T).  TROUBLESHOOTING 

(continued)

Can't Obtain the Proper Copper-Ion Level 

(continued)

4.)  Total Disolved Solids (TDS) is too low.  

If your pool has brand new water in it, and you are unable to obtain a 

desirable reading on the control unit, chances are the TDS level is too low.  Usually, the total dissolved solids should be 

between 300-2000 ppm.

, and tested once a year. For the system to perform on maximum capabilities (a pool with very 

warm water or a pool that is close to the maximum number of gallons rated for the system), the TDS needs to be at least 
500 ppm. If installing the unit on a brand new pool, you may need to have to raise the total dissolved solids level. THIS IS 
ONLY NECESSARY IF YOU ARE UNABLE TO OBTAIN THE DESIRED COPPER-ION LEVEL. First, determine the 
TDS level. To raise the TDS level, you need to add 1 pound of regular table salt to increase the TDS by 12 ppm per 
10,000 gallons. Once the TDS level has reached 300 ppm you will be all set, because the TDS level always raises. 

If the TDS is over 2,000, you should partially drain and refill with fresh water. This is standard pool water chemistry. If 
the unit is being installed on a salt-water pool, the unit will work fine without any adjustments.

5.)  Improper test kit readings. 

Make sure you follow the proper Ion-Test kit procedures.  Many people look at the side 

of the test tubes instead of looking  down from the top.  Also, be sure to wait three minutes for the reagents to develop.  
These reagents should be replaced yearly and kept out of direct sunlight and stored at normal room temperature.  Failure 
to do so will cause faulty readings.  Never let the reagents freeze or be exposed to extreme heat.

6.)  Improper pH readings

   This is usually the main reason for a low copper-ion level.  Make sure the pH is maintained 

between 7.2- 7.6 , with the lower end preferred.  When the pH goes over 7.8, the ions fall out of solution.  Make sure your 
test kit is updated with fresh reagents and kept out of direct sunlight and in normal room temperatures.  Never mix 
different manufacturer's reagents with the test kit.

7.)  Too much chlorine in the pool   

If the pool was just shocked with a lot of chlorine, this can give you an improper test 

kit reading on the Ion Test Kit.  The high chlorine level will "bleach" out the reading and appear to read zero. 

8.)  Sequestering Agents or Metal Out Removers in the water   

Sometimes pool owners will add a flocking or 

sequestering agent to the water to remove stains or scaling in a pool or remove undesired minerals that are in the source 
water.  Some of these will interfere with the 

Aqua Elite 50’s

 ions such as Sequasol, Cop-Out, Metal Magnet, Aluminum 

Sulfate or Alum.  Products that won't cause problems and that are actually recommended to use with 

Aqua Elite 50 

include Pool Stain Treat by 

United Chemical

 or 

Jack's Magic

.  All polymer based products like Super Blue and Sea-Klear 

do not cause problems either.  If you are unsure if a sequestering agent is causing a low ion level, send 

Clearwater 

Enviro Technologies

 a water sample to test.  If it is a problem (these agents can stay in the water for up to a year) add a 

lot of chlorine to shock it out of the pool water.

9.)  Steel plumbing   

Never install the electrodes on steel piping.  Cut out a section of this and replace with PVC pipe.

10.)  Improper installation   

Sometimes installers will mount the electrodes on a bypass line and not on the actual return 

line that goes back to the pool's water.  Make sure unit is installed properly with correct connections.

11.)  High Phosphate level

    A high phosphate level will be a breeding ground for algae.  If you have a lot of algae 

growing and can't keep the Ion-level up, you may have a high phosphate level.  Any reading over 125 ppb can cause 
problems.  Have your pool store test for phosphates or contact your dealer or 

Clearwater

 for more information.  There are 

products available that will remove phosphates from the water quickly and will eliminate algae and low Ion readings.

17

Questions?  Contact your dealer or contact us at:

1-800-756-7946 (SWIM)  •  ClearwaterPoolSystems.com

Lifetime Support

Содержание AQUA ELITE 50

Страница 1: ...Licensed technology Licensed technology Residential Pools INSTALLATION POOL CARE MANUAL MODEL AQUA ELITE 50 The Healthy Alternative to Chlorine ...

Страница 2: ... with your test kit for the amount to add Calcium Hardness The calcium hardness level should be between 150 350 ppm If the reading is well over that the pool should be partially drained and refilled with fresh water If the reading is under that chances are the pool was filled with softened water Calcium chloride should be added to the pool 1 1 4 lbs will raise the calcium hardness by 10 ppm per 10...

Страница 3: ...sted below 3 Test Kit 1 CLA 41 Electrode 1 CLE 02 Electrode Wire Assembly 1 Aqua Elite 50 User Manual 1 Aqua Elite 50 Quick Chart 1 Aqua Elite 50 Warranty Card 1 2 Flow Cell Chamber 1 2 to 1 1 2 Reducers 2 OZ VIM Venturi Injection Kit with manifold 4 Piece Molly Set with 10 Screws AE 50 Control Unit 1 ...

Страница 4: ...e a space for the electrode flow cell tee the 2 slip slip threaded tee The tee should be installed after the pump and either before or after the filter After the filter is preferred but it will work fine if installed before the filter NEVER INSTALL THE TEE NEXT TO THE POOL S HEATER 2 Turn off the pump and close all valves Disconnect all sources of power going to the timer or pump 3 Using a hacksaw...

Страница 5: ...y 1 reducer bushings if needed water flow N Nylon Hose Clamps N N N N G INSTALLING THE VENTURI INJECTOR N Nylon Hose Clamps Mount the venturi manifold on the return line after the filter pump electrode chamber heater etc so it is the last item before entering the pool This is very important MAKE SURE THE WATER FLOWS IN THE DIRECTION OF THE ARROWS MARKED ON THE VENTURI MANIFOLD The venturi manifold...

Страница 6: ...LLED CORRECTLY YOU WILL SEE AIR BUBBLES ENTER THE CLEAR PVC PIPE THESE KYNAR CHECK VALVES AND TUBING WILL WEAR OUT OVER TIME AND YEARLY REPLACEMENT IS STRONGLY RECOMMENDED SEE SECTION Q OF THIS MANUAL FOR DETAILS DO NOT SUCK ON THE ID TUBING WHEN CONNECTED TO THE OZONE SYSTEM DO NOT LOOK DIRECTLY AT THE OZONE BULB EXPOSED OUT OF THE METAL ENCLOSURE OR RISK SERIOUS INJURY Cut the hose at the areas ...

Страница 7: ...n 6 feet of the electrical source and 10 feet of the electrode flow cell tee and within 8 feet of the venturi injector It is strongly recommended to add a protective shade cover to keep the unit out of direct sunlight if possible 7 The Healthy Alternative to Chlorine ...

Страница 8: ...t either the white wire or the black wire to the LOAD side on the timer box It makes no difference which colored wire goes to the two load screws Connect the green wire to ground When installed properly the unit should come on and off when the pool pump goes on and off TO R 50 CONTROL BOX TO R 50 CONTROL BOX I ELECTRICAL Any electrical connections should be performed by a certified electrician in ...

Страница 9: ... as the motor s connections If connected properly the unit should come on and off with the motor K CONNECTING THE ELECTRODE CABLE Using the Electrode Wire Assembly connect the two terminal ends to the connectors on each side of the electrode s connectors by first unscrewing the nuts and then tightening them back on IT DOES NOT MATTER WHICH END GETS CONNECTED Then connect the bare ends to the termi...

Страница 10: ...ou will also be able to hear a noise at the venturi injector and visually see some small bubble action coming out of the closest return line and possible other in the pool Adjust the ball valve back until no bubbles and readjust until bubbles just appear and leave the ball valve set at this setting This bubble no bubble adjustment can be as sensitive as 1 16 to rotation after rough audible or visu...

Страница 11: ...on T Troubleshooting on pages 16 17 In order to get the desired reading of 0 15 to 0 20 quickly you will need to set the unit to its maximum current output 11 Other factors that affect the level ions are produced are keeping the pH under 7 8 the number of hours the filter runs and the setting of the unit Other factors include water temperature and the amount of algae bacteria already in the water ...

Страница 12: ...hile in Florida it may be 3 A 20 000 gallon pool may need a reading of 4 or 5 A 50 000 gallon pool may need a reading of 7 or 8 This is also based on running the system 8 hours a day It is all proportionate So if the pool ran 24 hours a day the settings would be 1 3 that When you lower your setting it is best to test on a daily basis If the readings continue to go up lower the setting and retest t...

Страница 13: ...let in the skimmer for continuous oxidizing The reading will be so low that it won t be detectable This is ideal for pools with heavy swimmer use orifthehomeownerisawayoften WARNING Excessive amounts of Copper may cause staining of pool and spa surfaces Always keeppHunder7 8 atalltimes O CLEANING AND OR REPLACING ELECTRODE The only part of the Aqua Elite 50 that will need maintenance or replacemen...

Страница 14: ...g Plumbing Issues Minor adjustment of the ball valve when installing the manifold may be required to divert water through the injector This may be true with two speed or variable speed pumps Older versions of these adjustable speed pumps do not adjust well and you will need to adjust the ball valve to accommodate flow through the venturi on low speed There is an internal check valve in the venturi...

Страница 15: ...n the bulb clamp Be careful NOT to break the bulb 5 Carefully pull the bulb from the white connectors and the bulb clamp from holding them in place and remove Be careful NOT to break the bulb Dispose of bulb properly after removal 6 Snap new bulb in place Secure with the metal brackets 7 Push metal plate back into its place inside the unit There is no need to add another zip tie as this was used f...

Страница 16: ...filter is clean Usually cloudy water is from a poor filtering system Make sure you oxidize on a timely basis Never add granular chlorine without dissolving it first or pouring it directly into the skimmer Can t Obtain the Proper Copper Ion Level If you are unable to obtain the proper ion level check all of the following factors to solve the problem 1 High algae growth and cloudy water Ion level to...

Страница 17: ...nts and kept out of direct sunlight and in normal room temperatures Never mix different manufacturer s reagents with the test kit 7 Too much chlorine in the pool If the pool was just shocked with a lot of chlorine this can give you an improper test kit reading on the Ion Test Kit The high chlorine level will bleach out the reading and appear to read zero 8 Sequestering Agents or Metal Out Removers...

Страница 18: ...chandise Authorization number from Clearwater Enviro Technologies Inc The Healthy Alternative to Chlorine Manufactured by Established 1989 Contact customer service see contact info above Remove Control box from wall and return to Clearwater Enviro Technologies 8767 115th Ave Largo FL 33773 The RMA number must be clearly marked on the outside of the package Include a note inside the package with th...

Страница 19: ...jected into the pool by a vacuum venturi injector to oxidize materials in the water Ozone Output 1 26 ppm ozone concentration independent 3rd party testing VUV Lamp Estimated 9 000 hour life span Electrical Specifications INPUT VOLTAGE 110 240 VAC 50 60 Hz INPUT CURRENT 1 A MAX 110VAC INPUT POWER 25 W MAX IONIZER OUTPUT VOLTAGE 24V DC IONIZER OUTPUT CURRENT Adjustable in 12 increments from 0 to 40...

Страница 20: ...Free 800 756 7946 SWIM 04 19 The Healthy Alternative to Chlorine MineralPURE The Healthy Alternative to Chlorine Manufactured by Sustainable Solutions for Our Future Licensed technology Licensed technology TM OzoneMAX 3 Vacuum ultraviolet Ozone System ...

Отзывы: