background image

7-14

C

lear

C

ube M2010S User's Guide

for ITK testing. The default setting is 

Branch 1

.

Snoop Filter

Select Enabled to eliminate snoop traffic to the graphics port to greatly improve 

system performance when running graphics intensive applications. The options 
are 

Enabled

 and Disabled.

Crystal Beach Features

Select 

Enabled

 to use the Intel I/O AT (Acceleration Technology) to accelerate 

the performance of TOE devices. (Note: A TOE device is a specialized, dedicated 
processor that is installed on an add-on card or a network card to handle some 
or  all  packet  processing  of  this  add-on  card.  For  this  motherboard,  the  TOE 
device  is  built  inside  the  ESB  2  South  Bridge  chip.)    The  options  are 

Enabled

 

and Disabled.

Route Port 80h Cycles to

This feature allows the user to decide which bus to send debug information to.  The 
options are Disabled, PCI and 

LPC

High Precision Event Time

Select Yes to activate the High Precision Event Timer (HPET), which is capable 
of    producing  periodic  interrupts  at  a  much  higher  frequency  than  a  Real-time 
Clock (RTC) can in synchronizing multimedia streams, providing smooth playback 
and reducing the dependency on other timestamp calculation devices, such as 
an x86 RDTSC Instruction embedded in a CPU. The High Precision Event Timer 
is used to replace the 8254 Programmable Interval Timer.  The options for this 
feature are Yes and 

No

USB Function

Select Enabled to enable the function of USB devices 

specified.  The settings are 

Enabled

 and Disabled.

Legacy USB Support 

This setting allows you to enable support for Legacy USB devices.  The settings 
are 

Enabled

 and Disabled.

Advanced Processor Options

Access the submenu to make changes to the following settings. 

CPU Speed

This is a display that indicates the speed of the installed processor.

Frequency Ratio 

(Available when supported by the CPU.)

The feature allows the user to set the internal frequency multiplier for the CPU. 
The options are:

 Default,

 x12, x13, x14, x15, x16, x17 and x18.

Содержание M2010S

Страница 1: ...www clearcube com M2010S Server and Chassis User s Guide ClearCube Technology Inc ...

Страница 2: ... OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment...

Страница 3: ...tallation This chapter describes the steps necessary to install the M2010S into a rack and check out the server configuration prior to powering up the system If your server was ordered without processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 System Interface Refer here for details on the system interface which in...

Страница 4: ...pter 6 for detailed information on the server chassis You should fol low the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed informa tion on running the CMOS Setup Utility Appendix A BIOS POST Messa...

Страница 5: ...ane 1 4 Cooling System 1 4 1 4 Contacting ClearCube 1 6 Chapter 2 Server Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced Airflow 2 3 Mechanical Loading 2 3 Circuit Overloading 2 3 Reliable Ground 2 3 2 4 Installi...

Страница 6: ...trical Safety Precautions 4 1 4 2 General Safety Precautions 4 2 4 3 ESD Precautions 4 3 4 4 Operating Precautions 4 4 Chapter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions 5 1 Unpacking 5 2 5 2 Serverboard Installation 5 2 5 3 Connecting Cables 5 3 Connecting Data Cables 5 3 Connecting Power Cables 5 3 Connecting the Control Panel 5 3 5 4 I O Ports 5 4 5 5 Installing t...

Страница 7: ...ive Bays 6 4 SATA Drive Installation 6 5 Hard Drive Backplane 6 6 DVD ROM and Floppy Drive Installation 6 7 6 5 Power Supply 6 8 Power Supply Failure 6 8 Removing Replacing the Power Supply 6 8 Chapter 7 Advanced Serverboard Setup 7 1 Introduction 7 1 7 2 Running Setup 7 2 7 3 Main BIOS Setup 7 2 7 4 Advanced Setup 7 7 7 5 Security 7 24 7 6 Boot 7 25 7 7 Exit 7 26 Appendix A BIOS POST Messages App...

Страница 8: ...Notes v iii T a b l e o f C o n t e n t s ...

Страница 9: ...s One 1 DVD ROM drive Two 2 3 5 dummy drive trays One 1 DVD ROM drive One 1 front control panel cable One 1 rail set SATA Accessories One 1 SATA backplane One 1 2 ft SATA cable Two 2 35 mm SATA cables Two 2 48 cm SATA cables One 1 70 cm SATA cable Two 2 SATA SGPIO cables Eight 8 SATA hot swap drive carriers The chassis has eight carriers but only six SATA drives are supported Chapter 1 Introductio...

Страница 10: ...d requires modules of the same size and speed to be installed two at a time See Chapter 5 for details Serial ATA A SATA controller is integrated into the ESB2 South Bridge portion of the 5400 chipset to provide a six port 3 Gb s Serial ATA subsystem which is RAID 0 1 10 and 5 supported The Serial ATA drives are hot swappable units Note The operating system you use must have RAID support to enable ...

Страница 11: ...omote system health include onboard voltage moni tors a chassis intrusion header auto switching voltage regulators chassis and CPU overheat sensors virus protection and BIOS rescue 1 3 Server Chassis Features The following is a general outline of the main features of the server chassis System Power The M2010S chassis features a redundant 700W power supply composed of two separate power modules Thi...

Страница 12: ...ckmount configuration The I O backplane provides seven low profile PCI expansion slots one COM port a parallel port a VGA port two USB 2 0 ports PS 2 mouse and keyboard ports and two gigabit Ethernet ports Cooling System The chassis has an innovative cooling design that includes three 8 cm hot plug system cooling fans located in the middle section of the chassis An air shroud channels the airflow ...

Страница 13: ...1 5 Chapter 1 Introduction Figure 1 1 Intel 5400 ESB2 Chipset System Block Diagram Note This is a general block diagram Please see Chapter 5 for details FBD DIMM FBD DIMM FBD DIMM FBD DIMM ...

Страница 14: ...ting ClearCube Headquarters Address The ClearCube Building 8834 Capital of Texas Highway North Austin Texas 78759 Telephone 1 512 652 3400 Toll free 1 866 652 3400 E mail support clearcube com Technical Support Web site http support clearcube com ...

Страница 15: ... a suitable location for the rack unit that will hold the ClearCube M2010S It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Read the Rack and Server Precau tions in the next section 2 3 Preparing for Setup The box the ClearCube M2010S was...

Страница 16: ...s make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the rack before you install the rails Install the heaviest server compone...

Страница 17: ...ed Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration o...

Страница 18: ...o the front of the chassis and which gets attached to the rear of the chassis The longer of the two is the front section The third rail section attaches to the rack Installing the Chassis Rails Position the front and rear chassis rail sections along the side of the M2010S mak ing sure the screw holes line up Note that these two rails are left right specific Screw the front chassis rail the long pi...

Страница 19: ...Chapter 2 Server Installation 2 5 Figure 2 1 Installing Chassis Rails ...

Страница 20: ...sis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting See Figure 2 2 When the server has been pushed completely into the rack you should hear the locking tabs click Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack Installin...

Страница 21: ...Chapter 2 Server Installation 2 7 Figure 2 2 Installing the Server into a Rack ...

Страница 22: ...he server Checking the Components and Setup You may have one or two processors already installed into the serverboard Each processor needs its own heat sink See Chapter 5 for instructions on processor and heat sink installation Your M2010S server system may have come with system memory already installed Make sure all DIMMs are fully seated in their slots For details on adding system memory refer t...

Страница 23: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System ...

Страница 24: ...em Depending upon your system s configuration your system may have one or more drives already installed If you need to install SATA drives please refer to Chapter 6 Checking the Airflow Airflow is provided by four 8 cm center chassis cooling fans An air shroud is also included in the system to maximize airflow The system component layout was carefully designed to direct sufficient cooling airflow ...

Страница 25: ...fic components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons The two push buttons located on the front of the chassis are in order from left to right a reset button and a power on off button Reset Use the reset button to reboot the system Power This is the main power button which is used to apply or turn off the main system power Turning off system power with th...

Страница 26: ... the power supply This LED should be off when the system is operating normally Overheat Fan Fail When this LED flashes it indicates a fan failure When on continuously it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating no...

Страница 27: ...r 6 for instructions on replacing failed SATA drives Red The red LED to indicate an SATA drive failure If one of the SATA drives fails you should be notified by your system management software Please refer to Chapter 6 for instructions on replacing failed SATA drives HDD Indicates IDE channel activity On the ClearCube M2010S this LED indicates SATA and or DVD ROM drive activity when flashing Power...

Страница 28: ...ClearCube M2010S User s Guide 3 4 Notes ...

Страница 29: ...er you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits another person who is familiar with the power off controls should be nearby to switch off the power if neces sary Use only one hand when working with powered on electrical equipment This is to avoid mak...

Страница 30: ...dy which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Serverboard Battery CAUTION There is a danger of explosion if the onboard battery is installed upside down which will reverse its polarities see Figure 4 1 This battery must be replaced only with the same or an equivalent type rec...

Страница 31: ... use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid touching their pins Put the serverboard an...

Страница 32: ...re that the chassis cover is in place when the M2010S is operating to assure proper cooling Out of warranty damage to the system can occur if this practice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER BATTERY HOLDER LITHIUM BATTERY OR ...

Страница 33: ... to handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent Electrostatic Discharge ESD Touch a grounded metal object before removin...

Страница 34: ...from the back lip of the top cover of the chassis then pull the cover off The M2010S serverboard requires a chassis big enough to support a 13 68 x 13 05 serverboard Make sure that the I O ports on the serverboard align properly with their respective holes in the I O shield at the back of the chassis Carefully mount the serverboard to the serverboard tray by aligning the board holes with the raise...

Страница 35: ...I SATA5 Control Panel cable JF1 DVD ROM drive cable IDE 1 USB cable USB2 3 COM Port cable COM2 Important Make sure the cables do not come into contact with the fans Connecting Power Cables The M2010S serverboard has a 24 pin primary power supply connector JPW1 for connection to the ATX power supply In addition there is a 4 pin secondary power connector JPW2 as well as an 8 pin processor power conn...

Страница 36: ...ors and locations of the various I O ports Figure 5 1 Control Panel Header Pins Mouse Green Keyboard Purple COM1 Port Turquoise VGA Port Blue Figure 5 2 I O Ports NMI x Key Vcc Vcc Vcc Vcc Vcc Vcc Reset Button Power Button Ground x Key Power On LED HDD LED NIC1 LED NIC2 LED OH Fan Fail LED Power Fail LED Ground Ground 2 1 20 19 USB0 1 Ports LAN1 2 Ports ...

Страница 37: ...ways connect the power cord last and remove it before adding remov ing or changing any components Make sure to install the processor into the CPU socket before you install the CPU heat sink Intel s boxed Xeon CPU package contains the CPU fan and heat sink assembly If you buy the CPUs separately use only Intel certified heat sinks and fans Make sure to install the heat sink backplate and the server...

Страница 38: ...umb and your index finger to hold the CPU at opposite sides Align pin1 of the CPU the corner marked with a triangle with the notched corner of the CPU socket Find the corner of the CPU that has a semi circle cutout below a gold dot CPU key This corner should be aligned with the cutout on the socket socket key Once aligned carefully lower the CPU straight down into the socket Do not drop the CPU on...

Страница 39: ...thumb to gently push the load lever down until it snaps into the retention clasp If the CPU is properly installed into the socket the PnP cap will be automatically released from the load plate when the lever locks Remove the cap Repeat steps to install a second CPU if desired Warning Keep the plastic PnP cap The serverboard must be shipped with the PnP cap properly installed to protect the CPU soc...

Страница 40: ... the heat sink However if you do need to uninstall the heat sink please follow these instructions to avoid damaging the CPU or the CPU socket Installation and Removal of the Heat Sink Uninstalling the Heat Sink Unscrew and remove the heat sink screws in the sequence shown in the picture on the right Hold the heat sink as shown in the picture on the right and gently move back and forth to loosen it...

Страница 41: ... installation Installing Memory Modules Insert the desired number of Fully Buffered DDR2 modules into the memory slots starting with DIMM 1A To enhance memory performance install pairs of memory modules of the same type and of the same beginning with DIMM 1A and DIMM 2A then DIMM 3A and DIMM 4A and so on see Memory Configuration Table below Insert each DIMM module vertically into its slot Pay atte...

Страница 42: ...cards one PCI Ex press x4 card in a x8 slot two PCI X 133 100 MHz cards and one UIO card All cards must be low profile Installing an Add on Card Begin by removing the shield for the PCI slot you wish to populate Fully seat the card into the slot pushing down with your thumbs evenly on both sides of the card Finish by using a screw to secure the top of the card shield to the chassis The PCI slot sh...

Страница 43: ...Chapter 5 Advanced Serverboard Setup 5 11 Figure 5 4 M2010S Serverboard Layout not drawn to scale 5 8 Serverboard Details ...

Страница 44: ...ers Floppy Floppy Disk Drive Connector IDE1 IDE2 IDE Drive Compact Flash Card Connector I SATA0 I SATA5 SATA Ports J3P PWR Supply Fail LED JAR Alarm Rest Header JD1 Onboard Speaker Power LED JF1 Front Panel Connector JK1 Keylock Header JL1 Chassis Intrusion Header JOH1 Overheat Warning Header JPW1 24 pin ATX Power Connector JPW2 JPW3 12V 4 Pin 12V 8 pin Power Connectors JWOL JWOR Wake On LAN Heade...

Страница 45: ...5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Power Button Pin Definitions JF1 Pin Definition 1 PW_ON 2 Ground Secondary Power Connector JPW2 must also be connected to the power supply See the table on the right for pin definitions Main ATX Power Supply Connector The primary power supply con...

Страница 46: ...efinitions JF1 Pin Definition 13 Vcc 14 HD Active NIC2 JLAN2 LED The LED connections for JLAN2 are on pins 9 and 10 of JF1 Attach an LED cable to display network activ ity See the table on the right for pin definitions NIC1 LED Pin Definitions JF1 Pin Definition 11 Vcc 12 Ground NIC1 JLAN1 LED The LED connections for JLAN1 are on pins 11 and 12 of JF1 Attach an LED cable to display network activ i...

Страница 47: ...keyboard port See the table on the right for pin definitions NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer to the table on the right for pin definitions NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground Fan Header Pin Definitions FAN1 8 Pin Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWM Control PS 2 Keyboard and Mouse Port Pi...

Страница 48: ...de the VGA port on the I O backplane These ports accept RJ45 type cables Wake On Ring The Wake On Ring header is desig nated JWOR This function allows your computer to receive and be awak ened by an incoming call when in the suspend state See the table on the right for pin definitions You must also have a WOR card and cable to use this feature Wake On Ring Pin Definitions JWOR Pin Definition 1 Gro...

Страница 49: ...al Bus Pin Definitions USB USB0 1 Pin Definition USB2 3 4 Pin Definition 1 5V 1 5V 2 PO 2 PO 3 PO 3 PO 4 Ground 4 Ground 5 N A 5 Key Power LED Speaker On JD1 header pins 1 3 are for a power LED and pins 4 7 are for the speaker Close pins 4 7 with a jumper to use an external speaker If you wish to use the onboard speaker please close pins 6 7 See the table on the right for speaker pin definitions P...

Страница 50: ... is activated when a power module fails See the table on the right for pin definitions Alarm Reset Header Pin Definitions JAR Pin Setting Definition Pin 1 Ground Pin 2 5V Overheat LED Fan Fail JOH1 The JOH1 header is used to connect an LED to provide warning of chassis overheating This LED will blink to in dicate a fan failure Refer to the table on right for pin definitions Overheat LED Pin Defini...

Страница 51: ... on both pins and Open means the jumper is either on only one pin or completely removed Keylock The keyboard lock connection is designated JK1 Utilizing this header allows you to inhibit any actions made on the keyboard effectively locking it Keylock Pin Definitions JK1 Pin Definition 1 Ground 2 Keylock R N Compact Flash Card PWR Connector A Compact Flash Card Power Con nector is located at JWF1 F...

Страница 52: ...ght for jumper settings VGA Enable Disable Jumper Settings JPG1 Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled 3rd Power Fail Detect The system can notify you in the event of a power supply failure This feature is available when three power supply units are installed in the chassis with one acting as a backup If you only have one or two power supply units installed you should disable...

Страница 53: ...per JCF1 to work properly you will need to connect the Compact Flash Card power cable to JWF1 first Refer to the board layout below for the location Compact Flash Card Master Slave Select JCF1 Jumper Definition Open Slave Secondary Closed Master Primary Watch Dog Enable Disable JWD controls the Watch Dog function Watch Dog is a system monitor that can reboot the system when a software application ...

Страница 54: ...the right for jumper settings Reboot Option Jumper Settings JP1 Setting Definition Off Reboot On No Reboot Memory Voltage Select Jumper JP2 allows the user to select the memory voltage for the motherboard The default setting is Auto See the table on the right for jumper settings Memory Voltage Select Jumper Settings JP2 Setting Definition Pins 1 2 Auto Pins 2 3 1 5V Open 1 8V ...

Страница 55: ...e connection speed LED GLAN1 2 LED Connection Speed Indicator LED Color Definition Off 10 MHz Green 100 MHz Amber 1 GHz Onboard Power LED LE1 An Onboard Power LED is located at LE1 This LED Indicator is lit when the system is on Be sure to unplug the power cable before removing or adding any components See the table on the right for more details Onboard PWR LED Indicator LE1 LED Color Definition O...

Страница 56: ... your hard drive s Consult the documentation that came with your disk drive for details on actual jumper locations and settings for the hard disk drive Floppy Drive Connector The floppy connector is located at J17 See the table below for pin definitions Floppy Drive Connector Pin Definitions J17 Pin Definition Pin Definition 1 Ground 2 FDHDIN 3 Ground 4 Reserved 5 Key 6 FDEDIN 7 Ground 8 Index 9 G...

Страница 57: ...0 Key 21 DRQ3 22 Ground 23 I O Write 24 Ground 25 I O Read 26 Ground 27 IOCHRDY 28 BALE 29 DACK3 30 Ground 31 IRQ14 32 IOCS16 33 Addr1 34 Ground 35 Addr0 36 Addr2 37 Chip Select 0 38 Chip Select 1 39 Activity 40 Ground IDE Connectors There are two IDE connectors one blue and one white on the serverboard IDE 1 blue is designated as the Pri mary IDE drive The white connector is designated as the Sec...

Страница 58: ...5 26 ClearCube M2010S User s Guide Notes ...

Страница 59: ...carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avo...

Страница 60: ... from JF1 on the serverboard to JP4 on the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both JF1 and JP4 Pull all excess cabling out of the airflow path The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons Details on JF1 can be found in Chapter 5 Control Panel Main Power Slim DVD ROM Drive 3 5 Drive Bays 2 SA...

Страница 61: ...to run with a failed fan Remove the top chassis cover while the system is still running to determine which of the fans has failed Replacing System Fans Removing a fan Remove the chassis cover Press the tabs on the sides of the fan to unlock and remove the fan and its housing The fan s power connections will automatically detach System power does not need to be shut down since the fans are hot plug...

Страница 62: ...t use standard 1 high SATA drives in the ClearCube M2010S DVD ROM Floppy Disk Drive For installing removing the DVD ROM or floppy disk drive you will need to gain access to the inside of the server by removing the top cover of the chassis Proceed to the DVD ROM and Floppy Drive Installation section later in this chapter for instructions 5 25 Drive Bay For installing removing a component in the 5 2...

Страница 63: ...drive to the carrier with four screws as shown in Figure 6 3 Installing removing hot swap Serial ATA drives Push the release button located beside the drive s LEDs Swing the handle fully out and use it to pull the drive carrier straight out see Figure 6 4 Note Your OS must have RAID support to enable the hot plug capability of the SATA drives 1 2 1 2 Figure 6 3 Mounting a SATA Drive in a Carrier I...

Страница 64: ...Button Hard Drive Backplane The SATA drives plug into a backplane that provides power drive ID and bus termi nation A RAID controller can be used with the backplane to provide data security The operating system you use must have RAID support to enable the hot swap capability of the Serial ATA drives The backplane is already preconfigured so there are no jumpers or switches present on it Handle ...

Страница 65: ...e top of the chassis to release the top cover and at the same time push the cover away from you until it stops You can then lift the top cover from the chassis to gain full access to the inside of the server Note You must power down the system before installing or removing floppy or IDE components Drives mount on rails and should click into place to be correctly and fully installed in their bays T...

Страница 66: ... units have a hot swap capability meaning you can replace the failed unit without powering down the system Removing Replacing the Power Supply You do not need to shut down the system to replace a power supply unit The backup power supply module will keep the system up and running while you replace the failed hot swap unit Replace with the same model contact ClearCube Removing the power supply Firs...

Страница 67: ...s turned off a backup bat tery provides power to the CMOS Logic enabling it to retain system parameters When the computer is powered on the computer is configured with the values stored in the CMOS Logic by the system BIOS which gains control at boot up How To Change the Configuration Data The CMOS information that determines the system parameters may be changed by entering the BIOS Setup utility ...

Страница 68: ...s By pressing Delete immediately after turning the system on or When the message shown below appears briefly at the bottom of the screen during the POST Power On Self Test press the Delete key to activate the main Setup menu Press the Delete key to enter Setup 7 3 Main BIOS Setup All main Setup options are described in this section The main BIOS Setup screen is displayed below Use the Up Down arro...

Страница 69: ...te Using the arrow keys highlight the month day and year fields and enter the correct data Press the Enter key to save the data BIOS Date This field displays the date when this version of BIOS was built Legacy Diskette A This setting allows the user to set the type of floppy disk drive installed as diskette A The options are Disabled 360Kb 5 25 in 1 2MB 5 25 in 720Kb 3 5 in 1 44 1 25MB 3 5 in and ...

Страница 70: ... Select Auto to allow the BIOS to automatically configure the parameters of the HDD installed at the connection Enter a number between 1 to 39 to select a predetermined HDD type Select User to allow the user to enter the parameters of the HDD installed Select CDROM if a CDROM drive is installed Select ATAPI if a removable disk drive is installed CHS Format The following items will be displayed by ...

Страница 71: ...2 Bit I O This option allows the user to enable or disable the function of 32 bit data transfer The options are Enabled and Disabled Transfer Mode Thisoptionallowstheusertosetthetransfermode TheoptionsareStandard Fast PIO1 Fast PIO2 Fast PIO3 Fast PIO4 FPIO3 DMA1 and FPIO4 DMA2 Ultra DMA Mode This option allows the user to select Ultra DMA Mode The options are Disabled Mode 0 Mode 1 Mode 2 Mode 3 ...

Страница 72: ... item is set to Enabled the item ICH RAID Code Base will be available for you to select either Intel or Adaptec Host RAID firmware to be activated If this item is set to Disabled the item SATA AHCI Enable will be available The options are Enabled and Disabled ICH RAID Code Base Select Intel to enable Intel s SATA RAID firmware Select Adaptec to use Adaptec s HostRAID firmware The options are Intel...

Страница 73: ...ogo screen during boot up POST Errors Select Enable to stop the POST routine and allow the system to display error messages when an error occurs during bootup The options are Enabled and Disabled ACPI Mode Use the setting to determine if you want to employ ACPI Advanced Configuration and Power Interface power management on your system The options are Yes and No 7 4 Advanced Setup ChooseAdvancedfro...

Страница 74: ...om S3 S5 States Select Space to allow the user to power on the system by pressing the space bar Select Password to allow the user to enter the password to power on the system Select Disabled to disable this function Set Power On Password When Password is selected on the item above the user will be prompted to key in a password of 5 letter long to be used to power on the system Power Loss Control T...

Страница 75: ...CPU to speed up CPU operations Select Uncached to disable this function Select Write Through to allow data to be cached into the buffer and written into the system memory at the same time Select Write Protect to prevent data from being written into the base memory area of Block 0 512K Select Write Back to allow the CPU to write data back directly from the buffer without writing data to the System ...

Страница 76: ... user can achieve better graphic effects when using a Linux graphic driver that requires the write combining configuration with 4GB or more memory The options are Enabled and Disabled PCI Configuration Access the submenu to make changes to the following settings for PCI devices Onboard GLAN1 Onboard GLAN2 Gigabit LAN OPROM Configure Select Enabled to allow the system to boot from the GLAN1 connect...

Страница 77: ...master The options are Enabled and Disabled Latency Timer This setting allows you to set the clock rate for Bus Master A high priority high throughout device may benefit from a greater clock rate The options are Default 0020h 0040h 0060h 0080h 00A0h 00C0h and 00E0h For UNIX Novell and other operating systems please select the option other If a drive fails after the installation of a new software y...

Страница 78: ...nu The following items will appear VT d for Port 0 ESI VT d for Port 1 VT d for Port 3 VT d for Port 5 VT d for Port 7 VT d for Port 9 Select Enable to enable Intel VT d support for Port 0 ESI Port 3 Port 5 Port 7 Port 9 through using DRHD structures located in the ACPI Tables 4GB PCI Hole Granularity This feature allows you to select the granularity of PCI hole for PCI slots If MTRRs are not enou...

Страница 79: ...m DRAM temperature based on a predefined value The options are Enabled and Disabled AMB Thermal Sensor Select Enabled to enable the thermal sensor embedded in the Advanced Memory Buffer on a fully buffered memory module for thermal monitoring The options are Disabled and Enabled Thermal Throttle Select Enabled to enable closed loop thermal throttling on a fully buffered FBD memory module In the cl...

Страница 80: ...ect Yes to activate the High Precision Event Timer HPET which is capable of producing periodic interrupts at a much higher frequency than a Real time Clock RTC can in synchronizing multimedia streams providing smooth playback and reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instruction embedded in a CPU The High Precision Event Timer is used to replace the 82...

Страница 81: ... overheat threshold Set to Disabled to use Thermal Manager 1 TM1 allowing CPU clocking to be regulated via CPU Internal Clock modulation when the CPU temperature reaches the overheat threshold C1 Enhanced Mode Available when supported by the CPU Set to Enabled to enable Enhanced Halt State to lower CPU voltage frequency to prevent overheat The options are Enabled and Disabled Note please refer to ...

Страница 82: ... 8 bus cycles to 120 bus cycles in 8 cycle increment The default setting is 32 bus cycles Intel R Virtualization Technology Available when supported by the CPU Select Enabled to use the feature of Virtualization Technology to allow one platform torunmultipleoperatingsystemsandapplicationsinindependentpartitions creating multiple virtual systems in one physical computer The options are Enabled and ...

Страница 83: ...nd IRQ4 Serial Port B This setting allows you to assign control of serial port B The options are Enabled user defined Disabled Auto BIOS controlled and OS Controlled Mode This setting allows you to set the type of device that will be connected to serial port B The options are Normal and IR for an infrared device Base I O Address This setting allows you to select the base I O address for serial por...

Страница 84: ... select the base I O address for the Floppy port The options are Primary and Secondary DMI Event Logging Access the submenu to make changes to the following settings Event Log Validity This is a display to inform you of the event log validity It is not a setting Event Log Capacity This is a display to inform you of the event log capacity It is not a setting View DMI Event Log Highlight this item a...

Страница 85: ...00 1200 2400 9600 19 2K 38 4K 57 6K and 115 2K Console Type This item allows you to set console redirection type The options are VT100 VT100 8bit PC ANSI 7bit PC ANSI VT100 VT UTF8 and ASCII Flow Control This item allows you to select the flow control option for the console The options are None XON XOFF and CTS RTS Console Connection This item allows you to decide how console redirection is to be ...

Страница 86: ...ntrol Modes This feature allows the user to decide how the system controls the speeds of the onboard fans The CPU temperature and the fan speed are correlative When the CPU on die temperature increases the fan speed will also increase and vice versa Select Workstation if your system is used as a Workstation Select Server if your system is used as a Server Select 3 pin if your chassis uses 3 pin fa...

Страница 87: ...rface The options are Enabled and Disabled Clear System Event Logging Enabling this function to force the BIOS to clear the system event logs during the next cold boot The options are Enabled and Disabled Existing Event Log Number This item displays the number of the existing event log Event Log Control System Firmware Progress Enabling this function to log POST progress The options are Enabled an...

Страница 88: ...this option when OS Boot Watch Dog is set to Disabled Time Out Option This feature allows the user to determine what action to take in an event of a system boot failure The options are No Action Reset Power Off and Power Cycles System Event Log System Event Log List Mode These options display the System Event SEL Log and System Event SEL Log in List Mode Items include SEL System Event Log Entry Nu...

Страница 89: ...Chapter 7 BIOS 7 23 Realtime Sensor Data This feature display information from motherboard sensors such as temperatures fan speeds and voltages of various components ...

Страница 90: ...means a supervisor password has been entered User Password Is This feature indicates if a user password has been entered to the system Clear means such a password has not been used and Set means a user password has been entered Set Supervisor Password When the item Set Supervisor Password is highlighted hit the Enter key When prompted type the Supervisor s password in the dialogue box to set or to...

Страница 91: ... above are bootable devices listed in the sequence of boot order as specified The boot functions for the devices included in the candidate list above are currently disabled Use a key or a key to move the device up or down Use the f key or the r key to specify the type of an USB device either fixed or removable You can select one item from the boot list and hit the x key to remove it from the list ...

Страница 92: ...y Exit Discarding Changes Highlight this item and hit Enter to exit the BIOS Setup utility without saving any changes you may have made Load Setup Defaults Highlight this item and hit Enter to load the default settings for all items in the BIOS Setup These are the safest settings to use Discard Changes Highlight this item and hit Enter to discard cancel any changes you ve made You will remain in t...

Страница 93: ...led Keyboard controller failed test May require replacing keyboard controller Keyboard locked Unlock key switch Unlock the system to proceed Monitor type does not match CMOS Run SETUP Monitor type not correctly identified in Setup Shadow Ram Failed at offset nnnn Shadow RAM failed at offset nnnn of the 64k block at which the error was de tected System RAM Failed at offset nnnn System RAM failed at...

Страница 94: ...ous POST did not complete successfully POST loads default values and offers to run Setup If the failure was caused by incorrect values and they are not corrected the next boot will likely fail On systems with control of wait states improper Setup settings can also terminate POST and cause this error on the next boot Run Setup and verify that the waitstate configuration is correct This error is cle...

Страница 95: ...ailed ServerBIOS2 test error Cannot generate software NMI Non Maskable Interrupt Fail Safe Timer NMI Failed ServerBIOS2 test error Fail Safe Timer takes too long Device Address Conflict Address conflict for specified device Allocation Error for device Run ISA or EISA Configuration Utility to resolve resource conflict for the specified device CD ROM Drive CD ROM Drive identified Entering SETUP Star...

Страница 96: ... tested One or more I2O Block Storage Devices were excluded from the Setup Boot Menu There was not enough room in the IPL table to display all installed I2O block stor age devices Operating system not found Operating system cannot be located on either drive A or drive C Enter Setup and see if fixed disk and drive A are properly identified Parity Check 1 nnnn Parity error found in the system bus BI...

Страница 97: ... Optional message displayed during POST Can be turned off in Setup PS 2 Mouse PS 2 mouse identified Run the I2O Configuration Utility One or more unclaimed block storage devices have the Configuration Request bit set in the LCT Run an I2O Configuration Utility e g the SAC utility System BIOS shadowed System BIOS copied to shadow RAM UMB upper limit segment address nnnn Displays the address nnnn of...

Страница 98: ...A 6 ClearCube M2010S User s Guide Notes ...

Страница 99: ... error in the top left corner of the screen The following is a list of codes that may be written to port 80h Appendix B BIOS POST Codes POST Code Description 01h IPMI Initialization 02h Verify Real Mode 03h Disable Non Maskable Interrupt NMI 04h Get CPU type 06h Initialize system hardware 07h Disable shadow and execute code from the ROM 08h Initialize chipset with initial POST values 09h Set IN PO...

Страница 100: ...38h Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory for RomPilot optional 42h Initialize interrupt vectors 45h POST device initialization 46h 2 1 2 3 Check ROM copyright notice 48h Check video configuration against CMOS 49h Initialize PCI bus and devices 4Ah Initialize all video ...

Страница 101: ...and IRQs optional 81h Late POST device initialization 82h Detect and install external RS232 ports 83h Configure non MCD IDE controllers 84h Detect and install external parallel ports 85h Initialize PC compatible PnP ISA devices 86h Re initialize onboard I O ports 87h Configure Motherboard Configurable Devices optional 88h Initialize BIOS Data Area 89h Enable Non Maskable Interrupts NMIs 8Ah Initia...

Страница 102: ...ne prepare to boot operating system B4h 1 One short beep before boot B5h Terminate QuietBoot optional B6h Check password optional B7h Initialize ACPI BIOS and PPM Structures B9h Prepare Boot BAh Initialize SMBIOS BCh Clear parity checkers BDh Display MultiBoot menu BEh Clear screen optional BFh Check virus and backup reminders C0h Try to boot with INT 19 C1h Initialize POST Error Manager PEM C2h I...

Страница 103: ...type EDh Initialize Memory size EEh Shadow Boot Block EFh System memory test F0h Initialize interrupt vectors F1h Initialize Run Time Clock F2h Initialize video F3h Initialize System Management Manager F4h Output one beep F5h Clear Huge Segment F6h Boot to Mini DOS F7h Boot to Full DOS If the BIOS detects errors on 2C 2E or 30 base 512K RAM error it displays an additional word bitmap xxxx indicati...

Страница 104: ...B 6 ClearCube M2010S User s Guide Notes ...

Страница 105: ...rboard The current version of the ESB2 SATA RAID Utility can only support the Windows XP 2000 2003 Operating Systems Serial ATA SATA Serial ATA SATA is a physical storage interface that uses a single cable with a minimum of four wires to create a point to point connection between devices It is a serial link which supports transfer rates up to 3 0 Gbps Because the serial cables used in SATA are thi...

Страница 106: ...RAID Functions Native Mode 1 Press the Del key during system bootup to enter the BIOS Setup Utility Note If it is the first time powering on the system we recommend that you load the Optimized Default Settings If you have already done so please skip to Step 3 2 Use the arrow keys to select the Exit Settings Once in the Exit settings Scroll down to select Load Optimized Default Settings and press t...

Страница 107: ...s after Power On Self Test b When you see the above screen press the Ctrl and the I keys simultane ously to have the main menu of the SATA RAID Utility appear Note All graphics and screen shots shown in the manual are for reference only The screen shots shown in the manual do not imply ClearCube endorsement or non en dorsement on any 3rd party s product Your screens may or many not look exactly th...

Страница 108: ... and press Space to select it A triangle appears to confirm the selection of the drive f Use the Up Arrow Down Arrow keys to select the stripe size ranging from 4 KB to 128 KB for the RAID 0 array and hit Enter Note For a server please use a lower stripe size and for a multimedia system use a higher stripe size The default stripe size is 128 KB g Press Enter when the Create Volume item is highligh...

Страница 109: ...the previous menu c When RAID Level item is highlighted press the Up Arrow Down Arrow keys to select RAID 1 Mirror and hit Enter d When the Capacity item is highlighted enter your RAID volume capacity and hit Enter The default setting is the maximum capacity allowed e Press Enter when the Create Volume item is highlighted A warning mes sage displays f When asked Are you sure you want to create thi...

Страница 110: ...wn Arrow keys to select the stripe size from 4 KB to 128 KB for your RAID 10 and hit Enter The default setting is 64 KB Note For a server please use a lower stripe size and for a multimedia system use a higher stripe size e When the RAID Volume Capacity item is highlighted enter your RAID volume capacity and hit Enter The default setting is the maximum capacity allowed f Press Enter when the Creat...

Страница 111: ...rive and press Space to select it A triangle appears to confirm the selection of the drive f Use the Up Arrow Down Arrow keys to select the stripe size ranging from 4 KB to 128 KB for the RAID 5 array and hit Enter Note For a server please use a lower stripe size and for a multimedia system use a higher stripe size The default stripe size is 128 KB g Enter your desired RAID volume capacity and pre...

Страница 112: ...ives when deleting a RAID set a From the main menu select item2 Delete RAID Volume and press Enter b Use the Up Arrow Down Arrow keys to select the RAID set you want to delete and press Del A Warning message displays c When asked Are you sure you want to delete this volume Y N press Y to delete the RAID volume or type N to go back to the Delete Volume menu ...

Страница 113: ...set drive A Warning message displays d Press Y to reset the drive or type N to go back to the main menu Exiting the Intel Matrix Storage Manager Utility a From the main menu select item4 Exit and press Enter A warning mes sage will appear b Press Y to reset the drive or type N to go back to the main menu Warning Be cautious when you reset a RAID volume HDD to non RAID or Resetting a RAID HDD Reset...

Страница 114: ...ter key Choose the Intel R ESB2 SATA RAID Controller from the list indicated in the XP 2000 2003 Setup Screen and press the Enter key Press the Enter key to continue the installation process If you need to specify any additional devices to be installed do it at this time Once all devices are specified press the Enter key to continue with the installation From the Windows XP 2000 2003 Setup screen ...

Страница 115: ... installed To install these software programs and drivers click the icons to the right of these items Note Click the icons showing a hand writing on the paper to view the readme files for each item Click on a computer icon to the right of an item to install an item from top to the bottom one at a time After installing each item you must re boot the system before proceeding with the next item on th...

Страница 116: ...C 12 ClearCube M2010S User s Guide Notes ...

Страница 117: ...w and can be installed in smaller chassis In addition the cables used in PATA can only extend to 40cm long while SATA cables can extend up to one meter Overall SATA provides better functionality than PATA ESB2 I O Controller Hub Located in the South Bridge of the Intel 5400 chipset the ESB2 I O Controller Hub provides the I O subsystem with access to the rest of the system It supports a 1 channel ...

Страница 118: ...ault settings for the BIOS 3 Use the arrow keys to select the Main section in BIOS 4 Scroll down to SATA Control Mode and press the Enter key to select Enhanced 5 Scroll down to SATA RAID Enabled and press Enter Then select En abled 6 Scroll down to ICH RAID Codebase and select Adaptec Then press En ter For ICH RAID Codebase Change the setting from Intel to Adaptec 7 Go to Exit Select Exit Saving ...

Страница 119: ...ec RAID Configuration Utility ARC The Adaptec RAID Configuration Utility an embedded BIOS Utility includes the following Array Configuration Utility Use this utility to create configure and manage ar rays Disk Utilities Use this option to format or verify disks To run the Adaptec RAID Configuration Utility you will need to do the following 1 Enable RAID functions in the system BIOS refer to Chapte...

Страница 120: ...S User s Guide Managing Arrays Select this option to view array properties and configure array settings To select this option using the arrow keys and the enter key select Managing Arrays from the main menu as shown above ...

