12
Revision date: 02.07.12
CLEARSPAN
™
POLY BUILDINGS
INSTALL ANGLED BRACES FOR THE FRAME
The angled braces provide additional support for the
end rafters. This bracing is installed in three (3) locations
between the end rafter and the first inside rafter
at each
end of the assembled frame
. The parts needed to install
the angled braces are the same
regardless of the building
length.
Part Number
Quantity
HBT166AB10 (angled brace: 110")
6
FAH317B (5/16" x 1-1/2" carriage bolts)
12
FALB32B (5/16" nut)
12
106734 (1.66" tension band)
12
FA4482B (Tek screws: #14 x 1-1/2")
24
Required tools:
• Adjustable pliers to install tension bands
• 100441 nut setter (included) for Tek screws
• Wrenches to tighten 5/16" nuts
• Lift to reach the brace locations
Complete these steps to install the tension bands and to
attach the angled braces:
1. Locate two (2) 106734 tension bands and one (1)
HBT166AB10 angled brace (110") and move to one of
the locations between the end rafter and inside rafter
shown below.
2. Place the tension bands over the lateral brace at that
location. Use adjustable pliers to squeeze the clamp
back together once it is placed around the brace.
NOTE:
Consult the diagrams in the Quick Start Guide
section of these instructions for additional information
and details.
11. Verify that the second rafter will stay in position and
that a nut and washer are installed on each of the studs
(straight tubes) to hold the lateral braces in place.
NOTE:
These nuts should remain loose so they can
be removed when the next set of lateral braces are
installed.
12. Lift the next rafter and repeat the necessary steps to
set it in place.
13. Select another set of lateral braces and the 1/2" nuts
and lock washers and install the braces between this
set of rafters.
NOTE:
The flattened ends of the lateral braces will
overlap each other when placed over the studs of
all
inside rafters
. Consult the Quick Start Guide diagrams
for additional views and details.
14. Move to the second rafter and tighten all nuts to secure
the lateral braces to that rafter.
15. Repeat the steps to install the remaining rafters and
lateral bracing for the frame assembly.
NOTE:
To protect the cover when it is installed, set
the final end rafter so that the bolt heads at each tube
splice face to the outside of the frame.
16. When the frame is assembled and all lateral braces are
secured in place, continue with the installation of the
angled braces.
10. Return to the end rafter and tighten all nuts to secure
the lateral bracing to the end rafter.
Do not remove the
temporary bracing of the first end rafter until additional
rafters are set in position.
Lateral Brace
Lateral Brace
Straight Tube
of Inside Rafter
Welded Stud
ATTENTION:
The total number of lateral braces attached
between the end rafter and the first inside
rafter is ten (10);
seven (7) are secured between the straight tubes of the
rafters and three (3) are secured to underside of the curved
rafter tubes.
See the Front - Profile diagram (Quick Start).
These are the locations of
the double lateral braces
installed earlier at each end
of the assembled frame.
Install an angled brace in
each of these locations at
each end of the frame.
ASSEMBLE FRAME (CONTINUED)
Содержание 106786
Страница 26: ...26 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS FRONT PROFILE ...
Страница 27: ...27 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS CONNECTIONS ...
Страница 29: ...29 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS E2 1 0 CABLE DETAILS FALB08B FAMA40B FAG405B ...
Страница 30: ...30 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS BASE DETAILS ...
Страница 31: ...31 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106786 ...
Страница 32: ...32 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106787 ...
Страница 33: ...33 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106788 CABLE ENDS HERE ...
Страница 34: ...34 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106789 ...
Страница 35: ...35 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106790 ...
Страница 36: ...36 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106791 ...
Страница 37: ...37 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS THIS PAGE RESERVED FOR CUSTOMER NOTES ...