2-4
C
lear
C
ube M2010S User's Guide
2-4 Installing the System into a Rack
This section provides information on installing the ClearCube M2010S into a rack
unit. If the M2010S has already been mounted into a rack, you can skip ahead to
Sections 2-5 and 2-6. There are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly. The following is a guideline for
installing the system into a rack with the rack rails provided. You should also refer
to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received a total of six rack rail sections with the ClearCube
M2010S. Two of these sections secure directly to the M2010S and the third (which
actually consists of two joined sections) secures directly to the rack itself. All
screws and hardware mentioned in the installation steps should be included in the
hardware kit.
Refer to Figure 2-1 to determine which rail section gets attached to the front of the
chassis and which gets attached to the rear of the chassis. (The longer of the two
is the front section. The third rail section attaches to the rack.)
Installing the Chassis Rails
Position the front and rear chassis rail sections along the side of the M2010S mak-
ing sure the screw holes line up. Note that these two rails are left/right specific.
Screw the front chassis rail (the long piece) securely to the side of the chassis
(see Figure 2-1, step 1). There should be two screws for each side. Repeat this
procedure for the other rail on the opposite side of the chassis. Then attach the two
rear chassis rails to the chassis in the same manner, again keeping in mind that
the rails are left/right specific. (You will also need to attach the rail brackets when
installing into a telco rack.)
Locking Tabs:
Both front chassis rails and the rack rails have a locking tab, which
serves two functions. The first is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Содержание M2010S
Страница 1: ...www clearcube com M2010S Server and Chassis User s Guide ClearCube Technology Inc ...
Страница 8: ...Notes v iii T a b l e o f C o n t e n t s ...
Страница 19: ...Chapter 2 Server Installation 2 5 Figure 2 1 Installing Chassis Rails ...
Страница 21: ...Chapter 2 Server Installation 2 7 Figure 2 2 Installing the Server into a Rack ...
Страница 23: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System ...
Страница 28: ...ClearCube M2010S User s Guide 3 4 Notes ...
Страница 58: ...5 26 ClearCube M2010S User s Guide Notes ...
Страница 98: ...A 6 ClearCube M2010S User s Guide Notes ...
Страница 104: ...B 6 ClearCube M2010S User s Guide Notes ...
Страница 116: ...C 12 ClearCube M2010S User s Guide Notes ...
Страница 136: ...D 20 ClearCube M2010S User s Guide Notes ...
Страница 140: ...E 4 ClearCube M2010S User s Guide Notes ...
Страница 141: ......