Страница 121: ... may make any data on the disk inaccessible If the drive is used in an array you may not be able to use the array again Do not configure a disk that is part of a boot array To determine which disks are associated with a particular array please refer to Viewing Array Properties To configure a disk drive 1 From the main menu shown on Page D 4 select Configure Drives and hit Enter as shown below ...

Страница 122: ...es you want to configure and press Insert 3 The drive you ve selected will appear in the Selected Drives Dialog Box on the right as shown below Repeat the same steps until all drives that you want to configure appear in the selected drives box 4 Once both drives display in the selected drive box press Enter ...

Страница 123: ...Appendix D Adaptec HostRAID D 7 5 Read the warning message as shown in the screen below 6 Make sure that you have selected the correct disk drives to configure If cor rect type Y to continue ...

Страница 124: ... is recommended that you configure devices before you create arrays To create an array 1 From the main menu shown on page D 4 select Create Array 2 Select the disks for the new array and press Insert as the screen shown below Note To de select any disk highlight the disk and press Delete 3 The arrays you have selected will appear on the Selected Drives dialog box on the right as shown below 4 Pres...

Страница 125: ...fault setting 4 The item Create RAID via allows you to select between the different ways of creating methods for RAID 0 and RAID 1 The following table gives examples of when each is appropriate Note If you select Migrate for RAID 0 or Build for RAID 1 you will be asked to select the source drive The contents of the source drive will be preserved However the data on the new drive will be lost Raid ...

Страница 126: ...sizes in a RAID However you can only select a smaller drive as the source or first drive during a build operation 5 When migrating from single volume to RAID 0 migrating from a larger drive to a smaller drive is allowed However the destination drive must be at least half the capacity of the source drive 6 It is not recommended that you migrate or build an array on Windows dynamic disks volumes bec...

Страница 127: ...terisk will appear next to the bootable array as shown in the picture below Deleting a Bootable Array To delete a bootable array 1 From the Main menu select Manage Arrays 2 From the List of Arrays select the bootable array you want to delete and press Ctrl and B Note a bootable array is the array marked with an asterisk as shown in the picture above 3 When the following message is displayed The ar...

Страница 128: ... and press Insert and then press Enter 3 Press Yes when the following prompt is displayed Do you want to create spare Yes No The spare you have selected will appear in the Selected drives Menu To delete a Hotspare 1 From the main menu shown on Page D 4 select Add Delete Hotspares 2 Use the up and down arrow keys to highlight and select the Hotspare you want to delete and press delete and then pres...

Страница 129: ...nd hit Enter as shown on the previous page 2 From the List of Arrays dialog box shown below select the array you want to view and press Enter The Array Properties dialog box appears as shown below showing detailed information on the array The physical disks associated with the array are dis played here 3 Press Esc to return to the previous menu ...

Страница 130: ... Rebuild to restore its functionality For a critical array rebuild operation the optimal drive is the source drive Note 2 If no spare array exists and a hard disk drive fails you need to create a spare before you can rebuild an array To Rebuild an array 1 From the Main Menu select Manage Arrays as shown in the screen below From the List of Arrays select the array you want to Rebuild 2 Press Ctrl a...

Страница 131: ...e and press delete 3 In the Array Properties dialog box select Delete and press Enter The fol lowing prompt is displayed Warning Deleting the array will render array unusable Do you want to delete the array Yes No RAID 1 only the following prompt is also displayed Deleting the partition will result in data loss Do you also want to delete the parti tion Yes No 4 Press Yes to delete the array and pa...

Страница 132: ...to format or verify the media of your Serial ATA hard disks To access the disk utilities 1 From the Adaptec RAID Configuration Utility Menu select Disk Utilities as shown above and press Enter The following screen appears 2 Select the desired disk and press Enter The following screen appears ...

Страница 133: ...factory and do not need to be low level formatted again 3 When the screen shown below displays select Format Disk and press Enter The following screen appears 4 Read the warning message when it appears in the screen as shown below To continue with disk formatting select Yes and hit Enter Otherwise select No and press Enter Caution Formatting a disk destroys all data on the drive Be sure to back up...

Страница 134: ...hen the screen shown above displays select Verify Disk Media and press Enter 4 A message will display indicating that the selected drive will be scanned for media defects Select Yes and hit Enter to proceed with disk verifying other wise select No and hit Enter ...

Страница 135: ...ndix D Adaptec HostRAID D 19 To Exit Adaptec RAID Configuration Utility 1 Once you have completed RAID array configurations press ESC to exit The following screen will appear 2 Press Yes to exit the Utility ...

Страница 136: ...D 20 ClearCube M2010S User s Guide Notes ...

Страница 137: ...B of FBD ECC DDR2 800 667 533 SDRAM Both 1 5V and 1 8V memory are supported Note Interleaved memory requires memory must be installed four modules at a time See Section 5 6 for details SATA Controller Intel on chip ESB2 controller for 6 port 3 Gb s SATA RAID 0 1 supported SATA Drive Bays Eight hot swap drive bays to house six 6 standard SATA drives Peripheral Drive Bays One slim DVD ROM drive Expa...

Страница 138: ...ng 3431 BTUs hr for rated output power of 700W Operating Environment Operating Temperature 10º to 35º C 50º to 95º F Non operating Temperature 40º to 70º C 40º to 158º F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnet...

Страница 139: ...Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate ...

Страница 140: ...E 4 ClearCube M2010S User s Guide Notes ...

Страница 141: ......

Страница 142: ...www clearcube com ClearCube Technology Inc 8834 Capital of Texas Highway North Austin Texas 78759 voice 512 652 3500 PN G0400058 ...

Отзывы: