TROUBLESHOOTING
Problem I
Chlorinator stops working, all lights OFF.
CAUSE 1: Unit turned off.
REMEDY:
Push ON/OFF button. A yellow light in the Chlorine Output indicator window is present
when the unit is “ON”.
CAUSE 2: Mains power removed or blown fuse.
REMEDY:
Check mains power source and fuse.
Resetting the Fuse.
Turn off all power to the Clearwater powerpack.The resettable fuse is located above the
powercord on the bottom rear of the LM2 unit. If the fuse is blown (popped with white area
exposed), push to reset. Restore power to unit.
Mains power supply.
Your Clearwater chlorinator must be connected to a properly grounded electrical power
socket, or power source.
Problem J
Chlorine level is too high.
CAUSE 1: Chlorinator is manufacturing too much chlorine.
REMEDY 1:
Use the output button to reduce setting. Retest chlorine daily until proper level is attained.
REMEDY 2:
Manually turn chlorinator off. The LM Series uses a smart switch that turns the chlorinator on
automatically with each pump cycle. If longer periods of zero (0) chlorine output are required,
disconnect the blue sensor clip on cell. (Red NO FLOW light will illuminate once chlorine
production has stopped.) Sensor clip must be reconnected for chlorine production to begin.
Any type of electrical troubleshooting should be handled by a
qualified pool professional or certified electrician.