9
J). CHOOSING THE POWER SOURCE
(continued)
Connecting the control box to the pump motor
Disconnect the back plate to the motor where the electrical connections are. You
will notice two connections where the power source comes in and is connected.
Connect the
Aqua Elite 50’s
power cable (black, white and green) to the same as
the motor's connections. If connected properly, the unit should come on and off
with the motor.
K). CONNECTING THE ELECTRODE CABLE
Using the Electrode Wire Assembly, connect the two terminal ends to the connectors on each side of the
electrode's connectors by first unscrewing the nuts and then tightening them back on. IT DOES NOT MATTER
WHICH END GETS CONNECTED. Then connect the bare ends to the terminal posts coming out of the power
box. IT DOES NOT MATTER IF YOU ARE CONNECTING TO THE RED OR BLACK POST.
Terminal
ends