Salt
Always test the salt level before adding salt. Refer to page 18 & 19 for instructions on
adding salt.
Safety Test
After installing the Clearwater chlorinator the following safety test MUST be performed.
Turn on the pool pump and the chlorinator. Adjust the chlorine output to maximum.
Disconnect the blue sensor clip from the terminal pin at the end of the cell. The RED "no
flow" light should be illuminated and the output lights should drop to the minimum, showing a
yellow light only. If this happens, the flow sensor is operating properly. Reconnect the blue
flow sensor clip to resume normal operation.
Do not operate the unit if it fails this test.
Contact Zodiac at 1-888-537-6657 for instructions.