F). INSTALLING THE ELECTRODE
Generously wrap Teflon tape around the threaded part of the electrode assembly
several times. Screw electrode into the tee. Do not over tighten.
Power Source/
Pump Timer
Pump
Electrode
POOL
Filter
Heater
Kynar check valve
¼" reinforced vinyl hose
Venturi Injector
Clear view window
2" manifold with
venturi injector and
ball valve assembly
1½" reducer bushings (if needed)
water flow
N = Nylon Hose Clamps
N
N
N
N
G). INSTALLING THE VENTURI INJECTOR
N = Nylon Hose Clamps
Mount the venturi manifold on the return line (after the filter, pump, electrode chamber, heater, etc.) so it is the
last item before entering the pool. This is very important.
MAKE SURE THE WATER FLOWS IN THE DIRECTION OF THE ARROWS MARKED ON THE
VENTURI MANIFOLD.
The venturi manifold comes in two-inch pipe. If plumbing size is 1 ½", you will need to add 2" x 1 ½" reduced
bushings on each end of the manifold (included with the venturi manifold package.)