24
Revision date: 02.07.12
CLEARSPAN
™
POLY BUILDINGS
SHELTER CARE AND MAINTENANCE
Proper care and maintenance of your High Boy building is
important. Check the following items periodically to properly
maintain your shelter:
• Regularly check the main cover and end panels (if
equipped) to see that these remain tight and in proper
repair.
• Check connections, straps, ratchets and all fasteners to
verify that they remain tight.
• Do not climb or stand on the shelter at anytime.
• Remove debris and objects that may accumulate on
the shelter. Use tools that will not damage the cover
when removing debris.
• Remove snow to prevent excess accumulation. Use
tools that will not damage the cover when removing
snow.
• Check the contents of the shelter to verify that
nothing is touching the cover or the end panels (if
equipped) that could cause damage.
• Check the anchoring system to ensure that all
components are tight and in good repair.
• If the shelter is moved, inspect all parts and
connections before reassembling.
• For replacement or missing parts, call 1-800-245-9881
for assistance.
NOTE:
With the exception of Truss Arch buildings,
ClearSpan™ shelters and greenhouses
do not have any
tested loading criteria.
TIGHTEN THE SIDE RATCHETS
Side ratchets are tightened
after
the cover is stretched from
end-to-end. Before continuing, verify that the cover is in the
desired position and centered on the frame. (Loosen and
reposition if needed.) Continue with these steps to tighten
the side ratchets.
1. Move to the side ratchets attached to each leg of one
rafter. Begin at an inside rafter near the center of the
frame.
2. With an assistant at one side ratchet and someone at
the other side ratchet on the same rafter, tighten the
ratchets to secure the cover.
Tightening the ratchets at the same time on the same
rafter helps keep the cover centered and results in a
more uniform appearance.
3. Move to another rafter and repeat the steps to tighten
the side ratchets attached to that rafter.
NOTE:
If the strap builds up in the ratchet, loosen the
ratchet, remove some of the strap, and retighten.
4. After all side ratchets are tight, position someone at
each ratchet attached to the end rafter where the
bonnet straps of the cover were previously inserted.
5. Tighten the end ratchets to secure the bonnet portion of
the main cover.
6. Move to the other end of the building and secure the
bonnet at that end.
7. Read the note and information that follows.
Photo shows the ratchet
attached to the end rafter.
This ratchet is used to
secure the bonnet portion
of the main cover.
Bonnet of Main
Cover
INSTALLATION OF OPTIONAL END WALL AND PANEL
Optional end walls and end panels are available for the
High Boy building.
(Additional purchase required.)
If the
building is equipped with an end wall and end panel, loosen
the bonnet portion of the main cover and pull it back and off
of the end rafter at the end of the frame where the end wall
and panel are to be installed.
Do not remove strapping of
the main cover.
After installing the end wall and panel as instructed, pull
the bonnet back into position and secure it as previously
described.
Reposition the ratchets for the main cover bonnet as shown
in the instructions sent with the optional end wall.
Содержание 106786
Страница 26: ...26 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS FRONT PROFILE ...
Страница 27: ...27 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS CONNECTIONS ...
Страница 29: ...29 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS E2 1 0 CABLE DETAILS FALB08B FAMA40B FAG405B ...
Страница 30: ...30 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS BASE DETAILS ...
Страница 31: ...31 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106786 ...
Страница 32: ...32 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106787 ...
Страница 33: ...33 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106788 CABLE ENDS HERE ...
Страница 34: ...34 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106789 ...
Страница 35: ...35 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106790 ...
Страница 36: ...36 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106791 ...
Страница 37: ...37 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS THIS PAGE RESERVED FOR CUSTOMER NOTES ...