen doesn t light on Check if main power switch is switched on There is an LED on the upper right side Please check if the light is on If not press Screen power switch No Signal from Camera Please check if the camera is turned on Check if power wire to camera i...

Страница 18: ...12 CSL MDOCUV254 312 CSL MDOCUV254 3121D microDOC System with UV Transilluminator UVT254 365 CSL MDOCUV254 365 CSL MDOCUV254 3651D microDOC System with UV Transilluminator UVT312 365 CSL MDOCUV312 365 CSL MDOCUV312 3651D microDOC Basic System with lift off dark room hood and camera only CSL MDOCBASIC CSL MDOCBASIC1D Accessories Mitsubishi Thermal Printer for use with PC 110 240V CSL PRINTUSB micro...

Страница 19: ...fication has been performed by anyone other than CSL or an appointed distributor or representative are no longer under warranty from the time the unit was modified Units which have accessories or repaired parts not supplied by CSL or its associated distributors have invalidated warranty CSL cannot repair or replace free of charge units where improper solutions or chemicals have been used If a prob...

Страница 20: ......

Страница 21: ......

Отзывы: